Cargando…

Progress in automating patch clamp cellular physiology

Patch clamp electrophysiology has transformed research in the life sciences over the last few decades. Since their inception, automatic patch clamp platforms have evolved considerably, demonstrating the capability to address both voltage- and ligand-gated channels, and showing the potential to play...

Descripción completa

Detalles Bibliográficos
Autores principales: Annecchino, Luca A., Schultz, Simon R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7058203/
https://www.ncbi.nlm.nih.gov/pubmed/32166142
http://dx.doi.org/10.1177/2398212818776561
_version_ 1783503817327771648
author Annecchino, Luca A.
Schultz, Simon R.
author_facet Annecchino, Luca A.
Schultz, Simon R.
author_sort Annecchino, Luca A.
collection PubMed
description Patch clamp electrophysiology has transformed research in the life sciences over the last few decades. Since their inception, automatic patch clamp platforms have evolved considerably, demonstrating the capability to address both voltage- and ligand-gated channels, and showing the potential to play a pivotal role in drug discovery and biomedical research. Unfortunately, the cell suspension assays to which early systems were limited cannot recreate biologically relevant cellular environments, or capture higher order aspects of synaptic physiology and network dynamics. In vivo patch clamp electrophysiology has the potential to yield more biologically complex information and be especially useful in reverse engineering the molecular and cellular mechanisms of single-cell and network neuronal computation, while capturing important aspects of human disease mechanisms and possible therapeutic strategies. Unfortunately, it is a difficult procedure with a steep learning curve, which has restricted dissemination of the technique. Luckily, in vivo patch clamp electrophysiology seems particularly amenable to robotic automation. In this review, we document the development of automated patch clamp technology, from early systems based on multi-well plates through to automated planar-array platforms, and modern robotic platforms capable of performing two-photon targeted whole-cell electrophysiological recordings in vivo.
format Online
Article
Text
id pubmed-7058203
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-70582032020-03-12 Progress in automating patch clamp cellular physiology Annecchino, Luca A. Schultz, Simon R. Brain Neurosci Adv Review Article Patch clamp electrophysiology has transformed research in the life sciences over the last few decades. Since their inception, automatic patch clamp platforms have evolved considerably, demonstrating the capability to address both voltage- and ligand-gated channels, and showing the potential to play a pivotal role in drug discovery and biomedical research. Unfortunately, the cell suspension assays to which early systems were limited cannot recreate biologically relevant cellular environments, or capture higher order aspects of synaptic physiology and network dynamics. In vivo patch clamp electrophysiology has the potential to yield more biologically complex information and be especially useful in reverse engineering the molecular and cellular mechanisms of single-cell and network neuronal computation, while capturing important aspects of human disease mechanisms and possible therapeutic strategies. Unfortunately, it is a difficult procedure with a steep learning curve, which has restricted dissemination of the technique. Luckily, in vivo patch clamp electrophysiology seems particularly amenable to robotic automation. In this review, we document the development of automated patch clamp technology, from early systems based on multi-well plates through to automated planar-array platforms, and modern robotic platforms capable of performing two-photon targeted whole-cell electrophysiological recordings in vivo. SAGE Publications 2018-05-17 /pmc/articles/PMC7058203/ /pubmed/32166142 http://dx.doi.org/10.1177/2398212818776561 Text en © The Author(s) 2018 http://creativecommons.org/licenses/by/4.0/ This article is distributed under the terms of the Creative Commons Attribution 4.0 License (http://www.creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Review Article
Annecchino, Luca A.
Schultz, Simon R.
Progress in automating patch clamp cellular physiology
title Progress in automating patch clamp cellular physiology
title_full Progress in automating patch clamp cellular physiology
title_fullStr Progress in automating patch clamp cellular physiology
title_full_unstemmed Progress in automating patch clamp cellular physiology
title_short Progress in automating patch clamp cellular physiology
title_sort progress in automating patch clamp cellular physiology
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7058203/
https://www.ncbi.nlm.nih.gov/pubmed/32166142
http://dx.doi.org/10.1177/2398212818776561
work_keys_str_mv AT annecchinolucaa progressinautomatingpatchclampcellularphysiology
AT schultzsimonr progressinautomatingpatchclampcellularphysiology