Cargando…
Extrahepatic cholangiography in near-infrared II window with the clinically approved fluorescence agent indocyanine green: a promising imaging technology for intraoperative diagnosis
Rationale: Biliary tract injury remains the most dreaded complication during laparoscopic cholecystectomy. New intraoperative guidance technologies, including near-infrared (NIR) fluorescence cholangiography with indocyanine green (ICG), are under comprehensive evaluation. Previous studies had shown...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Ivyspring International Publisher
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7069080/ https://www.ncbi.nlm.nih.gov/pubmed/32206113 http://dx.doi.org/10.7150/thno.41127 |
_version_ | 1783505707613552640 |
---|---|
author | Wu, Di Xue, Dingwei Zhou, Jing Wang, Yifan Feng, Zhe Xu, Junjie Lin, Hui Qian, Jun Cai, Xiujun |
author_facet | Wu, Di Xue, Dingwei Zhou, Jing Wang, Yifan Feng, Zhe Xu, Junjie Lin, Hui Qian, Jun Cai, Xiujun |
author_sort | Wu, Di |
collection | PubMed |
description | Rationale: Biliary tract injury remains the most dreaded complication during laparoscopic cholecystectomy. New intraoperative guidance technologies, including near-infrared (NIR) fluorescence cholangiography with indocyanine green (ICG), are under comprehensive evaluation. Previous studies had shown the limitations of traditional NIR light (NIR-I, 700-900 nm) in visualizing the biliary tract structures in specific clinical situations. The aim of this study was to evaluate the feasibility of performing the extrahepatic cholangiography in the second NIR window (NIR-II, 900-1700 nm) and compare it to the conventional NIR-I imaging. Methods: The absorption and emission spectra, as well as fluorescence intensity and photostability of ICG-bile solution in the NIR-II window were recorded and measured. In vitro intralipid(®) phantom imaging was performed to evaluate tissue penetrating depth in NIR-I and NIR-II window. Different clinical scenarios were modeled by broadening the penetration distance or generating bile duct injuries, and bile duct visualization and lesion site diagnosis in the NIR-II window were evaluated and compared with NIR-I imaging. Results: The fluorescence spectrum of ICG-bile solution extends well into the NIR-II region, exhibiting intense emission value and excellent photostability sufficient for NIR-II biliary tract imaging. Extrahepatic cholangiography using ICG in the NIR-II window obviously reduced background signal and enhanced penetration depth, providing more structural information and improved visualization of the bile duct or lesion location in simulated clinical scenarios, outperforming the NIR-I window imaging. Conclusions: The conventional clinically approved agent ICG is an excellent fluorophore for NIR-II bile duct imaging. Fluorescence cholangiography with ICG in the NIR-II window could provide adequate visualization of the biliary tract structures with increased resolution and penetration depth and might be a valid option to increase the safety of cholecystectomy in difficult cases. |
format | Online Article Text |
id | pubmed-7069080 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Ivyspring International Publisher |
record_format | MEDLINE/PubMed |
spelling | pubmed-70690802020-03-23 Extrahepatic cholangiography in near-infrared II window with the clinically approved fluorescence agent indocyanine green: a promising imaging technology for intraoperative diagnosis Wu, Di Xue, Dingwei Zhou, Jing Wang, Yifan Feng, Zhe Xu, Junjie Lin, Hui Qian, Jun Cai, Xiujun Theranostics Research Paper Rationale: Biliary tract injury remains the most dreaded complication during laparoscopic cholecystectomy. New intraoperative guidance technologies, including near-infrared (NIR) fluorescence cholangiography with indocyanine green (ICG), are under comprehensive evaluation. Previous studies had shown the limitations of traditional NIR light (NIR-I, 700-900 nm) in visualizing the biliary tract structures in specific clinical situations. The aim of this study was to evaluate the feasibility of performing the extrahepatic cholangiography in the second NIR window (NIR-II, 900-1700 nm) and compare it to the conventional NIR-I imaging. Methods: The absorption and emission spectra, as well as fluorescence intensity and photostability of ICG-bile solution in the NIR-II window were recorded and measured. In vitro intralipid(®) phantom imaging was performed to evaluate tissue penetrating depth in NIR-I and NIR-II window. Different clinical scenarios were modeled by broadening the penetration distance or generating bile duct injuries, and bile duct visualization and lesion site diagnosis in the NIR-II window were evaluated and compared with NIR-I imaging. Results: The fluorescence spectrum of ICG-bile solution extends well into the NIR-II region, exhibiting intense emission value and excellent photostability sufficient for NIR-II biliary tract imaging. Extrahepatic cholangiography using ICG in the NIR-II window obviously reduced background signal and enhanced penetration depth, providing more structural information and improved visualization of the bile duct or lesion location in simulated clinical scenarios, outperforming the NIR-I window imaging. Conclusions: The conventional clinically approved agent ICG is an excellent fluorophore for NIR-II bile duct imaging. Fluorescence cholangiography with ICG in the NIR-II window could provide adequate visualization of the biliary tract structures with increased resolution and penetration depth and might be a valid option to increase the safety of cholecystectomy in difficult cases. Ivyspring International Publisher 2020-02-19 /pmc/articles/PMC7069080/ /pubmed/32206113 http://dx.doi.org/10.7150/thno.41127 Text en © The author(s) This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/). See http://ivyspring.com/terms for full terms and conditions. |
spellingShingle | Research Paper Wu, Di Xue, Dingwei Zhou, Jing Wang, Yifan Feng, Zhe Xu, Junjie Lin, Hui Qian, Jun Cai, Xiujun Extrahepatic cholangiography in near-infrared II window with the clinically approved fluorescence agent indocyanine green: a promising imaging technology for intraoperative diagnosis |
title | Extrahepatic cholangiography in near-infrared II window with the clinically approved fluorescence agent indocyanine green: a promising imaging technology for intraoperative diagnosis |
title_full | Extrahepatic cholangiography in near-infrared II window with the clinically approved fluorescence agent indocyanine green: a promising imaging technology for intraoperative diagnosis |
title_fullStr | Extrahepatic cholangiography in near-infrared II window with the clinically approved fluorescence agent indocyanine green: a promising imaging technology for intraoperative diagnosis |
title_full_unstemmed | Extrahepatic cholangiography in near-infrared II window with the clinically approved fluorescence agent indocyanine green: a promising imaging technology for intraoperative diagnosis |
title_short | Extrahepatic cholangiography in near-infrared II window with the clinically approved fluorescence agent indocyanine green: a promising imaging technology for intraoperative diagnosis |
title_sort | extrahepatic cholangiography in near-infrared ii window with the clinically approved fluorescence agent indocyanine green: a promising imaging technology for intraoperative diagnosis |
topic | Research Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7069080/ https://www.ncbi.nlm.nih.gov/pubmed/32206113 http://dx.doi.org/10.7150/thno.41127 |
work_keys_str_mv | AT wudi extrahepaticcholangiographyinnearinfrarediiwindowwiththeclinicallyapprovedfluorescenceagentindocyaninegreenapromisingimagingtechnologyforintraoperativediagnosis AT xuedingwei extrahepaticcholangiographyinnearinfrarediiwindowwiththeclinicallyapprovedfluorescenceagentindocyaninegreenapromisingimagingtechnologyforintraoperativediagnosis AT zhoujing extrahepaticcholangiographyinnearinfrarediiwindowwiththeclinicallyapprovedfluorescenceagentindocyaninegreenapromisingimagingtechnologyforintraoperativediagnosis AT wangyifan extrahepaticcholangiographyinnearinfrarediiwindowwiththeclinicallyapprovedfluorescenceagentindocyaninegreenapromisingimagingtechnologyforintraoperativediagnosis AT fengzhe extrahepaticcholangiographyinnearinfrarediiwindowwiththeclinicallyapprovedfluorescenceagentindocyaninegreenapromisingimagingtechnologyforintraoperativediagnosis AT xujunjie extrahepaticcholangiographyinnearinfrarediiwindowwiththeclinicallyapprovedfluorescenceagentindocyaninegreenapromisingimagingtechnologyforintraoperativediagnosis AT linhui extrahepaticcholangiographyinnearinfrarediiwindowwiththeclinicallyapprovedfluorescenceagentindocyaninegreenapromisingimagingtechnologyforintraoperativediagnosis AT qianjun extrahepaticcholangiographyinnearinfrarediiwindowwiththeclinicallyapprovedfluorescenceagentindocyaninegreenapromisingimagingtechnologyforintraoperativediagnosis AT caixiujun extrahepaticcholangiographyinnearinfrarediiwindowwiththeclinicallyapprovedfluorescenceagentindocyaninegreenapromisingimagingtechnologyforintraoperativediagnosis |