Cargando…
Freehand Insertion of External Ventricular Drainage Catheter: Evaluation of Accuracy in a Single Center
INTRODUCTION: External ventricular drain (EVD) placement is the gold standard for managing acute hydrocephalus. Freehand EVD, using surface anatomical landmarks, is performed for ventricular cannulation due to its simplicity and efficiency. This study evaluates accuracy and reason(s) for misplacemen...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7057862/ https://www.ncbi.nlm.nih.gov/pubmed/32181172 http://dx.doi.org/10.4103/ajns.AJNS_292_19 |
_version_ | 1783503750191644672 |
---|---|
author | Lee, Keng Siang Zhang, John Jiong Yang Bolem, Nagarjun Leong, May Lian Goh, Chun Peng Hassan, Rashidul Salek, Al Amin Maa Sein Lwin, Asher Paul Tan Teo, Kejia Chou, Ning Nga, Vincent Yeo, Tseng Tsai |
author_facet | Lee, Keng Siang Zhang, John Jiong Yang Bolem, Nagarjun Leong, May Lian Goh, Chun Peng Hassan, Rashidul Salek, Al Amin Maa Sein Lwin, Asher Paul Tan Teo, Kejia Chou, Ning Nga, Vincent Yeo, Tseng Tsai |
author_sort | Lee, Keng Siang |
collection | PubMed |
description | INTRODUCTION: External ventricular drain (EVD) placement is the gold standard for managing acute hydrocephalus. Freehand EVD, using surface anatomical landmarks, is performed for ventricular cannulation due to its simplicity and efficiency. This study evaluates accuracy and reason(s) for misplacements as few studies have analyzed the accuracy of freehand EVD insertion. PATIENTS AND METHODS: Preoperative and postoperative computed tomography scans of patients who underwent EVD insertion in 2014 were retrospectively reviewed. Diagnosis, Evans ratio, midline shift, position of burr hole, length of the catheter, and procedural complications were tabulated. The procedures were classified as satisfactory (catheter tip in the frontal horn ipsilateral lateral ventricle) and unsatisfactory. Unsatisfactory cases were further analyzed in relation to position of burr hole from midline and length of the catheter. RESULTS: Seventy-seven EVD placements in seventy patients were evaluated. The mean age of the patients was 57.5 years. About 83.1% were satisfactory placements and 11.7% were unsatisfactory in the contralateral ventricle, corpus callosum, and interhemispheric fissure. Nearly 5.2% were in extraventricular locations. Almost 2.6% EVD placements were complicated by hemorrhage and 1 catheter was reinserted. Suboptimal placements were significantly associated with longer intracranial catheter length. The mean length was 66.54 ± 10.1 mm in unsatisfactory placements compared to 58.32 ± 4.85 mm in satisfactory placements. Between the two groups, no significant difference was observed in Evans ratio, midline shift, surgeon's experience, distance of burr hole from midline, and coronal suture. CONCLUSION: Freehand EVD insertion is safe and accurate. In small number of cases, unsatisfactory placement is related to longer catheter length. |
format | Online Article Text |
id | pubmed-7057862 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-70578622020-03-16 Freehand Insertion of External Ventricular Drainage Catheter: Evaluation of Accuracy in a Single Center Lee, Keng Siang Zhang, John Jiong Yang Bolem, Nagarjun Leong, May Lian Goh, Chun Peng Hassan, Rashidul Salek, Al Amin Maa Sein Lwin, Asher Paul Tan Teo, Kejia Chou, Ning Nga, Vincent Yeo, Tseng Tsai Asian J Neurosurg Original Article INTRODUCTION: External ventricular drain (EVD) placement is the gold standard for managing acute hydrocephalus. Freehand EVD, using surface anatomical landmarks, is performed for ventricular cannulation due to its simplicity and efficiency. This study evaluates accuracy and reason(s) for misplacements as few studies have analyzed the accuracy of freehand EVD insertion. PATIENTS AND METHODS: Preoperative and postoperative computed tomography scans of patients who underwent EVD insertion in 2014 were retrospectively reviewed. Diagnosis, Evans ratio, midline shift, position of burr hole, length of the catheter, and procedural complications were tabulated. The procedures were classified as satisfactory (catheter tip in the frontal horn ipsilateral lateral ventricle) and unsatisfactory. Unsatisfactory cases were further analyzed in relation to position of burr hole from midline and length of the catheter. RESULTS: Seventy-seven EVD placements in seventy patients were evaluated. The mean age of the patients was 57.5 years. About 83.1% were satisfactory placements and 11.7% were unsatisfactory in the contralateral ventricle, corpus callosum, and interhemispheric fissure. Nearly 5.2% were in extraventricular locations. Almost 2.6% EVD placements were complicated by hemorrhage and 1 catheter was reinserted. Suboptimal placements were significantly associated with longer intracranial catheter length. The mean length was 66.54 ± 10.1 mm in unsatisfactory placements compared to 58.32 ± 4.85 mm in satisfactory placements. Between the two groups, no significant difference was observed in Evans ratio, midline shift, surgeon's experience, distance of burr hole from midline, and coronal suture. CONCLUSION: Freehand EVD insertion is safe and accurate. In small number of cases, unsatisfactory placement is related to longer catheter length. Wolters Kluwer - Medknow 2020-02-25 /pmc/articles/PMC7057862/ /pubmed/32181172 http://dx.doi.org/10.4103/ajns.AJNS_292_19 Text en Copyright: © 2020 Asian Journal of Neurosurgery http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Lee, Keng Siang Zhang, John Jiong Yang Bolem, Nagarjun Leong, May Lian Goh, Chun Peng Hassan, Rashidul Salek, Al Amin Maa Sein Lwin, Asher Paul Tan Teo, Kejia Chou, Ning Nga, Vincent Yeo, Tseng Tsai Freehand Insertion of External Ventricular Drainage Catheter: Evaluation of Accuracy in a Single Center |
title | Freehand Insertion of External Ventricular Drainage Catheter: Evaluation of Accuracy in a Single Center |
title_full | Freehand Insertion of External Ventricular Drainage Catheter: Evaluation of Accuracy in a Single Center |
title_fullStr | Freehand Insertion of External Ventricular Drainage Catheter: Evaluation of Accuracy in a Single Center |
title_full_unstemmed | Freehand Insertion of External Ventricular Drainage Catheter: Evaluation of Accuracy in a Single Center |
title_short | Freehand Insertion of External Ventricular Drainage Catheter: Evaluation of Accuracy in a Single Center |
title_sort | freehand insertion of external ventricular drainage catheter: evaluation of accuracy in a single center |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7057862/ https://www.ncbi.nlm.nih.gov/pubmed/32181172 http://dx.doi.org/10.4103/ajns.AJNS_292_19 |
work_keys_str_mv | AT leekengsiang freehandinsertionofexternalventriculardrainagecatheterevaluationofaccuracyinasinglecenter AT zhangjohnjiongyang freehandinsertionofexternalventriculardrainagecatheterevaluationofaccuracyinasinglecenter AT bolemnagarjun freehandinsertionofexternalventriculardrainagecatheterevaluationofaccuracyinasinglecenter AT leongmaylian freehandinsertionofexternalventriculardrainagecatheterevaluationofaccuracyinasinglecenter AT gohchunpeng freehandinsertionofexternalventriculardrainagecatheterevaluationofaccuracyinasinglecenter AT hassanrashidul freehandinsertionofexternalventriculardrainagecatheterevaluationofaccuracyinasinglecenter AT salekalaminmaa freehandinsertionofexternalventriculardrainagecatheterevaluationofaccuracyinasinglecenter AT seinlwinasherpaultan freehandinsertionofexternalventriculardrainagecatheterevaluationofaccuracyinasinglecenter AT teokejia freehandinsertionofexternalventriculardrainagecatheterevaluationofaccuracyinasinglecenter AT chouning freehandinsertionofexternalventriculardrainagecatheterevaluationofaccuracyinasinglecenter AT ngavincent freehandinsertionofexternalventriculardrainagecatheterevaluationofaccuracyinasinglecenter AT yeotsengtsai freehandinsertionofexternalventriculardrainagecatheterevaluationofaccuracyinasinglecenter |