Cargando…

Enhanced contrast acoustic‐resolution photoacoustic microscopy using double‐stage delay‐multiply‐and‐sum beamformer for vasculature imaging

In acoustic‐resolution photoacoustic microscopy (AR‐PAM) systems, the lateral resolution in the focal zone of the ultrasound (US) transducer is determined by the numerical aperture (NA) of the transducer. To have a high lateral resolution, a large NA is used. However, the larger the NA, the smaller...

Descripción completa

Detalles Bibliográficos
Autores principales: Mozaffarzadeh, Moein, Varnosfaderani, Mehdi H. H., Sharma, Arunima, Pramanik, Manojit, de Jong, Nico, Verweij, Martin D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: WILEY‐VCH Verlag GmbH & Co. KGaA 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7065614/
https://www.ncbi.nlm.nih.gov/pubmed/31353839
http://dx.doi.org/10.1002/jbio.201900133
_version_ 1783505090489876480
author Mozaffarzadeh, Moein
Varnosfaderani, Mehdi H. H.
Sharma, Arunima
Pramanik, Manojit
de Jong, Nico
Verweij, Martin D.
author_facet Mozaffarzadeh, Moein
Varnosfaderani, Mehdi H. H.
Sharma, Arunima
Pramanik, Manojit
de Jong, Nico
Verweij, Martin D.
author_sort Mozaffarzadeh, Moein
collection PubMed
description In acoustic‐resolution photoacoustic microscopy (AR‐PAM) systems, the lateral resolution in the focal zone of the ultrasound (US) transducer is determined by the numerical aperture (NA) of the transducer. To have a high lateral resolution, a large NA is used. However, the larger the NA, the smaller the depth of focus [DOF]. As a result, the lateral resolution is deteriorated at depths out of the focal region. The synthetic aperture focusing technique (SAFT) along with a beamformer can be used to improve the resolution outside the focal region. In this work, for image formation in AR‐PAM, we propose the double‐stage delay‐multiply‐and‐sum (DS_DMAS) algorithm to be combined with SAFT. The proposed method is evaluated experimentally using hair targets and in vivo vasculature imaging. It is shown that DS_DMAS provides a higher resolution and contrast compared to other methods. For the B‐mode images obtained using the hair phantom, the proposed method reduces the average noise level for all the depths by about 134%, 57% and 23%, compared to the original low‐ resolution, SAFT+DAS and SAFT+DMAS methods, respectively. All the results indicate that the proposed method can be an appropriate algorithm for image formation in AR‐PAM systems. [Image: see text]
format Online
Article
Text
id pubmed-7065614
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher WILEY‐VCH Verlag GmbH & Co. KGaA
record_format MEDLINE/PubMed
spelling pubmed-70656142020-03-16 Enhanced contrast acoustic‐resolution photoacoustic microscopy using double‐stage delay‐multiply‐and‐sum beamformer for vasculature imaging Mozaffarzadeh, Moein Varnosfaderani, Mehdi H. H. Sharma, Arunima Pramanik, Manojit de Jong, Nico Verweij, Martin D. J Biophotonics Full Articles In acoustic‐resolution photoacoustic microscopy (AR‐PAM) systems, the lateral resolution in the focal zone of the ultrasound (US) transducer is determined by the numerical aperture (NA) of the transducer. To have a high lateral resolution, a large NA is used. However, the larger the NA, the smaller the depth of focus [DOF]. As a result, the lateral resolution is deteriorated at depths out of the focal region. The synthetic aperture focusing technique (SAFT) along with a beamformer can be used to improve the resolution outside the focal region. In this work, for image formation in AR‐PAM, we propose the double‐stage delay‐multiply‐and‐sum (DS_DMAS) algorithm to be combined with SAFT. The proposed method is evaluated experimentally using hair targets and in vivo vasculature imaging. It is shown that DS_DMAS provides a higher resolution and contrast compared to other methods. For the B‐mode images obtained using the hair phantom, the proposed method reduces the average noise level for all the depths by about 134%, 57% and 23%, compared to the original low‐ resolution, SAFT+DAS and SAFT+DMAS methods, respectively. All the results indicate that the proposed method can be an appropriate algorithm for image formation in AR‐PAM systems. [Image: see text] WILEY‐VCH Verlag GmbH & Co. KGaA 2019-08-07 2019-11 /pmc/articles/PMC7065614/ /pubmed/31353839 http://dx.doi.org/10.1002/jbio.201900133 Text en © 2019 The Authors. Journal of Biophotonics published by WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Full Articles
Mozaffarzadeh, Moein
Varnosfaderani, Mehdi H. H.
Sharma, Arunima
Pramanik, Manojit
de Jong, Nico
Verweij, Martin D.
Enhanced contrast acoustic‐resolution photoacoustic microscopy using double‐stage delay‐multiply‐and‐sum beamformer for vasculature imaging
title Enhanced contrast acoustic‐resolution photoacoustic microscopy using double‐stage delay‐multiply‐and‐sum beamformer for vasculature imaging
title_full Enhanced contrast acoustic‐resolution photoacoustic microscopy using double‐stage delay‐multiply‐and‐sum beamformer for vasculature imaging
title_fullStr Enhanced contrast acoustic‐resolution photoacoustic microscopy using double‐stage delay‐multiply‐and‐sum beamformer for vasculature imaging
title_full_unstemmed Enhanced contrast acoustic‐resolution photoacoustic microscopy using double‐stage delay‐multiply‐and‐sum beamformer for vasculature imaging
title_short Enhanced contrast acoustic‐resolution photoacoustic microscopy using double‐stage delay‐multiply‐and‐sum beamformer for vasculature imaging
title_sort enhanced contrast acoustic‐resolution photoacoustic microscopy using double‐stage delay‐multiply‐and‐sum beamformer for vasculature imaging
topic Full Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7065614/
https://www.ncbi.nlm.nih.gov/pubmed/31353839
http://dx.doi.org/10.1002/jbio.201900133
work_keys_str_mv AT mozaffarzadehmoein enhancedcontrastacousticresolutionphotoacousticmicroscopyusingdoublestagedelaymultiplyandsumbeamformerforvasculatureimaging
AT varnosfaderanimehdihh enhancedcontrastacousticresolutionphotoacousticmicroscopyusingdoublestagedelaymultiplyandsumbeamformerforvasculatureimaging
AT sharmaarunima enhancedcontrastacousticresolutionphotoacousticmicroscopyusingdoublestagedelaymultiplyandsumbeamformerforvasculatureimaging
AT pramanikmanojit enhancedcontrastacousticresolutionphotoacousticmicroscopyusingdoublestagedelaymultiplyandsumbeamformerforvasculatureimaging
AT dejongnico enhancedcontrastacousticresolutionphotoacousticmicroscopyusingdoublestagedelaymultiplyandsumbeamformerforvasculatureimaging
AT verweijmartind enhancedcontrastacousticresolutionphotoacousticmicroscopyusingdoublestagedelaymultiplyandsumbeamformerforvasculatureimaging