Cargando…

Association of Obesity Measures with Atrial Fibrillation Recurrence After Cryoablation in Patients with Paroxysmal Atrial Fibrillation

BACKGROUND: Obesity increases the risk of atrial fibrillation (AF) recurrence after ablation. This study explored the relationship between various obesity indexes and risk of recurrence after cryoablation of paroxysmal AF (PAF). MATERIAL/METHODS: Our prospective study included 100 patients with PAF...

Descripción completa

Detalles Bibliográficos
Autores principales: Shang, Luxiang, Shao, Mengjiao, Guo, Qilong, Xiaokereti, Jiasuoer, Zhao, Yang, Lu, Yanmei, Zhang, Ling, Tang, Baopeng, Zhou, Xianhui
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7061586/
https://www.ncbi.nlm.nih.gov/pubmed/32102988
http://dx.doi.org/10.12659/MSM.920429
_version_ 1783504417254801408
author Shang, Luxiang
Shao, Mengjiao
Guo, Qilong
Xiaokereti, Jiasuoer
Zhao, Yang
Lu, Yanmei
Zhang, Ling
Tang, Baopeng
Zhou, Xianhui
author_facet Shang, Luxiang
Shao, Mengjiao
Guo, Qilong
Xiaokereti, Jiasuoer
Zhao, Yang
Lu, Yanmei
Zhang, Ling
Tang, Baopeng
Zhou, Xianhui
author_sort Shang, Luxiang
collection PubMed
description BACKGROUND: Obesity increases the risk of atrial fibrillation (AF) recurrence after ablation. This study explored the relationship between various obesity indexes and risk of recurrence after cryoablation of paroxysmal AF (PAF). MATERIAL/METHODS: Our prospective study included 100 patients with PAF who underwent first cryoablation. Physical examination and fasting blood lipids levels were measured at baseline. Seven obesity indexes were determined: body mass index (BMI), waist circumference (WC), waist-to-height ratio (WHtR), waist-hip ratio (WHR), cardiometabolic index (CMI), lipid accumulation product (LAP), and body adiposity index (BAI). AF recurrence was confirmed by electrocardiograms and Holter monitor at follow-up visits after the initial 3-month blanking period. Receiver operating characteristic (ROC) curves were drawn to assess the abilities of obesity indicators in predicting AF recurrence. Multivariable Cox regression analysis was used to examine independent predictors of AF recurrence. RESULTS: During a mean follow-up of 13.4 months, 31 patients (31.0%) had recurrent AF. Patients with recurrence had higher BMI, WC, WHtR, LAP, and BAI compared with those without recurrence. ROC analysis indicated the potential predictive value of BAI with an AUC of 0.657 (95% confidence interval [CI]: 0.534–0.779), followed by WC, WHtR, LAP, and BMI (all P<0.05). Diagnosis-to-ablation time (HR 1.034, 95% CI: 1.002–1.068), left atrial diameter (HR 1.147, 95% CI: 1.026–1.281), and WC (HR 1.026, 95% CI: 1.000–1.053) were independent predictive factors for AF recurrence after multivariable adjustment. CONCLUSIONS: In this study population, WC appears to be a potential indicator for the prediction of recurrence in patients with PAF after cryoablation.
format Online
Article
Text
id pubmed-7061586
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-70615862020-03-18 Association of Obesity Measures with Atrial Fibrillation Recurrence After Cryoablation in Patients with Paroxysmal Atrial Fibrillation Shang, Luxiang Shao, Mengjiao Guo, Qilong Xiaokereti, Jiasuoer Zhao, Yang Lu, Yanmei Zhang, Ling Tang, Baopeng Zhou, Xianhui Med Sci Monit Clinical Research BACKGROUND: Obesity increases the risk of atrial fibrillation (AF) recurrence after ablation. This study explored the relationship between various obesity indexes and risk of recurrence after cryoablation of paroxysmal AF (PAF). MATERIAL/METHODS: Our prospective study included 100 patients with PAF who underwent first cryoablation. Physical examination and fasting blood lipids levels were measured at baseline. Seven obesity indexes were determined: body mass index (BMI), waist circumference (WC), waist-to-height ratio (WHtR), waist-hip ratio (WHR), cardiometabolic index (CMI), lipid accumulation product (LAP), and body adiposity index (BAI). AF recurrence was confirmed by electrocardiograms and Holter monitor at follow-up visits after the initial 3-month blanking period. Receiver operating characteristic (ROC) curves were drawn to assess the abilities of obesity indicators in predicting AF recurrence. Multivariable Cox regression analysis was used to examine independent predictors of AF recurrence. RESULTS: During a mean follow-up of 13.4 months, 31 patients (31.0%) had recurrent AF. Patients with recurrence had higher BMI, WC, WHtR, LAP, and BAI compared with those without recurrence. ROC analysis indicated the potential predictive value of BAI with an AUC of 0.657 (95% confidence interval [CI]: 0.534–0.779), followed by WC, WHtR, LAP, and BMI (all P<0.05). Diagnosis-to-ablation time (HR 1.034, 95% CI: 1.002–1.068), left atrial diameter (HR 1.147, 95% CI: 1.026–1.281), and WC (HR 1.026, 95% CI: 1.000–1.053) were independent predictive factors for AF recurrence after multivariable adjustment. CONCLUSIONS: In this study population, WC appears to be a potential indicator for the prediction of recurrence in patients with PAF after cryoablation. International Scientific Literature, Inc. 2020-02-27 /pmc/articles/PMC7061586/ /pubmed/32102988 http://dx.doi.org/10.12659/MSM.920429 Text en © Med Sci Monit, 2020 This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) )
spellingShingle Clinical Research
Shang, Luxiang
Shao, Mengjiao
Guo, Qilong
Xiaokereti, Jiasuoer
Zhao, Yang
Lu, Yanmei
Zhang, Ling
Tang, Baopeng
Zhou, Xianhui
Association of Obesity Measures with Atrial Fibrillation Recurrence After Cryoablation in Patients with Paroxysmal Atrial Fibrillation
title Association of Obesity Measures with Atrial Fibrillation Recurrence After Cryoablation in Patients with Paroxysmal Atrial Fibrillation
title_full Association of Obesity Measures with Atrial Fibrillation Recurrence After Cryoablation in Patients with Paroxysmal Atrial Fibrillation
title_fullStr Association of Obesity Measures with Atrial Fibrillation Recurrence After Cryoablation in Patients with Paroxysmal Atrial Fibrillation
title_full_unstemmed Association of Obesity Measures with Atrial Fibrillation Recurrence After Cryoablation in Patients with Paroxysmal Atrial Fibrillation
title_short Association of Obesity Measures with Atrial Fibrillation Recurrence After Cryoablation in Patients with Paroxysmal Atrial Fibrillation
title_sort association of obesity measures with atrial fibrillation recurrence after cryoablation in patients with paroxysmal atrial fibrillation
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7061586/
https://www.ncbi.nlm.nih.gov/pubmed/32102988
http://dx.doi.org/10.12659/MSM.920429
work_keys_str_mv AT shangluxiang associationofobesitymeasureswithatrialfibrillationrecurrenceaftercryoablationinpatientswithparoxysmalatrialfibrillation
AT shaomengjiao associationofobesitymeasureswithatrialfibrillationrecurrenceaftercryoablationinpatientswithparoxysmalatrialfibrillation
AT guoqilong associationofobesitymeasureswithatrialfibrillationrecurrenceaftercryoablationinpatientswithparoxysmalatrialfibrillation
AT xiaokeretijiasuoer associationofobesitymeasureswithatrialfibrillationrecurrenceaftercryoablationinpatientswithparoxysmalatrialfibrillation
AT zhaoyang associationofobesitymeasureswithatrialfibrillationrecurrenceaftercryoablationinpatientswithparoxysmalatrialfibrillation
AT luyanmei associationofobesitymeasureswithatrialfibrillationrecurrenceaftercryoablationinpatientswithparoxysmalatrialfibrillation
AT zhangling associationofobesitymeasureswithatrialfibrillationrecurrenceaftercryoablationinpatientswithparoxysmalatrialfibrillation
AT tangbaopeng associationofobesitymeasureswithatrialfibrillationrecurrenceaftercryoablationinpatientswithparoxysmalatrialfibrillation
AT zhouxianhui associationofobesitymeasureswithatrialfibrillationrecurrenceaftercryoablationinpatientswithparoxysmalatrialfibrillation