Fiber orientation in a whole mouse heart reconstructed by laboratory phase-contrast micro-CT

Purpose: We present a phase-contrast x-ray tomography study of wild type C57BL/6 mouse hearts as a nondestructive approach to the microanatomy on the scale of the entire excised organ. Based on the partial coherence at a home-built phase-contrast [Formula: see text] setup installed at a liquid metal...

Descripción completa

Detalles Bibliográficos
Autores principales: Reichardt, Marius, Töpperwien, Mareike, Khan, Amara, Alves, Frauke, Salditt, Tim
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Society of Photo-Optical Instrumentation Engineers 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7055497/
https://www.ncbi.nlm.nih.gov/pubmed/32206684
http://dx.doi.org/10.1117/1.JMI.7.2.023501
_version_ 1783503374987034624
author Reichardt, Marius
Töpperwien, Mareike
Khan, Amara
Alves, Frauke
Salditt, Tim
author_facet Reichardt, Marius
Töpperwien, Mareike
Khan, Amara
Alves, Frauke
Salditt, Tim
author_sort Reichardt, Marius
collection PubMed
description Purpose: We present a phase-contrast x-ray tomography study of wild type C57BL/6 mouse hearts as a nondestructive approach to the microanatomy on the scale of the entire excised organ. Based on the partial coherence at a home-built phase-contrast [Formula: see text] setup installed at a liquid metal jet source, we exploit phase retrieval and hence achieve superior image quality for heart tissue, almost comparable to previous synchrotron data on the whole organ scale. Approach: In our work, different embedding methods and heavy metal-based stains have been explored. From the tomographic reconstructions, quantitative structural parameters describing the three-dimensional (3-D) architecture have been derived by two different fiber tracking algorithms. The first algorithm is based on the local gradient of the reconstructed electron density. By performing a principal component analysis on the local structure-tensor of small subvolumes, the dominant direction inside the volume can be determined. In addition to this approach, which is already well established for heart tissue, we have implemented and tested an algorithm that is based on a local 3-D Fourier transform. Results: We showed that the choice of sample preparation influences the 3-D structure of the tissue, not only in terms of contrast but also with respect to the structural preservation. A heart prepared with the evaporation-of-solvent method was used to compare both algorithms. The results of structural orientation were very similar for both approaches. In addition to the determination of the fiber orientation, the degree of filament alignment and local thickness of single muscle fiber bundles were obtained using the Fourier-based approach. Conclusions: Phase-contrast x-ray tomography allows for investigating the structure of heart tissue with an isotropic resolution below [Formula: see text]. The fact that this is possible with compact laboratory instrumentation opens up new opportunities for screening samples and optimizing sample preparation, also prior to synchrotron beamtimes. Further, results from the structural analysis can help in understanding cardiovascular diseases or can be used to improve computational models of the heart.
format Online
Article
Text
id pubmed-7055497
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Society of Photo-Optical Instrumentation Engineers
record_format MEDLINE/PubMed
spelling pubmed-70554972021-03-04 Fiber orientation in a whole mouse heart reconstructed by laboratory phase-contrast micro-CT Reichardt, Marius Töpperwien, Mareike Khan, Amara Alves, Frauke Salditt, Tim J Med Imaging (Bellingham) Physics of Medical Imaging Purpose: We present a phase-contrast x-ray tomography study of wild type C57BL/6 mouse hearts as a nondestructive approach to the microanatomy on the scale of the entire excised organ. Based on the partial coherence at a home-built phase-contrast [Formula: see text] setup installed at a liquid metal jet source, we exploit phase retrieval and hence achieve superior image quality for heart tissue, almost comparable to previous synchrotron data on the whole organ scale. Approach: In our work, different embedding methods and heavy metal-based stains have been explored. From the tomographic reconstructions, quantitative structural parameters describing the three-dimensional (3-D) architecture have been derived by two different fiber tracking algorithms. The first algorithm is based on the local gradient of the reconstructed electron density. By performing a principal component analysis on the local structure-tensor of small subvolumes, the dominant direction inside the volume can be determined. In addition to this approach, which is already well established for heart tissue, we have implemented and tested an algorithm that is based on a local 3-D Fourier transform. Results: We showed that the choice of sample preparation influences the 3-D structure of the tissue, not only in terms of contrast but also with respect to the structural preservation. A heart prepared with the evaporation-of-solvent method was used to compare both algorithms. The results of structural orientation were very similar for both approaches. In addition to the determination of the fiber orientation, the degree of filament alignment and local thickness of single muscle fiber bundles were obtained using the Fourier-based approach. Conclusions: Phase-contrast x-ray tomography allows for investigating the structure of heart tissue with an isotropic resolution below [Formula: see text]. The fact that this is possible with compact laboratory instrumentation opens up new opportunities for screening samples and optimizing sample preparation, also prior to synchrotron beamtimes. Further, results from the structural analysis can help in understanding cardiovascular diseases or can be used to improve computational models of the heart. Society of Photo-Optical Instrumentation Engineers 2020-03-04 2020-03 /pmc/articles/PMC7055497/ /pubmed/32206684 http://dx.doi.org/10.1117/1.JMI.7.2.023501 Text en © 2020 The Authors https://creativecommons.org/licenses/by/4.0/ Published by SPIE under a Creative Commons Attribution 4.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
spellingShingle Physics of Medical Imaging
Reichardt, Marius
Töpperwien, Mareike
Khan, Amara
Alves, Frauke
Salditt, Tim
Fiber orientation in a whole mouse heart reconstructed by laboratory phase-contrast micro-CT
title Fiber orientation in a whole mouse heart reconstructed by laboratory phase-contrast micro-CT
title_full Fiber orientation in a whole mouse heart reconstructed by laboratory phase-contrast micro-CT
title_fullStr Fiber orientation in a whole mouse heart reconstructed by laboratory phase-contrast micro-CT
title_full_unstemmed Fiber orientation in a whole mouse heart reconstructed by laboratory phase-contrast micro-CT
title_short Fiber orientation in a whole mouse heart reconstructed by laboratory phase-contrast micro-CT
title_sort fiber orientation in a whole mouse heart reconstructed by laboratory phase-contrast micro-ct
topic Physics of Medical Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7055497/
https://www.ncbi.nlm.nih.gov/pubmed/32206684
http://dx.doi.org/10.1117/1.JMI.7.2.023501
work_keys_str_mv AT reichardtmarius fiberorientationinawholemouseheartreconstructedbylaboratoryphasecontrastmicroct
AT topperwienmareike fiberorientationinawholemouseheartreconstructedbylaboratoryphasecontrastmicroct
AT khanamara fiberorientationinawholemouseheartreconstructedbylaboratoryphasecontrastmicroct
AT alvesfrauke fiberorientationinawholemouseheartreconstructedbylaboratoryphasecontrastmicroct
AT salditttim fiberorientationinawholemouseheartreconstructedbylaboratoryphasecontrastmicroct