Cargando…
A portable, low-cost device for precise control of specimen temperature under stereomicroscopes
To facilitate precise and convenient control of biological sample temperature, we developed a low-cost device that can be used independently or with any stereomicroscope. The purpose of the device is to control the thermal environment during experimental intervals in which a specimen must be manipul...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7065815/ https://www.ncbi.nlm.nih.gov/pubmed/32160236 http://dx.doi.org/10.1371/journal.pone.0230241 |
_version_ | 1783505127002341376 |
---|---|
author | Testa, Nicholas D. Kaul, Samiksha Le, Kim N. Zhan, Mei Lu, Hang Paaby, Annalise B. |
author_facet | Testa, Nicholas D. Kaul, Samiksha Le, Kim N. Zhan, Mei Lu, Hang Paaby, Annalise B. |
author_sort | Testa, Nicholas D. |
collection | PubMed |
description | To facilitate precise and convenient control of biological sample temperature, we developed a low-cost device that can be used independently or with any stereomicroscope. The purpose of the device is to control the thermal environment during experimental intervals in which a specimen must be manipulated outside of an incubator, e.g. for dissection or slide-mounting in preparation for imaging. Sample temperatures can be both cooled to below and heated to above room temperatures, and stably maintained at a precision of +/- 0.1˚C. To demonstrate the utility of this device, we report improved characterization of the penetrance of a short-acting temperature-sensitive allele in C. elegans embryos, and identification of the upper temperature threshold for embryonic viability for six Caenorhabditis species. By controlling the temperature environment even as a specimen is manipulated, this device offers consistency and flexibility, reduces environmental noise, and enables precision timing in experiments requiring temperature shifts. |
format | Online Article Text |
id | pubmed-7065815 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-70658152020-03-23 A portable, low-cost device for precise control of specimen temperature under stereomicroscopes Testa, Nicholas D. Kaul, Samiksha Le, Kim N. Zhan, Mei Lu, Hang Paaby, Annalise B. PLoS One Research Article To facilitate precise and convenient control of biological sample temperature, we developed a low-cost device that can be used independently or with any stereomicroscope. The purpose of the device is to control the thermal environment during experimental intervals in which a specimen must be manipulated outside of an incubator, e.g. for dissection or slide-mounting in preparation for imaging. Sample temperatures can be both cooled to below and heated to above room temperatures, and stably maintained at a precision of +/- 0.1˚C. To demonstrate the utility of this device, we report improved characterization of the penetrance of a short-acting temperature-sensitive allele in C. elegans embryos, and identification of the upper temperature threshold for embryonic viability for six Caenorhabditis species. By controlling the temperature environment even as a specimen is manipulated, this device offers consistency and flexibility, reduces environmental noise, and enables precision timing in experiments requiring temperature shifts. Public Library of Science 2020-03-11 /pmc/articles/PMC7065815/ /pubmed/32160236 http://dx.doi.org/10.1371/journal.pone.0230241 Text en © 2020 Testa et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Testa, Nicholas D. Kaul, Samiksha Le, Kim N. Zhan, Mei Lu, Hang Paaby, Annalise B. A portable, low-cost device for precise control of specimen temperature under stereomicroscopes |
title | A portable, low-cost device for precise control of specimen temperature under stereomicroscopes |
title_full | A portable, low-cost device for precise control of specimen temperature under stereomicroscopes |
title_fullStr | A portable, low-cost device for precise control of specimen temperature under stereomicroscopes |
title_full_unstemmed | A portable, low-cost device for precise control of specimen temperature under stereomicroscopes |
title_short | A portable, low-cost device for precise control of specimen temperature under stereomicroscopes |
title_sort | portable, low-cost device for precise control of specimen temperature under stereomicroscopes |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7065815/ https://www.ncbi.nlm.nih.gov/pubmed/32160236 http://dx.doi.org/10.1371/journal.pone.0230241 |
work_keys_str_mv | AT testanicholasd aportablelowcostdeviceforprecisecontrolofspecimentemperatureunderstereomicroscopes AT kaulsamiksha aportablelowcostdeviceforprecisecontrolofspecimentemperatureunderstereomicroscopes AT lekimn aportablelowcostdeviceforprecisecontrolofspecimentemperatureunderstereomicroscopes AT zhanmei aportablelowcostdeviceforprecisecontrolofspecimentemperatureunderstereomicroscopes AT luhang aportablelowcostdeviceforprecisecontrolofspecimentemperatureunderstereomicroscopes AT paabyannaliseb aportablelowcostdeviceforprecisecontrolofspecimentemperatureunderstereomicroscopes AT testanicholasd portablelowcostdeviceforprecisecontrolofspecimentemperatureunderstereomicroscopes AT kaulsamiksha portablelowcostdeviceforprecisecontrolofspecimentemperatureunderstereomicroscopes AT lekimn portablelowcostdeviceforprecisecontrolofspecimentemperatureunderstereomicroscopes AT zhanmei portablelowcostdeviceforprecisecontrolofspecimentemperatureunderstereomicroscopes AT luhang portablelowcostdeviceforprecisecontrolofspecimentemperatureunderstereomicroscopes AT paabyannaliseb portablelowcostdeviceforprecisecontrolofspecimentemperatureunderstereomicroscopes |