An optimization method for implantation parameters of individualized TKA tibial prosthesis based on finite element analysis and orthogonal experimental design

BACKGROUND: Individualized and accurate implantation of a tibial prosthesis during total knee arthroplasty (TKA) can assist in uniformly distributing the load and reducing the polyethylene wear to obtain a long-term prosthetic survival rate, but individualized and accurate implantation of a tibial p...

Descripción completa

Detalles Bibliográficos
Autores principales: Dong, Yuefu, Zhang, Zhen, Dong, Wanpeng, Hu, Guanghong, Wang, Bing, Mou, Zhifang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7068904/
https://www.ncbi.nlm.nih.gov/pubmed/32164625
http://dx.doi.org/10.1186/s12891-020-3189-5
_version_ 1783505668004642816
author Dong, Yuefu
Zhang, Zhen
Dong, Wanpeng
Hu, Guanghong
Wang, Bing
Mou, Zhifang
author_facet Dong, Yuefu
Zhang, Zhen
Dong, Wanpeng
Hu, Guanghong
Wang, Bing
Mou, Zhifang
author_sort Dong, Yuefu
collection PubMed
description BACKGROUND: Individualized and accurate implantation of a tibial prosthesis during total knee arthroplasty (TKA) can assist in uniformly distributing the load and reducing the polyethylene wear to obtain a long-term prosthetic survival rate, but individualized and accurate implantation of a tibial prosthesis during TKA remains challenging. The purpose of this study was to optimize and individualize the positioning parameters of a tibial prosthesis to improve its accurate implantation using a new method of finite element analysis in combination with orthogonal experimental design. METHODS: Ten finite element models of TKA knee joint were developed to optimize the implantation parameters (varus angle, posterior slope angle, and external rotation angle) of tibial prosthesis to reduce the peak value of the contact pressure on the polyethylene liner according to the method of finite element analysis in combination with orthogonal experimental design. The influence of implantation parameters on the peak value of the contact pressure on the polyethylene liner was evaluated based on a range analysis in orthogonal experimental design. RESULTS: The optimal implantation parameters for tibial prosthesis included 0° varus, 1° posterior slope, and 4° external rotation. Under these conditions, the peak value of the contact pressure on the polyethylene liner remained the smallest (16.37 MPa). Among the three parameters that affect the peak value of the contact pressure, the varus angle had the greatest effect (range = 6.70), followed by the posterior slope angle (range = 2.36), and the external rotation angle (range = 2.15). CONCLUSIONS: The optimization method based on finite element analysis and orthogonal experimental design can guide the accurate implantation of the tibial prosthesis, reducing the peak value of the contact pressure on the polyethylene liner. This method provides new insights into the TKA preoperative plan and biomechanical decision-making for accurately implanting TKA prosthesis.
format Online
Article
Text
id pubmed-7068904
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-70689042020-03-18 An optimization method for implantation parameters of individualized TKA tibial prosthesis based on finite element analysis and orthogonal experimental design Dong, Yuefu Zhang, Zhen Dong, Wanpeng Hu, Guanghong Wang, Bing Mou, Zhifang BMC Musculoskelet Disord Research Article BACKGROUND: Individualized and accurate implantation of a tibial prosthesis during total knee arthroplasty (TKA) can assist in uniformly distributing the load and reducing the polyethylene wear to obtain a long-term prosthetic survival rate, but individualized and accurate implantation of a tibial prosthesis during TKA remains challenging. The purpose of this study was to optimize and individualize the positioning parameters of a tibial prosthesis to improve its accurate implantation using a new method of finite element analysis in combination with orthogonal experimental design. METHODS: Ten finite element models of TKA knee joint were developed to optimize the implantation parameters (varus angle, posterior slope angle, and external rotation angle) of tibial prosthesis to reduce the peak value of the contact pressure on the polyethylene liner according to the method of finite element analysis in combination with orthogonal experimental design. The influence of implantation parameters on the peak value of the contact pressure on the polyethylene liner was evaluated based on a range analysis in orthogonal experimental design. RESULTS: The optimal implantation parameters for tibial prosthesis included 0° varus, 1° posterior slope, and 4° external rotation. Under these conditions, the peak value of the contact pressure on the polyethylene liner remained the smallest (16.37 MPa). Among the three parameters that affect the peak value of the contact pressure, the varus angle had the greatest effect (range = 6.70), followed by the posterior slope angle (range = 2.36), and the external rotation angle (range = 2.15). CONCLUSIONS: The optimization method based on finite element analysis and orthogonal experimental design can guide the accurate implantation of the tibial prosthesis, reducing the peak value of the contact pressure on the polyethylene liner. This method provides new insights into the TKA preoperative plan and biomechanical decision-making for accurately implanting TKA prosthesis. BioMed Central 2020-03-12 /pmc/articles/PMC7068904/ /pubmed/32164625 http://dx.doi.org/10.1186/s12891-020-3189-5 Text en © The Author(s). 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Dong, Yuefu
Zhang, Zhen
Dong, Wanpeng
Hu, Guanghong
Wang, Bing
Mou, Zhifang
An optimization method for implantation parameters of individualized TKA tibial prosthesis based on finite element analysis and orthogonal experimental design
title An optimization method for implantation parameters of individualized TKA tibial prosthesis based on finite element analysis and orthogonal experimental design
title_full An optimization method for implantation parameters of individualized TKA tibial prosthesis based on finite element analysis and orthogonal experimental design
title_fullStr An optimization method for implantation parameters of individualized TKA tibial prosthesis based on finite element analysis and orthogonal experimental design
title_full_unstemmed An optimization method for implantation parameters of individualized TKA tibial prosthesis based on finite element analysis and orthogonal experimental design
title_short An optimization method for implantation parameters of individualized TKA tibial prosthesis based on finite element analysis and orthogonal experimental design
title_sort optimization method for implantation parameters of individualized tka tibial prosthesis based on finite element analysis and orthogonal experimental design
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7068904/
https://www.ncbi.nlm.nih.gov/pubmed/32164625
http://dx.doi.org/10.1186/s12891-020-3189-5
work_keys_str_mv AT dongyuefu anoptimizationmethodforimplantationparametersofindividualizedtkatibialprosthesisbasedonfiniteelementanalysisandorthogonalexperimentaldesign
AT zhangzhen anoptimizationmethodforimplantationparametersofindividualizedtkatibialprosthesisbasedonfiniteelementanalysisandorthogonalexperimentaldesign
AT dongwanpeng anoptimizationmethodforimplantationparametersofindividualizedtkatibialprosthesisbasedonfiniteelementanalysisandorthogonalexperimentaldesign
AT huguanghong anoptimizationmethodforimplantationparametersofindividualizedtkatibialprosthesisbasedonfiniteelementanalysisandorthogonalexperimentaldesign
AT wangbing anoptimizationmethodforimplantationparametersofindividualizedtkatibialprosthesisbasedonfiniteelementanalysisandorthogonalexperimentaldesign
AT mouzhifang anoptimizationmethodforimplantationparametersofindividualizedtkatibialprosthesisbasedonfiniteelementanalysisandorthogonalexperimentaldesign
AT dongyuefu optimizationmethodforimplantationparametersofindividualizedtkatibialprosthesisbasedonfiniteelementanalysisandorthogonalexperimentaldesign
AT zhangzhen optimizationmethodforimplantationparametersofindividualizedtkatibialprosthesisbasedonfiniteelementanalysisandorthogonalexperimentaldesign
AT dongwanpeng optimizationmethodforimplantationparametersofindividualizedtkatibialprosthesisbasedonfiniteelementanalysisandorthogonalexperimentaldesign
AT huguanghong optimizationmethodforimplantationparametersofindividualizedtkatibialprosthesisbasedonfiniteelementanalysisandorthogonalexperimentaldesign
AT wangbing optimizationmethodforimplantationparametersofindividualizedtkatibialprosthesisbasedonfiniteelementanalysisandorthogonalexperimentaldesign
AT mouzhifang optimizationmethodforimplantationparametersofindividualizedtkatibialprosthesisbasedonfiniteelementanalysisandorthogonalexperimentaldesign