Analytical Low-Dose CBCT Reconstruction Using Non-local Total Variation Regularization for Image Guided Radiation Therapy

Purpose: Conventional iterative low-dose CBCT reconstruction techniques are slow and tend to over-smooth edges through uniform weighting of the image penalty gradient. In this study, we present a non-iterative analytical low-dose CBCT reconstruction technique by restoring the noisy low-dose CBCT pro...

Descripción completa

Detalles Bibliográficos
Autores principales: Sohn, James J., Kim, Changsoo, Kim, Dong Hyun, Lee, Seu-Ran, Zhou, Jun, Yang, Xiaofeng, Liu, Tian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7056884/
https://www.ncbi.nlm.nih.gov/pubmed/32175282
http://dx.doi.org/10.3389/fonc.2020.00242
_version_ 1783503552456425472
author Sohn, James J.
Kim, Changsoo
Kim, Dong Hyun
Lee, Seu-Ran
Zhou, Jun
Yang, Xiaofeng
Liu, Tian
author_facet Sohn, James J.
Kim, Changsoo
Kim, Dong Hyun
Lee, Seu-Ran
Zhou, Jun
Yang, Xiaofeng
Liu, Tian
author_sort Sohn, James J.
collection PubMed
description Purpose: Conventional iterative low-dose CBCT reconstruction techniques are slow and tend to over-smooth edges through uniform weighting of the image penalty gradient. In this study, we present a non-iterative analytical low-dose CBCT reconstruction technique by restoring the noisy low-dose CBCT projection with the non-local total variation (NLTV) method. Methods: We modeled the low-dose CBCT reconstruction as recovering high quality, high-dose CBCT x-ray projections (100 kVp, 1.6 mAs) from low-dose, noisy CBCT x-ray projections (100 kVp, 0.1 mAs). The restoration of CBCT projections was performed using the NLTV regularization method. In NLTV, the x-ray image is optimized by minimizing an energy function that penalizes gray-level difference between pair of pixels between noisy x-ray projection and denoising x-ray projection. After the noisy projection is restored by NLTV regularization, the standard FDK method was applied to generate the final reconstruction output. Results: Significant noise reduction was achieved comparing to original, noisy inputs while maintaining the image quality comparable to the high-dose CBCT projections. The experimental validations show the proposed NLTV algorithm can robustly restore the noise level of x-ray projection images while significantly improving the overall image quality. The improvement in normalized mean square error (NMSE) and peak signal-to-noise ratio (PSNR) measured from the non-local total variation-gradient projection (NLTV-GPSR) algorithm is noticeable compared to that of uncorrected low-dose CBCT images. Moreover, the difference of CNRs from the gains from the proposed algorithm is noticeable and comparable to high-dose CBCT. Conclusion: The proposed method successfully restores noise degraded, low-dose CBCT projections to high-dose projection quality. Such an outcome is a considerable improvement to the reconstruction result compared to the FDK-based method. In addition, a significant reduction in reconstruction time makes the proposed algorithm more attractive. This demonstrates the potential use of the proposed algorithm for clinical practice in radiotherapy.
format Online
Article
Text
id pubmed-7056884
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-70568842020-03-13 Analytical Low-Dose CBCT Reconstruction Using Non-local Total Variation Regularization for Image Guided Radiation Therapy Sohn, James J. Kim, Changsoo Kim, Dong Hyun Lee, Seu-Ran Zhou, Jun Yang, Xiaofeng Liu, Tian Front Oncol Oncology Purpose: Conventional iterative low-dose CBCT reconstruction techniques are slow and tend to over-smooth edges through uniform weighting of the image penalty gradient. In this study, we present a non-iterative analytical low-dose CBCT reconstruction technique by restoring the noisy low-dose CBCT projection with the non-local total variation (NLTV) method. Methods: We modeled the low-dose CBCT reconstruction as recovering high quality, high-dose CBCT x-ray projections (100 kVp, 1.6 mAs) from low-dose, noisy CBCT x-ray projections (100 kVp, 0.1 mAs). The restoration of CBCT projections was performed using the NLTV regularization method. In NLTV, the x-ray image is optimized by minimizing an energy function that penalizes gray-level difference between pair of pixels between noisy x-ray projection and denoising x-ray projection. After the noisy projection is restored by NLTV regularization, the standard FDK method was applied to generate the final reconstruction output. Results: Significant noise reduction was achieved comparing to original, noisy inputs while maintaining the image quality comparable to the high-dose CBCT projections. The experimental validations show the proposed NLTV algorithm can robustly restore the noise level of x-ray projection images while significantly improving the overall image quality. The improvement in normalized mean square error (NMSE) and peak signal-to-noise ratio (PSNR) measured from the non-local total variation-gradient projection (NLTV-GPSR) algorithm is noticeable compared to that of uncorrected low-dose CBCT images. Moreover, the difference of CNRs from the gains from the proposed algorithm is noticeable and comparable to high-dose CBCT. Conclusion: The proposed method successfully restores noise degraded, low-dose CBCT projections to high-dose projection quality. Such an outcome is a considerable improvement to the reconstruction result compared to the FDK-based method. In addition, a significant reduction in reconstruction time makes the proposed algorithm more attractive. This demonstrates the potential use of the proposed algorithm for clinical practice in radiotherapy. Frontiers Media S.A. 2020-02-27 /pmc/articles/PMC7056884/ /pubmed/32175282 http://dx.doi.org/10.3389/fonc.2020.00242 Text en Copyright © 2020 Sohn, Kim, Kim, Lee, Zhou, Yang and Liu. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Oncology
Sohn, James J.
Kim, Changsoo
Kim, Dong Hyun
Lee, Seu-Ran
Zhou, Jun
Yang, Xiaofeng
Liu, Tian
Analytical Low-Dose CBCT Reconstruction Using Non-local Total Variation Regularization for Image Guided Radiation Therapy
title Analytical Low-Dose CBCT Reconstruction Using Non-local Total Variation Regularization for Image Guided Radiation Therapy
title_full Analytical Low-Dose CBCT Reconstruction Using Non-local Total Variation Regularization for Image Guided Radiation Therapy
title_fullStr Analytical Low-Dose CBCT Reconstruction Using Non-local Total Variation Regularization for Image Guided Radiation Therapy
title_full_unstemmed Analytical Low-Dose CBCT Reconstruction Using Non-local Total Variation Regularization for Image Guided Radiation Therapy
title_short Analytical Low-Dose CBCT Reconstruction Using Non-local Total Variation Regularization for Image Guided Radiation Therapy
title_sort analytical low-dose cbct reconstruction using non-local total variation regularization for image guided radiation therapy
topic Oncology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7056884/
https://www.ncbi.nlm.nih.gov/pubmed/32175282
http://dx.doi.org/10.3389/fonc.2020.00242
work_keys_str_mv AT sohnjamesj analyticallowdosecbctreconstructionusingnonlocaltotalvariationregularizationforimageguidedradiationtherapy
AT kimchangsoo analyticallowdosecbctreconstructionusingnonlocaltotalvariationregularizationforimageguidedradiationtherapy
AT kimdonghyun analyticallowdosecbctreconstructionusingnonlocaltotalvariationregularizationforimageguidedradiationtherapy
AT leeseuran analyticallowdosecbctreconstructionusingnonlocaltotalvariationregularizationforimageguidedradiationtherapy
AT zhoujun analyticallowdosecbctreconstructionusingnonlocaltotalvariationregularizationforimageguidedradiationtherapy
AT yangxiaofeng analyticallowdosecbctreconstructionusingnonlocaltotalvariationregularizationforimageguidedradiationtherapy
AT liutian analyticallowdosecbctreconstructionusingnonlocaltotalvariationregularizationforimageguidedradiationtherapy