Cargando…

Cardiovascular magnetic resonance 4D flow analysis has a higher diagnostic yield than Doppler echocardiography for detecting increased pulmonary artery pressure

BACKGROUND: Pulmonary hypertension is definitively diagnosed by the measurement of mean pulmonary artery (PA) pressure (mPAP) using right heart catheterization. Cardiovascular magnetic resonance (CMR) four-dimensional (4D) flow analysis can estimate mPAP from blood flow vortex duration in the PA, wi...

Descripción completa

Detalles Bibliográficos
Autores principales: Ramos, Joao G., Fyrdahl, Alexander, Wieslander, Björn, Reiter, Gert, Reiter, Ursula, Jin, Ning, Maret, Eva, Eriksson, Maria, Caidahl, Kenneth, Sörensson, Peder, Sigfridsson, Andreas, Ugander, Martin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7060590/
https://www.ncbi.nlm.nih.gov/pubmed/32143594
http://dx.doi.org/10.1186/s12880-020-00428-9
_version_ 1783504264208842752
author Ramos, Joao G.
Fyrdahl, Alexander
Wieslander, Björn
Reiter, Gert
Reiter, Ursula
Jin, Ning
Maret, Eva
Eriksson, Maria
Caidahl, Kenneth
Sörensson, Peder
Sigfridsson, Andreas
Ugander, Martin
author_facet Ramos, Joao G.
Fyrdahl, Alexander
Wieslander, Björn
Reiter, Gert
Reiter, Ursula
Jin, Ning
Maret, Eva
Eriksson, Maria
Caidahl, Kenneth
Sörensson, Peder
Sigfridsson, Andreas
Ugander, Martin
author_sort Ramos, Joao G.
collection PubMed
description BACKGROUND: Pulmonary hypertension is definitively diagnosed by the measurement of mean pulmonary artery (PA) pressure (mPAP) using right heart catheterization. Cardiovascular magnetic resonance (CMR) four-dimensional (4D) flow analysis can estimate mPAP from blood flow vortex duration in the PA, with excellent results. Moreover, the peak systolic tricuspid regurgitation (TR) pressure gradient (TRPG) measured by Doppler echocardiography is commonly used in clinical routine to estimate systolic PA pressure. This study aimed to compare CMR and echocardiography with regards to quantitative and categorical agreement, and diagnostic yield for detecting increased PA pressure. METHODS: Consecutive clinically referred patients (n = 60, median [interquartile range] age 60 [48–68] years, 33% female) underwent echocardiography and CMR at 1.5 T (n = 43) or 3 T (n = 17). PA vortex duration was used to estimate mPAP using a commercially available time-resolved multiple 2D slice phase contrast three-directional velocity encoded sequence covering the main PA. Transthoracic Doppler echocardiography was performed to measure TR and derive TRPG. Diagnostic yield was defined as the fraction of cases in which CMR or echocardiography detected an increased PA pressure, defined as vortex duration ≥15% of the cardiac cycle (mPAP ≥25 mmHg) or TR velocity > 2.8 m/s (TRPG > 31 mmHg). RESULTS: Both CMR and echocardiography showed normal PA pressure in 39/60 (65%) patients and increased PA pressure in 9/60 (15%) patients, overall agreement in 48/60 (80%) patients, kappa 0.49 (95% confidence interval 0.27–0.71). CMR had a higher diagnostic yield for detecting increased PA pressure compared to echocardiography (21/60 (35%) vs 9/60 (15%), p < 0.001). In cases with both an observable PA vortex and measurable TR velocity (34/60, 56%), TRPG was correlated with mPAP (R(2) = 0.65, p < 0.001). CONCLUSIONS: There is good quantitative and fair categorical agreement between estimated mPAP from CMR and TRPG from echocardiography. CMR has higher diagnostic yield for detecting increased PA pressure compared to echocardiography, potentially due to a lower sensitivity of echocardiography in detecting increased PA pressure compared to CMR, related to limitations in the ability to adequately visualize and measure the TR jet by echocardiography. Future comparison between echocardiography, CMR and invasive measurements are justified to definitively confirm these findings.
format Online
Article
Text
id pubmed-7060590
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-70605902020-03-12 Cardiovascular magnetic resonance 4D flow analysis has a higher diagnostic yield than Doppler echocardiography for detecting increased pulmonary artery pressure Ramos, Joao G. Fyrdahl, Alexander Wieslander, Björn Reiter, Gert Reiter, Ursula Jin, Ning Maret, Eva Eriksson, Maria Caidahl, Kenneth Sörensson, Peder Sigfridsson, Andreas Ugander, Martin BMC Med Imaging Research Article BACKGROUND: Pulmonary hypertension is definitively diagnosed by the measurement of mean pulmonary artery (PA) pressure (mPAP) using right heart catheterization. Cardiovascular magnetic resonance (CMR) four-dimensional (4D) flow analysis can estimate mPAP from blood flow vortex duration in the PA, with excellent results. Moreover, the peak systolic tricuspid regurgitation (TR) pressure gradient (TRPG) measured by Doppler echocardiography is commonly used in clinical routine to estimate systolic PA pressure. This study aimed to compare CMR and echocardiography with regards to quantitative and categorical agreement, and diagnostic yield for detecting increased PA pressure. METHODS: Consecutive clinically referred patients (n = 60, median [interquartile range] age 60 [48–68] years, 33% female) underwent echocardiography and CMR at 1.5 T (n = 43) or 3 T (n = 17). PA vortex duration was used to estimate mPAP using a commercially available time-resolved multiple 2D slice phase contrast three-directional velocity encoded sequence covering the main PA. Transthoracic Doppler echocardiography was performed to measure TR and derive TRPG. Diagnostic yield was defined as the fraction of cases in which CMR or echocardiography detected an increased PA pressure, defined as vortex duration ≥15% of the cardiac cycle (mPAP ≥25 mmHg) or TR velocity > 2.8 m/s (TRPG > 31 mmHg). RESULTS: Both CMR and echocardiography showed normal PA pressure in 39/60 (65%) patients and increased PA pressure in 9/60 (15%) patients, overall agreement in 48/60 (80%) patients, kappa 0.49 (95% confidence interval 0.27–0.71). CMR had a higher diagnostic yield for detecting increased PA pressure compared to echocardiography (21/60 (35%) vs 9/60 (15%), p < 0.001). In cases with both an observable PA vortex and measurable TR velocity (34/60, 56%), TRPG was correlated with mPAP (R(2) = 0.65, p < 0.001). CONCLUSIONS: There is good quantitative and fair categorical agreement between estimated mPAP from CMR and TRPG from echocardiography. CMR has higher diagnostic yield for detecting increased PA pressure compared to echocardiography, potentially due to a lower sensitivity of echocardiography in detecting increased PA pressure compared to CMR, related to limitations in the ability to adequately visualize and measure the TR jet by echocardiography. Future comparison between echocardiography, CMR and invasive measurements are justified to definitively confirm these findings. BioMed Central 2020-03-06 /pmc/articles/PMC7060590/ /pubmed/32143594 http://dx.doi.org/10.1186/s12880-020-00428-9 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Ramos, Joao G.
Fyrdahl, Alexander
Wieslander, Björn
Reiter, Gert
Reiter, Ursula
Jin, Ning
Maret, Eva
Eriksson, Maria
Caidahl, Kenneth
Sörensson, Peder
Sigfridsson, Andreas
Ugander, Martin
Cardiovascular magnetic resonance 4D flow analysis has a higher diagnostic yield than Doppler echocardiography for detecting increased pulmonary artery pressure
title Cardiovascular magnetic resonance 4D flow analysis has a higher diagnostic yield than Doppler echocardiography for detecting increased pulmonary artery pressure
title_full Cardiovascular magnetic resonance 4D flow analysis has a higher diagnostic yield than Doppler echocardiography for detecting increased pulmonary artery pressure
title_fullStr Cardiovascular magnetic resonance 4D flow analysis has a higher diagnostic yield than Doppler echocardiography for detecting increased pulmonary artery pressure
title_full_unstemmed Cardiovascular magnetic resonance 4D flow analysis has a higher diagnostic yield than Doppler echocardiography for detecting increased pulmonary artery pressure
title_short Cardiovascular magnetic resonance 4D flow analysis has a higher diagnostic yield than Doppler echocardiography for detecting increased pulmonary artery pressure
title_sort cardiovascular magnetic resonance 4d flow analysis has a higher diagnostic yield than doppler echocardiography for detecting increased pulmonary artery pressure
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7060590/
https://www.ncbi.nlm.nih.gov/pubmed/32143594
http://dx.doi.org/10.1186/s12880-020-00428-9
work_keys_str_mv AT ramosjoaog cardiovascularmagneticresonance4dflowanalysishasahigherdiagnosticyieldthandopplerechocardiographyfordetectingincreasedpulmonaryarterypressure
AT fyrdahlalexander cardiovascularmagneticresonance4dflowanalysishasahigherdiagnosticyieldthandopplerechocardiographyfordetectingincreasedpulmonaryarterypressure
AT wieslanderbjorn cardiovascularmagneticresonance4dflowanalysishasahigherdiagnosticyieldthandopplerechocardiographyfordetectingincreasedpulmonaryarterypressure
AT reitergert cardiovascularmagneticresonance4dflowanalysishasahigherdiagnosticyieldthandopplerechocardiographyfordetectingincreasedpulmonaryarterypressure
AT reiterursula cardiovascularmagneticresonance4dflowanalysishasahigherdiagnosticyieldthandopplerechocardiographyfordetectingincreasedpulmonaryarterypressure
AT jinning cardiovascularmagneticresonance4dflowanalysishasahigherdiagnosticyieldthandopplerechocardiographyfordetectingincreasedpulmonaryarterypressure
AT mareteva cardiovascularmagneticresonance4dflowanalysishasahigherdiagnosticyieldthandopplerechocardiographyfordetectingincreasedpulmonaryarterypressure
AT erikssonmaria cardiovascularmagneticresonance4dflowanalysishasahigherdiagnosticyieldthandopplerechocardiographyfordetectingincreasedpulmonaryarterypressure
AT caidahlkenneth cardiovascularmagneticresonance4dflowanalysishasahigherdiagnosticyieldthandopplerechocardiographyfordetectingincreasedpulmonaryarterypressure
AT sorenssonpeder cardiovascularmagneticresonance4dflowanalysishasahigherdiagnosticyieldthandopplerechocardiographyfordetectingincreasedpulmonaryarterypressure
AT sigfridssonandreas cardiovascularmagneticresonance4dflowanalysishasahigherdiagnosticyieldthandopplerechocardiographyfordetectingincreasedpulmonaryarterypressure
AT ugandermartin cardiovascularmagneticresonance4dflowanalysishasahigherdiagnosticyieldthandopplerechocardiographyfordetectingincreasedpulmonaryarterypressure