An investigation into the effect of changing the computed tomography slice reconstruction interval on the spatial replication accuracy of three‐dimensional printed anatomical models constructed by fused deposition modelling

INTRODUCTION: Three‐dimensional (3D) printed models can be constructed utilising computed tomography (CT) data. This project aimed to determine the effect of changing the slice reconstruction interval (SRI) on the spatial replication accuracy of 3D‐printed anatomical models constructed by fused depo...

Descripción completa

Detalles Bibliográficos
Autores principales: Searle, Ben, Starkey, Deborah
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7063250/
https://www.ncbi.nlm.nih.gov/pubmed/32056391
http://dx.doi.org/10.1002/jmrs.382
_version_ 1783504679774191616
author Searle, Ben
Starkey, Deborah
author_facet Searle, Ben
Starkey, Deborah
author_sort Searle, Ben
collection PubMed
description INTRODUCTION: Three‐dimensional (3D) printed models can be constructed utilising computed tomography (CT) data. This project aimed to determine the effect of changing the slice reconstruction interval (SRI) on the spatial replication accuracy of 3D‐printed anatomical models constructed by fused deposition modelling (FDM). METHODS: Three bovine vertebrae and an imaging phantom were imaged using a CT scanner. The Queensland State Government’s Animal Care and Protection Act 2001 did not apply as no animals were harmed to carry out scientific activity. The data were reconstructed into SRIs of 0.1, 0.3, 0.5 and 1 mm and processed by software before 3D printing. Specimens and printed models were measured with calipers to calculate mean absolute error prior to statistical analysis. RESULTS: Mean absolute error from the original models for the 0.1, 0.3, 0.5 and 1 mm 3D‐printed models was 0.592 ± 0.396 mm, 0.598 ± 0.479 mm, 0.712 ± 0.498 mm and 0.933 ± 0.457 mm, respectively. Paired t‐tests (P < 0.05) indicated a statistically significant difference between all original specimens and corresponding 3D‐printed models except the 0.1 mm vertebrae 2 (P = 0.061), 0.3 mm phantom 1 (P = 0.209) and 0.3 mm vertebrae 2 (P = 0.097). CONCLUSION: This study demonstrated that changing the SRI influences the spatial replication accuracy of 3D‐printed models constructed by FDM. Matching the SRI to the primary spatial resolution limiting factor of acquisition slice width or printer capabilities optimises replication accuracy.
format Online
Article
Text
id pubmed-7063250
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-70632502020-03-16 An investigation into the effect of changing the computed tomography slice reconstruction interval on the spatial replication accuracy of three‐dimensional printed anatomical models constructed by fused deposition modelling Searle, Ben Starkey, Deborah J Med Radiat Sci Original Articles INTRODUCTION: Three‐dimensional (3D) printed models can be constructed utilising computed tomography (CT) data. This project aimed to determine the effect of changing the slice reconstruction interval (SRI) on the spatial replication accuracy of 3D‐printed anatomical models constructed by fused deposition modelling (FDM). METHODS: Three bovine vertebrae and an imaging phantom were imaged using a CT scanner. The Queensland State Government’s Animal Care and Protection Act 2001 did not apply as no animals were harmed to carry out scientific activity. The data were reconstructed into SRIs of 0.1, 0.3, 0.5 and 1 mm and processed by software before 3D printing. Specimens and printed models were measured with calipers to calculate mean absolute error prior to statistical analysis. RESULTS: Mean absolute error from the original models for the 0.1, 0.3, 0.5 and 1 mm 3D‐printed models was 0.592 ± 0.396 mm, 0.598 ± 0.479 mm, 0.712 ± 0.498 mm and 0.933 ± 0.457 mm, respectively. Paired t‐tests (P < 0.05) indicated a statistically significant difference between all original specimens and corresponding 3D‐printed models except the 0.1 mm vertebrae 2 (P = 0.061), 0.3 mm phantom 1 (P = 0.209) and 0.3 mm vertebrae 2 (P = 0.097). CONCLUSION: This study demonstrated that changing the SRI influences the spatial replication accuracy of 3D‐printed models constructed by FDM. Matching the SRI to the primary spatial resolution limiting factor of acquisition slice width or printer capabilities optimises replication accuracy. John Wiley and Sons Inc. 2020-02-13 2020-03 /pmc/articles/PMC7063250/ /pubmed/32056391 http://dx.doi.org/10.1002/jmrs.382 Text en © 2020 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Original Articles
Searle, Ben
Starkey, Deborah
An investigation into the effect of changing the computed tomography slice reconstruction interval on the spatial replication accuracy of three‐dimensional printed anatomical models constructed by fused deposition modelling
title An investigation into the effect of changing the computed tomography slice reconstruction interval on the spatial replication accuracy of three‐dimensional printed anatomical models constructed by fused deposition modelling
title_full An investigation into the effect of changing the computed tomography slice reconstruction interval on the spatial replication accuracy of three‐dimensional printed anatomical models constructed by fused deposition modelling
title_fullStr An investigation into the effect of changing the computed tomography slice reconstruction interval on the spatial replication accuracy of three‐dimensional printed anatomical models constructed by fused deposition modelling
title_full_unstemmed An investigation into the effect of changing the computed tomography slice reconstruction interval on the spatial replication accuracy of three‐dimensional printed anatomical models constructed by fused deposition modelling
title_short An investigation into the effect of changing the computed tomography slice reconstruction interval on the spatial replication accuracy of three‐dimensional printed anatomical models constructed by fused deposition modelling
title_sort investigation into the effect of changing the computed tomography slice reconstruction interval on the spatial replication accuracy of three‐dimensional printed anatomical models constructed by fused deposition modelling
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7063250/
https://www.ncbi.nlm.nih.gov/pubmed/32056391
http://dx.doi.org/10.1002/jmrs.382
work_keys_str_mv AT searleben aninvestigationintotheeffectofchangingthecomputedtomographyslicereconstructionintervalonthespatialreplicationaccuracyofthreedimensionalprintedanatomicalmodelsconstructedbyfuseddepositionmodelling
AT starkeydeborah aninvestigationintotheeffectofchangingthecomputedtomographyslicereconstructionintervalonthespatialreplicationaccuracyofthreedimensionalprintedanatomicalmodelsconstructedbyfuseddepositionmodelling
AT searleben investigationintotheeffectofchangingthecomputedtomographyslicereconstructionintervalonthespatialreplicationaccuracyofthreedimensionalprintedanatomicalmodelsconstructedbyfuseddepositionmodelling
AT starkeydeborah investigationintotheeffectofchangingthecomputedtomographyslicereconstructionintervalonthespatialreplicationaccuracyofthreedimensionalprintedanatomicalmodelsconstructedbyfuseddepositionmodelling