Cargando…

Cook–Swartz Doppler Probe Surveillance for Free Flaps—Defining Pros and Cons

Introduction  The main postoperative complication of free flaps is perfusion compromise. Urgent intervention is critical to increase the chances of flap survival. Invasive flap perfusion monitoring with direct blood flow feedback through the Cook–Swartz Doppler probe could enable earlier detection o...

Descripción completa

Detalles Bibliográficos
Autores principales: Paprottka, Felix J., Klimas, Dalius, Krezdorn, Nicco, Schlarb, Dominik, Trevatt, Alexander E. J., Hebebrand, Detlev
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Thieme Medical Publishers 2020
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7054061/
https://www.ncbi.nlm.nih.gov/pubmed/32133414
http://dx.doi.org/10.1055/s-0040-1702922
_version_ 1783503130797801472
author Paprottka, Felix J.
Klimas, Dalius
Krezdorn, Nicco
Schlarb, Dominik
Trevatt, Alexander E. J.
Hebebrand, Detlev
author_facet Paprottka, Felix J.
Klimas, Dalius
Krezdorn, Nicco
Schlarb, Dominik
Trevatt, Alexander E. J.
Hebebrand, Detlev
author_sort Paprottka, Felix J.
collection PubMed
description Introduction  The main postoperative complication of free flaps is perfusion compromise. Urgent intervention is critical to increase the chances of flap survival. Invasive flap perfusion monitoring with direct blood flow feedback through the Cook–Swartz Doppler probe could enable earlier detection of perfusion complications. Materials and Methods  Between 2012 and 2016, 35 patients underwent breast reconstruction or defect coverage after trauma with a deep inferior epigastric perforator, anterolateral thigh, transverse musculocutaneous gracilis, gracilis, or latissimus dorsi flap in our department. All flaps were monitored with a Cook–Swartz probe for 10 days postoperatively. The 20 MHz probe was placed around the arterial–venous anastomosis. A flap monitoring protocol was established for standardized surveillance of postoperative perfusion. In the event of probe signal loss, immediate surgical revision was initiated. Results  Signal loss was detected in 8 of the 35 cases. On return to the operating room, six were found to be true positives (relevant disruption of flap perfusion) and two were false positives (due to Doppler probe displacement). There were also two false negatives, resulting in a slowly progressive partial flap loss. Flap perfusion was restored in three of the six cases (50%) identified by the probe. Following surgical intervention, three of the six cases had persistent problems with perfusion, resulting in two total flap losses and one partial flap necrosis leading to an overall 5.7% total flap loss. Conclusion  Postoperative flap perfusion surveillance is a complex matter. Surgical experience is often helpful but not always reliable. The costs, false-positive, and false-negative rates associated with invasive perfusion monitoring with Cook–Swartz probe make it most appropriate for buried flaps. Level of Evidence  This is an original work.
format Online
Article
Text
id pubmed-7054061
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Thieme Medical Publishers
record_format MEDLINE/PubMed
spelling pubmed-70540612020-03-04 Cook–Swartz Doppler Probe Surveillance for Free Flaps—Defining Pros and Cons Paprottka, Felix J. Klimas, Dalius Krezdorn, Nicco Schlarb, Dominik Trevatt, Alexander E. J. Hebebrand, Detlev Surg J (N Y) Introduction  The main postoperative complication of free flaps is perfusion compromise. Urgent intervention is critical to increase the chances of flap survival. Invasive flap perfusion monitoring with direct blood flow feedback through the Cook–Swartz Doppler probe could enable earlier detection of perfusion complications. Materials and Methods  Between 2012 and 2016, 35 patients underwent breast reconstruction or defect coverage after trauma with a deep inferior epigastric perforator, anterolateral thigh, transverse musculocutaneous gracilis, gracilis, or latissimus dorsi flap in our department. All flaps were monitored with a Cook–Swartz probe for 10 days postoperatively. The 20 MHz probe was placed around the arterial–venous anastomosis. A flap monitoring protocol was established for standardized surveillance of postoperative perfusion. In the event of probe signal loss, immediate surgical revision was initiated. Results  Signal loss was detected in 8 of the 35 cases. On return to the operating room, six were found to be true positives (relevant disruption of flap perfusion) and two were false positives (due to Doppler probe displacement). There were also two false negatives, resulting in a slowly progressive partial flap loss. Flap perfusion was restored in three of the six cases (50%) identified by the probe. Following surgical intervention, three of the six cases had persistent problems with perfusion, resulting in two total flap losses and one partial flap necrosis leading to an overall 5.7% total flap loss. Conclusion  Postoperative flap perfusion surveillance is a complex matter. Surgical experience is often helpful but not always reliable. The costs, false-positive, and false-negative rates associated with invasive perfusion monitoring with Cook–Swartz probe make it most appropriate for buried flaps. Level of Evidence  This is an original work. Thieme Medical Publishers 2020-03-03 /pmc/articles/PMC7054061/ /pubmed/32133414 http://dx.doi.org/10.1055/s-0040-1702922 Text en https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Paprottka, Felix J.
Klimas, Dalius
Krezdorn, Nicco
Schlarb, Dominik
Trevatt, Alexander E. J.
Hebebrand, Detlev
Cook–Swartz Doppler Probe Surveillance for Free Flaps—Defining Pros and Cons
title Cook–Swartz Doppler Probe Surveillance for Free Flaps—Defining Pros and Cons
title_full Cook–Swartz Doppler Probe Surveillance for Free Flaps—Defining Pros and Cons
title_fullStr Cook–Swartz Doppler Probe Surveillance for Free Flaps—Defining Pros and Cons
title_full_unstemmed Cook–Swartz Doppler Probe Surveillance for Free Flaps—Defining Pros and Cons
title_short Cook–Swartz Doppler Probe Surveillance for Free Flaps—Defining Pros and Cons
title_sort cook–swartz doppler probe surveillance for free flaps—defining pros and cons
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7054061/
https://www.ncbi.nlm.nih.gov/pubmed/32133414
http://dx.doi.org/10.1055/s-0040-1702922
work_keys_str_mv AT paprottkafelixj cookswartzdopplerprobesurveillanceforfreeflapsdefiningprosandcons
AT klimasdalius cookswartzdopplerprobesurveillanceforfreeflapsdefiningprosandcons
AT krezdornnicco cookswartzdopplerprobesurveillanceforfreeflapsdefiningprosandcons
AT schlarbdominik cookswartzdopplerprobesurveillanceforfreeflapsdefiningprosandcons
AT trevattalexanderej cookswartzdopplerprobesurveillanceforfreeflapsdefiningprosandcons
AT hebebranddetlev cookswartzdopplerprobesurveillanceforfreeflapsdefiningprosandcons