Cargando…

Freehand Insertion of External Ventricular Drainage Catheter: Evaluation of Accuracy in a Single Center

INTRODUCTION: External ventricular drain (EVD) placement is the gold standard for managing acute hydrocephalus. Freehand EVD, using surface anatomical landmarks, is performed for ventricular cannulation due to its simplicity and efficiency. This study evaluates accuracy and reason(s) for misplacemen...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Keng Siang, Zhang, John Jiong Yang, Bolem, Nagarjun, Leong, May Lian, Goh, Chun Peng, Hassan, Rashidul, Salek, Al Amin Maa, Sein Lwin, Asher Paul Tan, Teo, Kejia, Chou, Ning, Nga, Vincent, Yeo, Tseng Tsai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7057862/
https://www.ncbi.nlm.nih.gov/pubmed/32181172
http://dx.doi.org/10.4103/ajns.AJNS_292_19
_version_ 1783503750191644672
author Lee, Keng Siang
Zhang, John Jiong Yang
Bolem, Nagarjun
Leong, May Lian
Goh, Chun Peng
Hassan, Rashidul
Salek, Al Amin Maa
Sein Lwin, Asher Paul Tan
Teo, Kejia
Chou, Ning
Nga, Vincent
Yeo, Tseng Tsai
author_facet Lee, Keng Siang
Zhang, John Jiong Yang
Bolem, Nagarjun
Leong, May Lian
Goh, Chun Peng
Hassan, Rashidul
Salek, Al Amin Maa
Sein Lwin, Asher Paul Tan
Teo, Kejia
Chou, Ning
Nga, Vincent
Yeo, Tseng Tsai
author_sort Lee, Keng Siang
collection PubMed
description INTRODUCTION: External ventricular drain (EVD) placement is the gold standard for managing acute hydrocephalus. Freehand EVD, using surface anatomical landmarks, is performed for ventricular cannulation due to its simplicity and efficiency. This study evaluates accuracy and reason(s) for misplacements as few studies have analyzed the accuracy of freehand EVD insertion. PATIENTS AND METHODS: Preoperative and postoperative computed tomography scans of patients who underwent EVD insertion in 2014 were retrospectively reviewed. Diagnosis, Evans ratio, midline shift, position of burr hole, length of the catheter, and procedural complications were tabulated. The procedures were classified as satisfactory (catheter tip in the frontal horn ipsilateral lateral ventricle) and unsatisfactory. Unsatisfactory cases were further analyzed in relation to position of burr hole from midline and length of the catheter. RESULTS: Seventy-seven EVD placements in seventy patients were evaluated. The mean age of the patients was 57.5 years. About 83.1% were satisfactory placements and 11.7% were unsatisfactory in the contralateral ventricle, corpus callosum, and interhemispheric fissure. Nearly 5.2% were in extraventricular locations. Almost 2.6% EVD placements were complicated by hemorrhage and 1 catheter was reinserted. Suboptimal placements were significantly associated with longer intracranial catheter length. The mean length was 66.54 ± 10.1 mm in unsatisfactory placements compared to 58.32 ± 4.85 mm in satisfactory placements. Between the two groups, no significant difference was observed in Evans ratio, midline shift, surgeon's experience, distance of burr hole from midline, and coronal suture. CONCLUSION: Freehand EVD insertion is safe and accurate. In small number of cases, unsatisfactory placement is related to longer catheter length.
format Online
Article
Text
id pubmed-7057862
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-70578622020-03-16 Freehand Insertion of External Ventricular Drainage Catheter: Evaluation of Accuracy in a Single Center Lee, Keng Siang Zhang, John Jiong Yang Bolem, Nagarjun Leong, May Lian Goh, Chun Peng Hassan, Rashidul Salek, Al Amin Maa Sein Lwin, Asher Paul Tan Teo, Kejia Chou, Ning Nga, Vincent Yeo, Tseng Tsai Asian J Neurosurg Original Article INTRODUCTION: External ventricular drain (EVD) placement is the gold standard for managing acute hydrocephalus. Freehand EVD, using surface anatomical landmarks, is performed for ventricular cannulation due to its simplicity and efficiency. This study evaluates accuracy and reason(s) for misplacements as few studies have analyzed the accuracy of freehand EVD insertion. PATIENTS AND METHODS: Preoperative and postoperative computed tomography scans of patients who underwent EVD insertion in 2014 were retrospectively reviewed. Diagnosis, Evans ratio, midline shift, position of burr hole, length of the catheter, and procedural complications were tabulated. The procedures were classified as satisfactory (catheter tip in the frontal horn ipsilateral lateral ventricle) and unsatisfactory. Unsatisfactory cases were further analyzed in relation to position of burr hole from midline and length of the catheter. RESULTS: Seventy-seven EVD placements in seventy patients were evaluated. The mean age of the patients was 57.5 years. About 83.1% were satisfactory placements and 11.7% were unsatisfactory in the contralateral ventricle, corpus callosum, and interhemispheric fissure. Nearly 5.2% were in extraventricular locations. Almost 2.6% EVD placements were complicated by hemorrhage and 1 catheter was reinserted. Suboptimal placements were significantly associated with longer intracranial catheter length. The mean length was 66.54 ± 10.1 mm in unsatisfactory placements compared to 58.32 ± 4.85 mm in satisfactory placements. Between the two groups, no significant difference was observed in Evans ratio, midline shift, surgeon's experience, distance of burr hole from midline, and coronal suture. CONCLUSION: Freehand EVD insertion is safe and accurate. In small number of cases, unsatisfactory placement is related to longer catheter length. Wolters Kluwer - Medknow 2020-02-25 /pmc/articles/PMC7057862/ /pubmed/32181172 http://dx.doi.org/10.4103/ajns.AJNS_292_19 Text en Copyright: © 2020 Asian Journal of Neurosurgery http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Lee, Keng Siang
Zhang, John Jiong Yang
Bolem, Nagarjun
Leong, May Lian
Goh, Chun Peng
Hassan, Rashidul
Salek, Al Amin Maa
Sein Lwin, Asher Paul Tan
Teo, Kejia
Chou, Ning
Nga, Vincent
Yeo, Tseng Tsai
Freehand Insertion of External Ventricular Drainage Catheter: Evaluation of Accuracy in a Single Center
title Freehand Insertion of External Ventricular Drainage Catheter: Evaluation of Accuracy in a Single Center
title_full Freehand Insertion of External Ventricular Drainage Catheter: Evaluation of Accuracy in a Single Center
title_fullStr Freehand Insertion of External Ventricular Drainage Catheter: Evaluation of Accuracy in a Single Center
title_full_unstemmed Freehand Insertion of External Ventricular Drainage Catheter: Evaluation of Accuracy in a Single Center
title_short Freehand Insertion of External Ventricular Drainage Catheter: Evaluation of Accuracy in a Single Center
title_sort freehand insertion of external ventricular drainage catheter: evaluation of accuracy in a single center
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7057862/
https://www.ncbi.nlm.nih.gov/pubmed/32181172
http://dx.doi.org/10.4103/ajns.AJNS_292_19
work_keys_str_mv AT leekengsiang freehandinsertionofexternalventriculardrainagecatheterevaluationofaccuracyinasinglecenter
AT zhangjohnjiongyang freehandinsertionofexternalventriculardrainagecatheterevaluationofaccuracyinasinglecenter
AT bolemnagarjun freehandinsertionofexternalventriculardrainagecatheterevaluationofaccuracyinasinglecenter
AT leongmaylian freehandinsertionofexternalventriculardrainagecatheterevaluationofaccuracyinasinglecenter
AT gohchunpeng freehandinsertionofexternalventriculardrainagecatheterevaluationofaccuracyinasinglecenter
AT hassanrashidul freehandinsertionofexternalventriculardrainagecatheterevaluationofaccuracyinasinglecenter
AT salekalaminmaa freehandinsertionofexternalventriculardrainagecatheterevaluationofaccuracyinasinglecenter
AT seinlwinasherpaultan freehandinsertionofexternalventriculardrainagecatheterevaluationofaccuracyinasinglecenter
AT teokejia freehandinsertionofexternalventriculardrainagecatheterevaluationofaccuracyinasinglecenter
AT chouning freehandinsertionofexternalventriculardrainagecatheterevaluationofaccuracyinasinglecenter
AT ngavincent freehandinsertionofexternalventriculardrainagecatheterevaluationofaccuracyinasinglecenter
AT yeotsengtsai freehandinsertionofexternalventriculardrainagecatheterevaluationofaccuracyinasinglecenter