Cargando…
Intra‐session and inter‐subject variability of 3D‐FID‐MRSI using single‐echo volumetric EPI navigators at 3T
PURPOSE: In this study, we demonstrate the first combination of 3D FID proton MRSI and spatial encoding via concentric‐ring trajectories (CRTs) at 3T. FID‐MRSI has many benefits including high detection sensitivity, in particular for J‐coupled metabolites (e.g., glutamate/glutamine). This makes it h...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7065144/ https://www.ncbi.nlm.nih.gov/pubmed/31721294 http://dx.doi.org/10.1002/mrm.28076 |
_version_ | 1783505007853699072 |
---|---|
author | Moser, Philipp Eckstein, Korbinian Hingerl, Lukas Weber, Michael Motyka, Stanislav Strasser, Bernhard van der Kouwe, Andre Robinson, Simon Trattnig, Siegfried Bogner, Wolfgang |
author_facet | Moser, Philipp Eckstein, Korbinian Hingerl, Lukas Weber, Michael Motyka, Stanislav Strasser, Bernhard van der Kouwe, Andre Robinson, Simon Trattnig, Siegfried Bogner, Wolfgang |
author_sort | Moser, Philipp |
collection | PubMed |
description | PURPOSE: In this study, we demonstrate the first combination of 3D FID proton MRSI and spatial encoding via concentric‐ring trajectories (CRTs) at 3T. FID‐MRSI has many benefits including high detection sensitivity, in particular for J‐coupled metabolites (e.g., glutamate/glutamine). This makes it highly attractive, not only for clinical, but also for, potentially, functional MRSI. However, this requires excellent reliability and temporal stability. We have, therefore, augmented this 3D‐FID‐MRSI sequence with single‐echo, imaging‐based volumetric navigators (se‐vNavs) for real‐time motion/shim‐correction (SHMOCO), which is 2× quicker than the original double‐echo navigators (de‐vNavs), hence allowing more efficient integration also in short‐TR sequences. METHODS: The tracking accuracy (position and B(0)‐field) of our proposed se‐vNavs was compared to the original de‐vNavs in phantoms (rest and translation) and in vivo (voluntary head rotation). Finally, the intra‐session stability of a 5:40 min 3D‐FID‐MRSI scan was evaluated with SHMOCO and no correction (NOCO) in 5 resting subjects. Intra/inter‐subject coefficients of variation (CV) and intra‐class correlations (ICC) over the whole 3D volume and in selected regions of interest ROI were assessed. RESULTS: Phantom and in vivo scans showed highly consistent tracking performance for se‐vNavs compared to the original de‐vNavs, but lower frequency drift. Up to ~30% better intra‐subject CVs were obtained for SHMOCO (P < 0.05), with values of 9.3/6.9/6.5/7.8% over the full VOI for Glx/tNAA/tCho/m‐Ins ratios to tCr. ICCs were good‐to‐high (91% for Glx/tCr in motor cortex), whereas the inter‐subject variability was ~11–19%. CONCLUSION: Real‐time motion/shim corrected 3D‐FID‐MRSI with time‐efficient CRT‐sampling at 3T allows reliable, high‐resolution metabolic imaging that is fast enough for clinical use and even, potentially, for functional MRSI. |
format | Online Article Text |
id | pubmed-7065144 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-70651442020-03-16 Intra‐session and inter‐subject variability of 3D‐FID‐MRSI using single‐echo volumetric EPI navigators at 3T Moser, Philipp Eckstein, Korbinian Hingerl, Lukas Weber, Michael Motyka, Stanislav Strasser, Bernhard van der Kouwe, Andre Robinson, Simon Trattnig, Siegfried Bogner, Wolfgang Magn Reson Med Note—Spectroscopic Methodology PURPOSE: In this study, we demonstrate the first combination of 3D FID proton MRSI and spatial encoding via concentric‐ring trajectories (CRTs) at 3T. FID‐MRSI has many benefits including high detection sensitivity, in particular for J‐coupled metabolites (e.g., glutamate/glutamine). This makes it highly attractive, not only for clinical, but also for, potentially, functional MRSI. However, this requires excellent reliability and temporal stability. We have, therefore, augmented this 3D‐FID‐MRSI sequence with single‐echo, imaging‐based volumetric navigators (se‐vNavs) for real‐time motion/shim‐correction (SHMOCO), which is 2× quicker than the original double‐echo navigators (de‐vNavs), hence allowing more efficient integration also in short‐TR sequences. METHODS: The tracking accuracy (position and B(0)‐field) of our proposed se‐vNavs was compared to the original de‐vNavs in phantoms (rest and translation) and in vivo (voluntary head rotation). Finally, the intra‐session stability of a 5:40 min 3D‐FID‐MRSI scan was evaluated with SHMOCO and no correction (NOCO) in 5 resting subjects. Intra/inter‐subject coefficients of variation (CV) and intra‐class correlations (ICC) over the whole 3D volume and in selected regions of interest ROI were assessed. RESULTS: Phantom and in vivo scans showed highly consistent tracking performance for se‐vNavs compared to the original de‐vNavs, but lower frequency drift. Up to ~30% better intra‐subject CVs were obtained for SHMOCO (P < 0.05), with values of 9.3/6.9/6.5/7.8% over the full VOI for Glx/tNAA/tCho/m‐Ins ratios to tCr. ICCs were good‐to‐high (91% for Glx/tCr in motor cortex), whereas the inter‐subject variability was ~11–19%. CONCLUSION: Real‐time motion/shim corrected 3D‐FID‐MRSI with time‐efficient CRT‐sampling at 3T allows reliable, high‐resolution metabolic imaging that is fast enough for clinical use and even, potentially, for functional MRSI. John Wiley and Sons Inc. 2019-11-13 2020-06 /pmc/articles/PMC7065144/ /pubmed/31721294 http://dx.doi.org/10.1002/mrm.28076 Text en © 2019 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Note—Spectroscopic Methodology Moser, Philipp Eckstein, Korbinian Hingerl, Lukas Weber, Michael Motyka, Stanislav Strasser, Bernhard van der Kouwe, Andre Robinson, Simon Trattnig, Siegfried Bogner, Wolfgang Intra‐session and inter‐subject variability of 3D‐FID‐MRSI using single‐echo volumetric EPI navigators at 3T |
title | Intra‐session and inter‐subject variability of 3D‐FID‐MRSI using single‐echo volumetric EPI navigators at 3T |
title_full | Intra‐session and inter‐subject variability of 3D‐FID‐MRSI using single‐echo volumetric EPI navigators at 3T |
title_fullStr | Intra‐session and inter‐subject variability of 3D‐FID‐MRSI using single‐echo volumetric EPI navigators at 3T |
title_full_unstemmed | Intra‐session and inter‐subject variability of 3D‐FID‐MRSI using single‐echo volumetric EPI navigators at 3T |
title_short | Intra‐session and inter‐subject variability of 3D‐FID‐MRSI using single‐echo volumetric EPI navigators at 3T |
title_sort | intra‐session and inter‐subject variability of 3d‐fid‐mrsi using single‐echo volumetric epi navigators at 3t |
topic | Note—Spectroscopic Methodology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7065144/ https://www.ncbi.nlm.nih.gov/pubmed/31721294 http://dx.doi.org/10.1002/mrm.28076 |
work_keys_str_mv | AT moserphilipp intrasessionandintersubjectvariabilityof3dfidmrsiusingsingleechovolumetricepinavigatorsat3t AT ecksteinkorbinian intrasessionandintersubjectvariabilityof3dfidmrsiusingsingleechovolumetricepinavigatorsat3t AT hingerllukas intrasessionandintersubjectvariabilityof3dfidmrsiusingsingleechovolumetricepinavigatorsat3t AT webermichael intrasessionandintersubjectvariabilityof3dfidmrsiusingsingleechovolumetricepinavigatorsat3t AT motykastanislav intrasessionandintersubjectvariabilityof3dfidmrsiusingsingleechovolumetricepinavigatorsat3t AT strasserbernhard intrasessionandintersubjectvariabilityof3dfidmrsiusingsingleechovolumetricepinavigatorsat3t AT vanderkouweandre intrasessionandintersubjectvariabilityof3dfidmrsiusingsingleechovolumetricepinavigatorsat3t AT robinsonsimon intrasessionandintersubjectvariabilityof3dfidmrsiusingsingleechovolumetricepinavigatorsat3t AT trattnigsiegfried intrasessionandintersubjectvariabilityof3dfidmrsiusingsingleechovolumetricepinavigatorsat3t AT bognerwolfgang intrasessionandintersubjectvariabilityof3dfidmrsiusingsingleechovolumetricepinavigatorsat3t |