A new M23-based ELISA assay for anti-aquaporin 4 autoantibodies: diagnostic accuracy and clinical correlation

PURPOSE: Although many assays have been developed to detect anti-aquaporin-4 (AQP4) antibodies, most of these assays require sophisticated techniques and are thus only available at specialized laboratories. The aim of this study was to evaluate the analytical and clinical performance of a new commer...

Descripción completa

Detalles Bibliográficos
Autores principales: Tampoia, Marilina, Abbracciavento, Letizia, Barberio, Giuseppina, Fabris, Martina, Bizzaro, Nicola
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7065340/
https://www.ncbi.nlm.nih.gov/pubmed/32257061
http://dx.doi.org/10.1186/s13317-019-0115-7
Descripción
Sumario:PURPOSE: Although many assays have been developed to detect anti-aquaporin-4 (AQP4) antibodies, most of these assays require sophisticated techniques and are thus only available at specialized laboratories. The aim of this study was to evaluate the analytical and clinical performance of a new commercial enzyme-linked immunosorbent assay (ELISA RSR, AQP4 Ab Version 2) to detect anti-AQP4 antibodies performed on a fully automated system (SkyLAB 752). METHODS: Serum samples from 64 patients with neuromyelitis optica spectrum disorders (NMOSD) (including NMO, longitudinally extensive myelitis-LETM, optical neuritis and myelitis) and 27 controls were tested for anti-AQP4 antibodies. All sera were previously tested using an indirect immunofluorescence (IIF) method on primate tissue, as the reference method. Commercial control sera were used to determine within-run, between-day and within-laboratory precision (CLSI guidelines). RESULTS: At a cut-off value of 2.1 U/mL as determined by ROC curves, sensitivity and specificity for NMO were 83.3% and 100%, respectively. The ELISA assay provided 100% concordant results with the reference IIF method. The median concentration of anti-AQP4 antibodies was statistically higher in patients with NMO than in patients with LETM (p = 0.0006) or with other NMOSD and in controls (p < 0.0001). At the concentration of 12.4 and 28.1 U/mL, the within-run, between-day and within-laboratory coefficients of variation (CV) were 3.2% and 3%, 7.6% and 7.4%, and 8.2% and 8.0%, respectively. CONCLUSIONS: This new ELISA method performed on a fully automated system, showed high sensitivity and absolute specificity, good CV in precision tests, and provided observer-independent quantitative results.