Cargando…
Enhanced contrast acoustic‐resolution photoacoustic microscopy using double‐stage delay‐multiply‐and‐sum beamformer for vasculature imaging
In acoustic‐resolution photoacoustic microscopy (AR‐PAM) systems, the lateral resolution in the focal zone of the ultrasound (US) transducer is determined by the numerical aperture (NA) of the transducer. To have a high lateral resolution, a large NA is used. However, the larger the NA, the smaller...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
WILEY‐VCH Verlag GmbH & Co. KGaA
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7065614/ https://www.ncbi.nlm.nih.gov/pubmed/31353839 http://dx.doi.org/10.1002/jbio.201900133 |
_version_ | 1783505090489876480 |
---|---|
author | Mozaffarzadeh, Moein Varnosfaderani, Mehdi H. H. Sharma, Arunima Pramanik, Manojit de Jong, Nico Verweij, Martin D. |
author_facet | Mozaffarzadeh, Moein Varnosfaderani, Mehdi H. H. Sharma, Arunima Pramanik, Manojit de Jong, Nico Verweij, Martin D. |
author_sort | Mozaffarzadeh, Moein |
collection | PubMed |
description | In acoustic‐resolution photoacoustic microscopy (AR‐PAM) systems, the lateral resolution in the focal zone of the ultrasound (US) transducer is determined by the numerical aperture (NA) of the transducer. To have a high lateral resolution, a large NA is used. However, the larger the NA, the smaller the depth of focus [DOF]. As a result, the lateral resolution is deteriorated at depths out of the focal region. The synthetic aperture focusing technique (SAFT) along with a beamformer can be used to improve the resolution outside the focal region. In this work, for image formation in AR‐PAM, we propose the double‐stage delay‐multiply‐and‐sum (DS_DMAS) algorithm to be combined with SAFT. The proposed method is evaluated experimentally using hair targets and in vivo vasculature imaging. It is shown that DS_DMAS provides a higher resolution and contrast compared to other methods. For the B‐mode images obtained using the hair phantom, the proposed method reduces the average noise level for all the depths by about 134%, 57% and 23%, compared to the original low‐ resolution, SAFT+DAS and SAFT+DMAS methods, respectively. All the results indicate that the proposed method can be an appropriate algorithm for image formation in AR‐PAM systems. [Image: see text] |
format | Online Article Text |
id | pubmed-7065614 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | WILEY‐VCH Verlag GmbH & Co. KGaA |
record_format | MEDLINE/PubMed |
spelling | pubmed-70656142020-03-16 Enhanced contrast acoustic‐resolution photoacoustic microscopy using double‐stage delay‐multiply‐and‐sum beamformer for vasculature imaging Mozaffarzadeh, Moein Varnosfaderani, Mehdi H. H. Sharma, Arunima Pramanik, Manojit de Jong, Nico Verweij, Martin D. J Biophotonics Full Articles In acoustic‐resolution photoacoustic microscopy (AR‐PAM) systems, the lateral resolution in the focal zone of the ultrasound (US) transducer is determined by the numerical aperture (NA) of the transducer. To have a high lateral resolution, a large NA is used. However, the larger the NA, the smaller the depth of focus [DOF]. As a result, the lateral resolution is deteriorated at depths out of the focal region. The synthetic aperture focusing technique (SAFT) along with a beamformer can be used to improve the resolution outside the focal region. In this work, for image formation in AR‐PAM, we propose the double‐stage delay‐multiply‐and‐sum (DS_DMAS) algorithm to be combined with SAFT. The proposed method is evaluated experimentally using hair targets and in vivo vasculature imaging. It is shown that DS_DMAS provides a higher resolution and contrast compared to other methods. For the B‐mode images obtained using the hair phantom, the proposed method reduces the average noise level for all the depths by about 134%, 57% and 23%, compared to the original low‐ resolution, SAFT+DAS and SAFT+DMAS methods, respectively. All the results indicate that the proposed method can be an appropriate algorithm for image formation in AR‐PAM systems. [Image: see text] WILEY‐VCH Verlag GmbH & Co. KGaA 2019-08-07 2019-11 /pmc/articles/PMC7065614/ /pubmed/31353839 http://dx.doi.org/10.1002/jbio.201900133 Text en © 2019 The Authors. Journal of Biophotonics published by WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Full Articles Mozaffarzadeh, Moein Varnosfaderani, Mehdi H. H. Sharma, Arunima Pramanik, Manojit de Jong, Nico Verweij, Martin D. Enhanced contrast acoustic‐resolution photoacoustic microscopy using double‐stage delay‐multiply‐and‐sum beamformer for vasculature imaging |
title | Enhanced contrast acoustic‐resolution photoacoustic microscopy using double‐stage delay‐multiply‐and‐sum beamformer for vasculature imaging |
title_full | Enhanced contrast acoustic‐resolution photoacoustic microscopy using double‐stage delay‐multiply‐and‐sum beamformer for vasculature imaging |
title_fullStr | Enhanced contrast acoustic‐resolution photoacoustic microscopy using double‐stage delay‐multiply‐and‐sum beamformer for vasculature imaging |
title_full_unstemmed | Enhanced contrast acoustic‐resolution photoacoustic microscopy using double‐stage delay‐multiply‐and‐sum beamformer for vasculature imaging |
title_short | Enhanced contrast acoustic‐resolution photoacoustic microscopy using double‐stage delay‐multiply‐and‐sum beamformer for vasculature imaging |
title_sort | enhanced contrast acoustic‐resolution photoacoustic microscopy using double‐stage delay‐multiply‐and‐sum beamformer for vasculature imaging |
topic | Full Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7065614/ https://www.ncbi.nlm.nih.gov/pubmed/31353839 http://dx.doi.org/10.1002/jbio.201900133 |
work_keys_str_mv | AT mozaffarzadehmoein enhancedcontrastacousticresolutionphotoacousticmicroscopyusingdoublestagedelaymultiplyandsumbeamformerforvasculatureimaging AT varnosfaderanimehdihh enhancedcontrastacousticresolutionphotoacousticmicroscopyusingdoublestagedelaymultiplyandsumbeamformerforvasculatureimaging AT sharmaarunima enhancedcontrastacousticresolutionphotoacousticmicroscopyusingdoublestagedelaymultiplyandsumbeamformerforvasculatureimaging AT pramanikmanojit enhancedcontrastacousticresolutionphotoacousticmicroscopyusingdoublestagedelaymultiplyandsumbeamformerforvasculatureimaging AT dejongnico enhancedcontrastacousticresolutionphotoacousticmicroscopyusingdoublestagedelaymultiplyandsumbeamformerforvasculatureimaging AT verweijmartind enhancedcontrastacousticresolutionphotoacousticmicroscopyusingdoublestagedelaymultiplyandsumbeamformerforvasculatureimaging |