Cargando…

Interobserver reproducibility of the PRECISE scoring system for prostate MRI on active surveillance: results from a two-centre pilot study

OBJECTIVES: We aimed to determine the interobserver reproducibility of the Prostate Cancer Radiological Estimation of Change in Sequential Evaluation (PRECISE) criteria for magnetic resonance imaging in patients on active surveillance (AS) for prostate cancer (PCa) at two different academic centres....

Descripción completa

Detalles Bibliográficos
Autores principales: Giganti, Francesco, Pecoraro, Martina, Stavrinides, Vasilis, Stabile, Armando, Cipollari, Stefano, Sciarra, Alessandro, Kirkham, Alex, Allen, Clare, Punwani, Shonit, Emberton, Mark, Catalano, Carlo, Moore, Caroline M., Panebianco, Valeria
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7062656/
https://www.ncbi.nlm.nih.gov/pubmed/31844959
http://dx.doi.org/10.1007/s00330-019-06557-2
_version_ 1783504551276445696
author Giganti, Francesco
Pecoraro, Martina
Stavrinides, Vasilis
Stabile, Armando
Cipollari, Stefano
Sciarra, Alessandro
Kirkham, Alex
Allen, Clare
Punwani, Shonit
Emberton, Mark
Catalano, Carlo
Moore, Caroline M.
Panebianco, Valeria
author_facet Giganti, Francesco
Pecoraro, Martina
Stavrinides, Vasilis
Stabile, Armando
Cipollari, Stefano
Sciarra, Alessandro
Kirkham, Alex
Allen, Clare
Punwani, Shonit
Emberton, Mark
Catalano, Carlo
Moore, Caroline M.
Panebianco, Valeria
author_sort Giganti, Francesco
collection PubMed
description OBJECTIVES: We aimed to determine the interobserver reproducibility of the Prostate Cancer Radiological Estimation of Change in Sequential Evaluation (PRECISE) criteria for magnetic resonance imaging in patients on active surveillance (AS) for prostate cancer (PCa) at two different academic centres. METHODS: The PRECISE criteria score the likelihood of clinically significant change over time. The system is a 1-to-5 scale, where 1 or 2 implies regression of a previously visible lesion, 3 denotes stability and 4 or 5 indicates radiological progression. A retrospective analysis of 80 patients (40 from each centre) on AS with a biopsy-confirmed low- or intermediate-risk PCa (i.e. ≤ Gleason 3 + 4 and prostate-specific antigen ≤ 20 ng/ml) and ≥ 2 prostate MR scans was performed. Two blinded radiologists reported all scans independently and scored the likelihood of radiological change (PRECISE score) from the second scan onwards. Cohen’s κ coefficients and percent agreement were computed. RESULTS: Agreement was substantial both at a per-patient and a per-scan level (κ = 0.71 and 0.61; percent agreement = 79% and 81%, respectively) for each PRECISE score. The agreement was superior (κ = 0.83 and 0.67; percent agreement = 90% and 91%, respectively) when the PRECISE scores were grouped according to the absence/presence of radiological progression (PRECISE 1–3 vs 4–5). Higher inter-reader agreement was observed for the scans performed at University College London (UCL) (κ = 0.81 vs 0.55 on a per-patient level and κ = 0.70 vs 0.48 on a per-scan level, respectively). The discrepancies between institutions were less evident for percent agreement (80% vs 78% and 86% vs 75%, respectively). CONCLUSIONS: Expert radiologists achieved substantial reproducibility for the PRECISE scoring system, especially when data were pooled together according to the absence/presence of radiological progression (PRECISE 1–3 vs 4–5). KEY POINTS: • Inter-reader agreement between two experienced prostate radiologists using the PRECISE criteria was substantial. • The agreement was higher when the PRECISE scores were grouped according to the absence/presence of radiological progression (i.e. PRECISE 1–3 vs PRECISE 4 and 5). • Higher inter-reader agreement was observed for the scans performed at UCL, but the discrepancies between institutions were less evident for percent agreement.
format Online
Article
Text
id pubmed-7062656
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-70626562020-03-23 Interobserver reproducibility of the PRECISE scoring system for prostate MRI on active surveillance: results from a two-centre pilot study Giganti, Francesco Pecoraro, Martina Stavrinides, Vasilis Stabile, Armando Cipollari, Stefano Sciarra, Alessandro Kirkham, Alex Allen, Clare Punwani, Shonit Emberton, Mark Catalano, Carlo Moore, Caroline M. Panebianco, Valeria Eur Radiol Urogenital OBJECTIVES: We aimed to determine the interobserver reproducibility of the Prostate Cancer Radiological Estimation of Change in Sequential Evaluation (PRECISE) criteria for magnetic resonance imaging in patients on active surveillance (AS) for prostate cancer (PCa) at two different academic centres. METHODS: The PRECISE criteria score the likelihood of clinically significant change over time. The system is a 1-to-5 scale, where 1 or 2 implies regression of a previously visible lesion, 3 denotes stability and 4 or 5 indicates radiological progression. A retrospective analysis of 80 patients (40 from each centre) on AS with a biopsy-confirmed low- or intermediate-risk PCa (i.e. ≤ Gleason 3 + 4 and prostate-specific antigen ≤ 20 ng/ml) and ≥ 2 prostate MR scans was performed. Two blinded radiologists reported all scans independently and scored the likelihood of radiological change (PRECISE score) from the second scan onwards. Cohen’s κ coefficients and percent agreement were computed. RESULTS: Agreement was substantial both at a per-patient and a per-scan level (κ = 0.71 and 0.61; percent agreement = 79% and 81%, respectively) for each PRECISE score. The agreement was superior (κ = 0.83 and 0.67; percent agreement = 90% and 91%, respectively) when the PRECISE scores were grouped according to the absence/presence of radiological progression (PRECISE 1–3 vs 4–5). Higher inter-reader agreement was observed for the scans performed at University College London (UCL) (κ = 0.81 vs 0.55 on a per-patient level and κ = 0.70 vs 0.48 on a per-scan level, respectively). The discrepancies between institutions were less evident for percent agreement (80% vs 78% and 86% vs 75%, respectively). CONCLUSIONS: Expert radiologists achieved substantial reproducibility for the PRECISE scoring system, especially when data were pooled together according to the absence/presence of radiological progression (PRECISE 1–3 vs 4–5). KEY POINTS: • Inter-reader agreement between two experienced prostate radiologists using the PRECISE criteria was substantial. • The agreement was higher when the PRECISE scores were grouped according to the absence/presence of radiological progression (i.e. PRECISE 1–3 vs PRECISE 4 and 5). • Higher inter-reader agreement was observed for the scans performed at UCL, but the discrepancies between institutions were less evident for percent agreement. Springer Berlin Heidelberg 2019-12-16 2020 /pmc/articles/PMC7062656/ /pubmed/31844959 http://dx.doi.org/10.1007/s00330-019-06557-2 Text en © The Author(s) 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Urogenital
Giganti, Francesco
Pecoraro, Martina
Stavrinides, Vasilis
Stabile, Armando
Cipollari, Stefano
Sciarra, Alessandro
Kirkham, Alex
Allen, Clare
Punwani, Shonit
Emberton, Mark
Catalano, Carlo
Moore, Caroline M.
Panebianco, Valeria
Interobserver reproducibility of the PRECISE scoring system for prostate MRI on active surveillance: results from a two-centre pilot study
title Interobserver reproducibility of the PRECISE scoring system for prostate MRI on active surveillance: results from a two-centre pilot study
title_full Interobserver reproducibility of the PRECISE scoring system for prostate MRI on active surveillance: results from a two-centre pilot study
title_fullStr Interobserver reproducibility of the PRECISE scoring system for prostate MRI on active surveillance: results from a two-centre pilot study
title_full_unstemmed Interobserver reproducibility of the PRECISE scoring system for prostate MRI on active surveillance: results from a two-centre pilot study
title_short Interobserver reproducibility of the PRECISE scoring system for prostate MRI on active surveillance: results from a two-centre pilot study
title_sort interobserver reproducibility of the precise scoring system for prostate mri on active surveillance: results from a two-centre pilot study
topic Urogenital
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7062656/
https://www.ncbi.nlm.nih.gov/pubmed/31844959
http://dx.doi.org/10.1007/s00330-019-06557-2
work_keys_str_mv AT gigantifrancesco interobserverreproducibilityoftheprecisescoringsystemforprostatemrionactivesurveillanceresultsfromatwocentrepilotstudy
AT pecoraromartina interobserverreproducibilityoftheprecisescoringsystemforprostatemrionactivesurveillanceresultsfromatwocentrepilotstudy
AT stavrinidesvasilis interobserverreproducibilityoftheprecisescoringsystemforprostatemrionactivesurveillanceresultsfromatwocentrepilotstudy
AT stabilearmando interobserverreproducibilityoftheprecisescoringsystemforprostatemrionactivesurveillanceresultsfromatwocentrepilotstudy
AT cipollaristefano interobserverreproducibilityoftheprecisescoringsystemforprostatemrionactivesurveillanceresultsfromatwocentrepilotstudy
AT sciarraalessandro interobserverreproducibilityoftheprecisescoringsystemforprostatemrionactivesurveillanceresultsfromatwocentrepilotstudy
AT kirkhamalex interobserverreproducibilityoftheprecisescoringsystemforprostatemrionactivesurveillanceresultsfromatwocentrepilotstudy
AT allenclare interobserverreproducibilityoftheprecisescoringsystemforprostatemrionactivesurveillanceresultsfromatwocentrepilotstudy
AT punwanishonit interobserverreproducibilityoftheprecisescoringsystemforprostatemrionactivesurveillanceresultsfromatwocentrepilotstudy
AT embertonmark interobserverreproducibilityoftheprecisescoringsystemforprostatemrionactivesurveillanceresultsfromatwocentrepilotstudy
AT catalanocarlo interobserverreproducibilityoftheprecisescoringsystemforprostatemrionactivesurveillanceresultsfromatwocentrepilotstudy
AT moorecarolinem interobserverreproducibilityoftheprecisescoringsystemforprostatemrionactivesurveillanceresultsfromatwocentrepilotstudy
AT panebiancovaleria interobserverreproducibilityoftheprecisescoringsystemforprostatemrionactivesurveillanceresultsfromatwocentrepilotstudy