Cargando…

Reliability and reproducibility of the new AO/OTA 2018 classification system for proximal humeral fractures: a comparison of three different classification systems

BACKGROUND: The classification systems for proximal humeral fractures routinely used in clinical practice include the Neer and Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association (AO/OTA) 2007 systems. Currently used systems have low inter- and intraobserver reliability. In 20...

Descripción completa

Detalles Bibliográficos
Autores principales: Marongiu, Giuseppe, Leinardi, Lorenzo, Congia, Stefano, Frigau, Luca, Mola, Francesco, Capone, Antonio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7067934/
https://www.ncbi.nlm.nih.gov/pubmed/32166457
http://dx.doi.org/10.1186/s10195-020-0543-1
_version_ 1783505487342338048
author Marongiu, Giuseppe
Leinardi, Lorenzo
Congia, Stefano
Frigau, Luca
Mola, Francesco
Capone, Antonio
author_facet Marongiu, Giuseppe
Leinardi, Lorenzo
Congia, Stefano
Frigau, Luca
Mola, Francesco
Capone, Antonio
author_sort Marongiu, Giuseppe
collection PubMed
description BACKGROUND: The classification systems for proximal humeral fractures routinely used in clinical practice include the Neer and Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association (AO/OTA) 2007 systems. Currently used systems have low inter- and intraobserver reliability. In 2018, AO/OTA introduced a new classification system with the aim of simplifying the coding process, in which the Neer four-part classification was integrated into the fracture description. The aim of the present work is to assess the inter- and intraobserver agreement of the new AO/OTA 2018 compared with the Neer and AO/OTA 2007 classifications. MATERIALS AND METHODS: A total of 116 radiographs of consecutive patients with proximal humeral fracture were selected and classified by three observers with different levels of experience. All three observers independently reviewed and classified the images according to the Neer, AO/OTA 2007, and new AO/OTA 2018 systems. To determine the intraobserver agreement, the observers reviewed the same set of radiographs after an interval of 8 weeks. The inter- and intraobserver agreement were determined through Cohen’s kappa coefficient analysis. RESULTS: The new AO/OTA 2018 classification showed substantial mean inter- (k = 0.67) and intraobserver (k = 0.75) agreement. These results are similar to the reliability observed for the Neer classification (interobserver, k = 0.67; intraobserver, k = 0.85) but better than those found for the AO/OTA 2007 system, which showed only moderate inter- (k = 0.57) and intraobserver (k = 0.58) agreement. The two more experienced observers showed better overall agreement, but no statistically significant difference was found. No differences were found between surgical experience and agreement regarding specific fracture types or groups. CONCLUSIONS: The results showed that the Neer system still represents the more reliable and reproducible classification. However, the new AO/OTA 2018 classification improved the agreement among observers compared with the AO/OTA 2007 system, while still maintaining substantial descriptive power and simplifying the coding process. The universal modifiers and qualifications, despite their possible complexity, allowed a more comprehensive fracture definition without negatively affecting the reliability or reproducibility of the classification system. Level of evidence: Level III, diagnostic studies
format Online
Article
Text
id pubmed-7067934
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-70679342020-03-23 Reliability and reproducibility of the new AO/OTA 2018 classification system for proximal humeral fractures: a comparison of three different classification systems Marongiu, Giuseppe Leinardi, Lorenzo Congia, Stefano Frigau, Luca Mola, Francesco Capone, Antonio J Orthop Traumatol Original Article BACKGROUND: The classification systems for proximal humeral fractures routinely used in clinical practice include the Neer and Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association (AO/OTA) 2007 systems. Currently used systems have low inter- and intraobserver reliability. In 2018, AO/OTA introduced a new classification system with the aim of simplifying the coding process, in which the Neer four-part classification was integrated into the fracture description. The aim of the present work is to assess the inter- and intraobserver agreement of the new AO/OTA 2018 compared with the Neer and AO/OTA 2007 classifications. MATERIALS AND METHODS: A total of 116 radiographs of consecutive patients with proximal humeral fracture were selected and classified by three observers with different levels of experience. All three observers independently reviewed and classified the images according to the Neer, AO/OTA 2007, and new AO/OTA 2018 systems. To determine the intraobserver agreement, the observers reviewed the same set of radiographs after an interval of 8 weeks. The inter- and intraobserver agreement were determined through Cohen’s kappa coefficient analysis. RESULTS: The new AO/OTA 2018 classification showed substantial mean inter- (k = 0.67) and intraobserver (k = 0.75) agreement. These results are similar to the reliability observed for the Neer classification (interobserver, k = 0.67; intraobserver, k = 0.85) but better than those found for the AO/OTA 2007 system, which showed only moderate inter- (k = 0.57) and intraobserver (k = 0.58) agreement. The two more experienced observers showed better overall agreement, but no statistically significant difference was found. No differences were found between surgical experience and agreement regarding specific fracture types or groups. CONCLUSIONS: The results showed that the Neer system still represents the more reliable and reproducible classification. However, the new AO/OTA 2018 classification improved the agreement among observers compared with the AO/OTA 2007 system, while still maintaining substantial descriptive power and simplifying the coding process. The universal modifiers and qualifications, despite their possible complexity, allowed a more comprehensive fracture definition without negatively affecting the reliability or reproducibility of the classification system. Level of evidence: Level III, diagnostic studies Springer International Publishing 2020-03-12 2020-12 /pmc/articles/PMC7067934/ /pubmed/32166457 http://dx.doi.org/10.1186/s10195-020-0543-1 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Original Article
Marongiu, Giuseppe
Leinardi, Lorenzo
Congia, Stefano
Frigau, Luca
Mola, Francesco
Capone, Antonio
Reliability and reproducibility of the new AO/OTA 2018 classification system for proximal humeral fractures: a comparison of three different classification systems
title Reliability and reproducibility of the new AO/OTA 2018 classification system for proximal humeral fractures: a comparison of three different classification systems
title_full Reliability and reproducibility of the new AO/OTA 2018 classification system for proximal humeral fractures: a comparison of three different classification systems
title_fullStr Reliability and reproducibility of the new AO/OTA 2018 classification system for proximal humeral fractures: a comparison of three different classification systems
title_full_unstemmed Reliability and reproducibility of the new AO/OTA 2018 classification system for proximal humeral fractures: a comparison of three different classification systems
title_short Reliability and reproducibility of the new AO/OTA 2018 classification system for proximal humeral fractures: a comparison of three different classification systems
title_sort reliability and reproducibility of the new ao/ota 2018 classification system for proximal humeral fractures: a comparison of three different classification systems
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7067934/
https://www.ncbi.nlm.nih.gov/pubmed/32166457
http://dx.doi.org/10.1186/s10195-020-0543-1
work_keys_str_mv AT marongiugiuseppe reliabilityandreproducibilityofthenewaoota2018classificationsystemforproximalhumeralfracturesacomparisonofthreedifferentclassificationsystems
AT leinardilorenzo reliabilityandreproducibilityofthenewaoota2018classificationsystemforproximalhumeralfracturesacomparisonofthreedifferentclassificationsystems
AT congiastefano reliabilityandreproducibilityofthenewaoota2018classificationsystemforproximalhumeralfracturesacomparisonofthreedifferentclassificationsystems
AT frigauluca reliabilityandreproducibilityofthenewaoota2018classificationsystemforproximalhumeralfracturesacomparisonofthreedifferentclassificationsystems
AT molafrancesco reliabilityandreproducibilityofthenewaoota2018classificationsystemforproximalhumeralfracturesacomparisonofthreedifferentclassificationsystems
AT caponeantonio reliabilityandreproducibilityofthenewaoota2018classificationsystemforproximalhumeralfracturesacomparisonofthreedifferentclassificationsystems