Normothermic machine perfusion of ischaemically damaged porcine kidneys with autologous, allogeneic porcine and human red blood cells
In porcine kidney auto-transplant models, red blood cells (RBCs) are required for ex-vivo normothermic machine perfusion (NMP). As large quantities of RBCs are needed for NMP, utilising autologous RBCs would imply lethal exsanguination of the pig that is donor and recipient-to-be in the same experim...
Autores principales: | Pool, Merel B. F., Hartveld, Loes, Leuvenink, Henri G. D., Moers, Cyril |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7064242/ https://www.ncbi.nlm.nih.gov/pubmed/32155167 http://dx.doi.org/10.1371/journal.pone.0229566 |
Ejemplares similares
-
Prolonged Controlled Oxygenated Rewarming Improves Immediate Tubular Function and Energetic Recovery of Porcine Kidneys During Normothermic Machine Perfusion
por: Ogurlu, Baran, et al.
Publicado: (2022) -
Improved Normothermic Machine Perfusion After Short Oxygenated Hypothermic Machine Perfusion of Ischemically Injured Porcine Kidneys
por: Lignell, Stina, et al.
Publicado: (2021) -
Infusing Mesenchymal Stromal Cells into Porcine Kidneys during Normothermic Machine Perfusion: Intact MSCs Can Be Traced and Localised to Glomeruli
por: Pool, Merel, et al.
Publicado: (2019) -
Prolonged ex-vivo normothermic kidney perfusion: The impact of perfusate composition
por: Pool, Merel B. F., et al.
Publicado: (2021) -
Magnetic resonance imaging assessment of renal flow distribution patterns during ex vivo normothermic machine perfusion in porcine and human kidneys
por: Schutter, Rianne, et al.