Cargando…
Clinical Impact of an Electronic Dashboard and Alert System for Sedation Minimization and Ventilator Liberation: A Before-After Study
Sedation minimization and ventilator liberation protocols improve outcomes but are challenging to implement. We sought to demonstrate proof-of-concept and impact of an electronic application promoting sedation minimization and ventilator liberation. DESIGN: Multi-ICU proof-of-concept study and a sin...
Autores principales: | , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7063891/ https://www.ncbi.nlm.nih.gov/pubmed/32166237 http://dx.doi.org/10.1097/CCE.0000000000000057 |
Sumario: | Sedation minimization and ventilator liberation protocols improve outcomes but are challenging to implement. We sought to demonstrate proof-of-concept and impact of an electronic application promoting sedation minimization and ventilator liberation. DESIGN: Multi-ICU proof-of-concept study and a single ICU before-after study. SETTING: University hospital ICUs. PATIENTS: Adult patients receiving mechanical ventilation. INTERVENTIONS: An automated application consisting of 1) a web-based dashboard with real-time data on spontaneous breathing trial readiness, sedation depth, sedative infusions, and nudges to wean sedation and ventilatory support and 2) text-message alerts once patients met criteria for a spontaneous breathing trial and spontaneous awakening trial. Pre-intervention, sedation minimization, and ventilator liberation were reviewed daily during a multidisciplinary huddle. Post-intervention, the dashboard was used during the multidisciplinary huddle, throughout the day by respiratory therapists, and text alerts were sent to bedside providers. MEASUREMENTS AND MAIN RESULTS: We enrolled 115 subjects in the proof-of-concept study. Spontaneous breathing trial alerts were accurate (98.3%), usually sent while patients were receiving mandatory ventilation (88.5%), and 61.9% of patients received concurrent spontaneous awakening trial alerts. We enrolled 457 subjects in the before-after study, 221 pre-intervention and 236 post-intervention. After implementation, patients were 28% more likely to be extubated (hazard ratio, 1.28; 95% CI, 1.01–1.63; p = 0.042) and 31% more likely to be discharged from the ICU (hazard ratio, 1.31; 95% CI, 1.03–1.67; p = 0.027) at any time point. After implementation, the median duration of mechanical ventilation was 2.20 days (95% CI, 0.09–4.31 d; p = 0.042) shorter and the median ICU length of stay was 2.65 days (95% CI, 0.13–5.16 d; p = 0.040) shorter, compared with the expected durations without the application. CONCLUSIONS: Implementation of an electronic dashboard and alert system promoting sedation minimization and ventilator liberation was associated with reductions in the duration of mechanical ventilation and ICU length of stay. |
---|