Cargando…
Comparison of Quantitative light-induced fluorescence-digital (QLF-D) images and images of disclosed plaque for planimetric quantification of dental plaque in multibracket appliance patients
The purpose of the present cross-sectional clinical study was to check the ability of plaque detection and quantification by QLF-D against conventional digital photographs of disclosed plaque in multibracket appliance (MB) patients. 20 patients were included according to the following criteria: (1)...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7066241/ https://www.ncbi.nlm.nih.gov/pubmed/32161288 http://dx.doi.org/10.1038/s41598-020-61454-9 |
_version_ | 1783505207542415360 |
---|---|
author | Klaus, Katharina Glanz, Tabea Glanz, Alexander Georg Ganss, Carolina Ruf, Sabine |
author_facet | Klaus, Katharina Glanz, Tabea Glanz, Alexander Georg Ganss, Carolina Ruf, Sabine |
author_sort | Klaus, Katharina |
collection | PubMed |
description | The purpose of the present cross-sectional clinical study was to check the ability of plaque detection and quantification by QLF-D against conventional digital photographs of disclosed plaque in multibracket appliance (MB) patients. 20 patients were included according to the following criteria: (1) upper and lower jaw treated by MB appliance, (2) patients being 16 years of age or older, (3) all central and lateral incisors as well as canines in situ, (4) absence of developmental defects, carious lesions, surface fillings, prosthetic restorations or recessions greater than 1/3 of root length in central/lateral incisors and canines as well as (5) declaration of consent. QLF-D and conventional photographs were analyzed planimetrically regarding plaque coverage on buccal and oral surfaces of central/lateral incisors and canines. The conventional photographs of stained plaque served as gold standard. On average, in QLF-D pictures 20.7% ± 17.4 of the tooth surfaces were covered with plaque, while the conventional photographs of disclosed plaque presented a mean plaque-covered area of 36.2% ± 23.5. The Bland-Altman plot for both imaging modalities showed a very large inconsistent scattering with both negative and positive deviations. The method discrepancy increased with increasing plaque coverage, thus indicating a systematic method error. On average, the deviation of the methods from the optimal line of accordance was −15.5%. In patients wearing MB appliances, there was no clinical significant agreement regarding the plaque-covered tooth surface depicted by QLF-D respectively conventional images of disclosed plaque. Due to the large method discrepancy, QLF-D is currently not reliable for precise plaque quantification in MB patients. |
format | Online Article Text |
id | pubmed-7066241 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-70662412020-03-19 Comparison of Quantitative light-induced fluorescence-digital (QLF-D) images and images of disclosed plaque for planimetric quantification of dental plaque in multibracket appliance patients Klaus, Katharina Glanz, Tabea Glanz, Alexander Georg Ganss, Carolina Ruf, Sabine Sci Rep Article The purpose of the present cross-sectional clinical study was to check the ability of plaque detection and quantification by QLF-D against conventional digital photographs of disclosed plaque in multibracket appliance (MB) patients. 20 patients were included according to the following criteria: (1) upper and lower jaw treated by MB appliance, (2) patients being 16 years of age or older, (3) all central and lateral incisors as well as canines in situ, (4) absence of developmental defects, carious lesions, surface fillings, prosthetic restorations or recessions greater than 1/3 of root length in central/lateral incisors and canines as well as (5) declaration of consent. QLF-D and conventional photographs were analyzed planimetrically regarding plaque coverage on buccal and oral surfaces of central/lateral incisors and canines. The conventional photographs of stained plaque served as gold standard. On average, in QLF-D pictures 20.7% ± 17.4 of the tooth surfaces were covered with plaque, while the conventional photographs of disclosed plaque presented a mean plaque-covered area of 36.2% ± 23.5. The Bland-Altman plot for both imaging modalities showed a very large inconsistent scattering with both negative and positive deviations. The method discrepancy increased with increasing plaque coverage, thus indicating a systematic method error. On average, the deviation of the methods from the optimal line of accordance was −15.5%. In patients wearing MB appliances, there was no clinical significant agreement regarding the plaque-covered tooth surface depicted by QLF-D respectively conventional images of disclosed plaque. Due to the large method discrepancy, QLF-D is currently not reliable for precise plaque quantification in MB patients. Nature Publishing Group UK 2020-03-11 /pmc/articles/PMC7066241/ /pubmed/32161288 http://dx.doi.org/10.1038/s41598-020-61454-9 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Klaus, Katharina Glanz, Tabea Glanz, Alexander Georg Ganss, Carolina Ruf, Sabine Comparison of Quantitative light-induced fluorescence-digital (QLF-D) images and images of disclosed plaque for planimetric quantification of dental plaque in multibracket appliance patients |
title | Comparison of Quantitative light-induced fluorescence-digital (QLF-D) images and images of disclosed plaque for planimetric quantification of dental plaque in multibracket appliance patients |
title_full | Comparison of Quantitative light-induced fluorescence-digital (QLF-D) images and images of disclosed plaque for planimetric quantification of dental plaque in multibracket appliance patients |
title_fullStr | Comparison of Quantitative light-induced fluorescence-digital (QLF-D) images and images of disclosed plaque for planimetric quantification of dental plaque in multibracket appliance patients |
title_full_unstemmed | Comparison of Quantitative light-induced fluorescence-digital (QLF-D) images and images of disclosed plaque for planimetric quantification of dental plaque in multibracket appliance patients |
title_short | Comparison of Quantitative light-induced fluorescence-digital (QLF-D) images and images of disclosed plaque for planimetric quantification of dental plaque in multibracket appliance patients |
title_sort | comparison of quantitative light-induced fluorescence-digital (qlf-d) images and images of disclosed plaque for planimetric quantification of dental plaque in multibracket appliance patients |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7066241/ https://www.ncbi.nlm.nih.gov/pubmed/32161288 http://dx.doi.org/10.1038/s41598-020-61454-9 |
work_keys_str_mv | AT klauskatharina comparisonofquantitativelightinducedfluorescencedigitalqlfdimagesandimagesofdisclosedplaqueforplanimetricquantificationofdentalplaqueinmultibracketappliancepatients AT glanztabea comparisonofquantitativelightinducedfluorescencedigitalqlfdimagesandimagesofdisclosedplaqueforplanimetricquantificationofdentalplaqueinmultibracketappliancepatients AT glanzalexandergeorg comparisonofquantitativelightinducedfluorescencedigitalqlfdimagesandimagesofdisclosedplaqueforplanimetricquantificationofdentalplaqueinmultibracketappliancepatients AT gansscarolina comparisonofquantitativelightinducedfluorescencedigitalqlfdimagesandimagesofdisclosedplaqueforplanimetricquantificationofdentalplaqueinmultibracketappliancepatients AT rufsabine comparisonofquantitativelightinducedfluorescencedigitalqlfdimagesandimagesofdisclosedplaqueforplanimetricquantificationofdentalplaqueinmultibracketappliancepatients |