Cervical Characterization with Tactile-Ultrasound Probe

BACKGROUND: Premature cervical softening and shortening may be considered an early mechanical failure that predisposes to preterm birth. Preliminary clinical studies demonstrate that cervical elastography may be able to quantify this phenomenon and predict spontaneous preterm delivery. OBJECTIVE: To...

Descripción completa

Detalles Bibliográficos
Autores principales: Egorov, Vladimir, Rosen, Todd, van Raalte, Heather, Kurtenoks, Viktors
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7055710/
https://www.ncbi.nlm.nih.gov/pubmed/32133244
http://dx.doi.org/10.4236/ojog.2020.101008
_version_ 1783503405377912832
author Egorov, Vladimir
Rosen, Todd
van Raalte, Heather
Kurtenoks, Viktors
author_facet Egorov, Vladimir
Rosen, Todd
van Raalte, Heather
Kurtenoks, Viktors
author_sort Egorov, Vladimir
collection PubMed
description BACKGROUND: Premature cervical softening and shortening may be considered an early mechanical failure that predisposes to preterm birth. Preliminary clinical studies demonstrate that cervical elastography may be able to quantify this phenomenon and predict spontaneous preterm delivery. OBJECTIVE: To explore a new approach for cervix elasticity and length measurements with tactile-ultrasound probe. METHODS: Cervix probe has tactile array and ultrasound transducer designed to apply controllable load to cervix and acquire stress-strain data for calculation of cervical elasticity (Young’s modulus) and cervical length for four cervix sectors. Average values, standard deviations, intraclass correlation coefficients and the 95% limits of agreement (Bland-Altman plots) were estimated. RESULTS: Ten non-pregnant and ten pregnant women were examined with the probe. The study with non-pregnant women demonstrated a reliable acquisition of the tactile signals. The ultrasound signals had a prolonged appearance; identification of the internal os of the cervix in these signals was not reliable. The study with pregnant women with the gestational age of 25.4 ± 2.3 weeks demonstrated reliable data acquisition with real-time visualization of the ultrasound signals. Average values for cervical elasticity and standard deviations of 19.7 ± 15.4 kPa and length of 30.7 ± 6.6 mm were calculated based on two measurements per 4 sectors. Measurement repeatability calculated as intraclass correlation coefficients between two measurements at the same cervix sector on pregnant women was found to be 0.97 for cervical elasticity and 0.93 for the cervical length. The 95% limits of agreement of 1) cervical elasticity were from −22.4% to +14.9%, and 2) cervical length from −13.3% to +16.5%. CONCLUSIONS: This study demonstrated clinically acceptable measurement performance and reproducibility. The availability of stress-strain data allowed the computation of cervical elasticity and length. This approach has the potential to provide cervical markers to predict spontaneous preterm delivery.
format Online
Article
Text
id pubmed-7055710
institution National Center for Biotechnology Information
language English
publishDate 2020
record_format MEDLINE/PubMed
spelling pubmed-70557102020-03-04 Cervical Characterization with Tactile-Ultrasound Probe Egorov, Vladimir Rosen, Todd van Raalte, Heather Kurtenoks, Viktors Open J Obstet Gynecol Article BACKGROUND: Premature cervical softening and shortening may be considered an early mechanical failure that predisposes to preterm birth. Preliminary clinical studies demonstrate that cervical elastography may be able to quantify this phenomenon and predict spontaneous preterm delivery. OBJECTIVE: To explore a new approach for cervix elasticity and length measurements with tactile-ultrasound probe. METHODS: Cervix probe has tactile array and ultrasound transducer designed to apply controllable load to cervix and acquire stress-strain data for calculation of cervical elasticity (Young’s modulus) and cervical length for four cervix sectors. Average values, standard deviations, intraclass correlation coefficients and the 95% limits of agreement (Bland-Altman plots) were estimated. RESULTS: Ten non-pregnant and ten pregnant women were examined with the probe. The study with non-pregnant women demonstrated a reliable acquisition of the tactile signals. The ultrasound signals had a prolonged appearance; identification of the internal os of the cervix in these signals was not reliable. The study with pregnant women with the gestational age of 25.4 ± 2.3 weeks demonstrated reliable data acquisition with real-time visualization of the ultrasound signals. Average values for cervical elasticity and standard deviations of 19.7 ± 15.4 kPa and length of 30.7 ± 6.6 mm were calculated based on two measurements per 4 sectors. Measurement repeatability calculated as intraclass correlation coefficients between two measurements at the same cervix sector on pregnant women was found to be 0.97 for cervical elasticity and 0.93 for the cervical length. The 95% limits of agreement of 1) cervical elasticity were from −22.4% to +14.9%, and 2) cervical length from −13.3% to +16.5%. CONCLUSIONS: This study demonstrated clinically acceptable measurement performance and reproducibility. The availability of stress-strain data allowed the computation of cervical elasticity and length. This approach has the potential to provide cervical markers to predict spontaneous preterm delivery. 2020-01-08 2020-01 /pmc/articles/PMC7055710/ /pubmed/32133244 http://dx.doi.org/10.4236/ojog.2020.101008 Text en This work is licensed under the Creative Commons Attribution International License (CC BY 4.0). http://creativecommons.org/licenses/by/4.0/
spellingShingle Article
Egorov, Vladimir
Rosen, Todd
van Raalte, Heather
Kurtenoks, Viktors
Cervical Characterization with Tactile-Ultrasound Probe
title Cervical Characterization with Tactile-Ultrasound Probe
title_full Cervical Characterization with Tactile-Ultrasound Probe
title_fullStr Cervical Characterization with Tactile-Ultrasound Probe
title_full_unstemmed Cervical Characterization with Tactile-Ultrasound Probe
title_short Cervical Characterization with Tactile-Ultrasound Probe
title_sort cervical characterization with tactile-ultrasound probe
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7055710/
https://www.ncbi.nlm.nih.gov/pubmed/32133244
http://dx.doi.org/10.4236/ojog.2020.101008
work_keys_str_mv AT egorovvladimir cervicalcharacterizationwithtactileultrasoundprobe
AT rosentodd cervicalcharacterizationwithtactileultrasoundprobe
AT vanraalteheather cervicalcharacterizationwithtactileultrasoundprobe
AT kurtenoksviktors cervicalcharacterizationwithtactileultrasoundprobe