Cargando…

Optical quality after posterior chamber Phakic implantation of an intraocular Lens with a central hole (V4c implantable Collamer Lens) under different lighting conditions

BACKGROUND: The current study compared optical quality before and after implantation of a posterior chamber phakic intraocular lens with a central hole [V4c implantable collamer lens (ICL)] under bright and dark lighting conditions by means of the Optical Quality Analysis System™ (OQAS; Visiometrics...

Descripción completa

Detalles Bibliográficos
Autores principales: He, Tianrui, Zhu, Yi, Zhou, Jibo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7055093/
https://www.ncbi.nlm.nih.gov/pubmed/32131800
http://dx.doi.org/10.1186/s12886-020-01340-0
_version_ 1783503307039309824
author He, Tianrui
Zhu, Yi
Zhou, Jibo
author_facet He, Tianrui
Zhu, Yi
Zhou, Jibo
author_sort He, Tianrui
collection PubMed
description BACKGROUND: The current study compared optical quality before and after implantation of a posterior chamber phakic intraocular lens with a central hole [V4c implantable collamer lens (ICL)] under bright and dark lighting conditions by means of the Optical Quality Analysis System™ (OQAS; Visiometrics, Terrassa, Spain). METHODS: This prospective study involved 91 eyes of 46 consecutive high myopia patients (15 males and 31 females, average spherical equivalent − 10.50 ± 0.33D) undergoing implantation of a V4c ICL. The modulation transfer function (MTF) cutoff frequency, Strehl ratio, objective scattering index (OSI), and predicted visual acuities (PVAs; 100, 20, and 9%), under different lighting conditions, were measured before and 1 week, 1 month, and 3 months after surgery. RESULTS: All optical parameters showed significant improvements, at all time points, under dark condition after surgery. We observed no significant changes in PVA 9% at 1 week (mean value 0.539, P = 0.12) or 1 month after surgery (mean value 0.573, P = 0.08) under bright condition; but all other postoperative parameters improved significantly. Comparing the two lighting conditions, the OSI decreased more under dark conditions at 1 week (P = 0.02), 1 month (P = 0.004), and 3 months (P = 0.002), but there was no significant difference in any other parameter. In addition, patients were divided into super high myopia (group S, spherical equivalent greater than − 10 D) and high myopia (group H, spherical equivalent from − 6 D to − 10 D), the group S improved significantly more than group H in all parameters, under both bright and dark conditions. CONCLUSIONS: V4c ICL implantation improved optical quality under both bright and dark lighting conditions, and had a better ability to reduce the extent of scattering in the dark. Furthermore, group S achieved greater improvement in visual quality, which should be considered by physicians before surgery.
format Online
Article
Text
id pubmed-7055093
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-70550932020-03-10 Optical quality after posterior chamber Phakic implantation of an intraocular Lens with a central hole (V4c implantable Collamer Lens) under different lighting conditions He, Tianrui Zhu, Yi Zhou, Jibo BMC Ophthalmol Research Article BACKGROUND: The current study compared optical quality before and after implantation of a posterior chamber phakic intraocular lens with a central hole [V4c implantable collamer lens (ICL)] under bright and dark lighting conditions by means of the Optical Quality Analysis System™ (OQAS; Visiometrics, Terrassa, Spain). METHODS: This prospective study involved 91 eyes of 46 consecutive high myopia patients (15 males and 31 females, average spherical equivalent − 10.50 ± 0.33D) undergoing implantation of a V4c ICL. The modulation transfer function (MTF) cutoff frequency, Strehl ratio, objective scattering index (OSI), and predicted visual acuities (PVAs; 100, 20, and 9%), under different lighting conditions, were measured before and 1 week, 1 month, and 3 months after surgery. RESULTS: All optical parameters showed significant improvements, at all time points, under dark condition after surgery. We observed no significant changes in PVA 9% at 1 week (mean value 0.539, P = 0.12) or 1 month after surgery (mean value 0.573, P = 0.08) under bright condition; but all other postoperative parameters improved significantly. Comparing the two lighting conditions, the OSI decreased more under dark conditions at 1 week (P = 0.02), 1 month (P = 0.004), and 3 months (P = 0.002), but there was no significant difference in any other parameter. In addition, patients were divided into super high myopia (group S, spherical equivalent greater than − 10 D) and high myopia (group H, spherical equivalent from − 6 D to − 10 D), the group S improved significantly more than group H in all parameters, under both bright and dark conditions. CONCLUSIONS: V4c ICL implantation improved optical quality under both bright and dark lighting conditions, and had a better ability to reduce the extent of scattering in the dark. Furthermore, group S achieved greater improvement in visual quality, which should be considered by physicians before surgery. BioMed Central 2020-03-04 /pmc/articles/PMC7055093/ /pubmed/32131800 http://dx.doi.org/10.1186/s12886-020-01340-0 Text en © The Author(s) 2020 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
He, Tianrui
Zhu, Yi
Zhou, Jibo
Optical quality after posterior chamber Phakic implantation of an intraocular Lens with a central hole (V4c implantable Collamer Lens) under different lighting conditions
title Optical quality after posterior chamber Phakic implantation of an intraocular Lens with a central hole (V4c implantable Collamer Lens) under different lighting conditions
title_full Optical quality after posterior chamber Phakic implantation of an intraocular Lens with a central hole (V4c implantable Collamer Lens) under different lighting conditions
title_fullStr Optical quality after posterior chamber Phakic implantation of an intraocular Lens with a central hole (V4c implantable Collamer Lens) under different lighting conditions
title_full_unstemmed Optical quality after posterior chamber Phakic implantation of an intraocular Lens with a central hole (V4c implantable Collamer Lens) under different lighting conditions
title_short Optical quality after posterior chamber Phakic implantation of an intraocular Lens with a central hole (V4c implantable Collamer Lens) under different lighting conditions
title_sort optical quality after posterior chamber phakic implantation of an intraocular lens with a central hole (v4c implantable collamer lens) under different lighting conditions
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7055093/
https://www.ncbi.nlm.nih.gov/pubmed/32131800
http://dx.doi.org/10.1186/s12886-020-01340-0
work_keys_str_mv AT hetianrui opticalqualityafterposteriorchamberphakicimplantationofanintraocularlenswithacentralholev4cimplantablecollamerlensunderdifferentlightingconditions
AT zhuyi opticalqualityafterposteriorchamberphakicimplantationofanintraocularlenswithacentralholev4cimplantablecollamerlensunderdifferentlightingconditions
AT zhoujibo opticalqualityafterposteriorchamberphakicimplantationofanintraocularlenswithacentralholev4cimplantablecollamerlensunderdifferentlightingconditions