Cargando…
Diagnostic accuracy and utility of three dengue diagnostic tests for the diagnosis of acute dengue infection in Malaysia
BACKGROUND: Dengue is an emerging infectious disease that infects up to 390 million people yearly. The growing demand of dengue diagnostics especially in low-resource settings gave rise to many rapid diagnostic tests (RDT). This study evaluated the accuracy and utility of ViroTrack Dengue Acute - a...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7069157/ https://www.ncbi.nlm.nih.gov/pubmed/32164538 http://dx.doi.org/10.1186/s12879-020-4911-5 |
_version_ | 1783505724696952832 |
---|---|
author | Chong, Zhuo Lin Sekaran, Shamala Devi Soe, Hui Jen Peramalah, Devi Rampal, Sanjay Ng, Chiu-Wan |
author_facet | Chong, Zhuo Lin Sekaran, Shamala Devi Soe, Hui Jen Peramalah, Devi Rampal, Sanjay Ng, Chiu-Wan |
author_sort | Chong, Zhuo Lin |
collection | PubMed |
description | BACKGROUND: Dengue is an emerging infectious disease that infects up to 390 million people yearly. The growing demand of dengue diagnostics especially in low-resource settings gave rise to many rapid diagnostic tests (RDT). This study evaluated the accuracy and utility of ViroTrack Dengue Acute - a new biosensors-based dengue NS1 RDT, SD Bioline Dengue Duo NS1/IgM/IgG combo - a commercially available RDT, and SD Dengue NS1 Ag enzyme-linked immunosorbent assay (ELISA), for the diagnosis of acute dengue infection. METHODS: This prospective cross-sectional study consecutively recruited 494 patients with suspected dengue from a health clinic in Malaysia. Both RDTs were performed onsite. The evaluated ELISA and reference tests were performed in a virology laboratory. The reference tests comprised of a reverse transcription-polymerase chain reaction and three ELISAs for the detection of dengue NS1 antigen, IgM and IgG antibodies, respectively. The diagnostic performance of evaluated tests was computed using STATA version 12. RESULTS: The sensitivity and specificity of ViroTrack were 62.3% (95%CI 55.6–68.7) and 95.0% (95%CI 91.7–97.3), versus 66.5% (95%CI 60.0–72.6) and 95.4% (95%CI 92.1–97.6) for SD NS1 ELISA, and 52.4% (95%CI 45.7–59.1) and 97.7% (95%CI 95.1–99.2) for NS1 component of SD Bioline, respectively. The combination of the latter with its IgM and IgG components were able to increase test sensitivity to 82.4% (95%CI 76.8–87.1) with corresponding decrease in specificity to 87.4% (95%CI 82.8–91.2). Although a positive test on any of the NS1 assays would increase the probability of dengue to above 90% in a patient, a negative result would only reduce this probability to 23.0–29.3%. In contrast, this probability of false negative diagnosis would be further reduced to 14.7% (95%CI 11.4–18.6) if SD Bioline NS1/IgM/IgG combo was negative. CONCLUSIONS: The performance of ViroTrack Dengue Acute was comparable to SD Dengue NS1 Ag ELISA. Addition of serology components to SD Bioline Dengue Duo significantly improved its sensitivity and reduced its false negative rate such that it missed the fewest dengue patients, making it a better point-of-care diagnostic tool. New RDT like ViroTrack Dengue Acute may be a potential alternative to existing RDT if its combination with serology components is proven better in future studies. |
format | Online Article Text |
id | pubmed-7069157 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-70691572020-03-18 Diagnostic accuracy and utility of three dengue diagnostic tests for the diagnosis of acute dengue infection in Malaysia Chong, Zhuo Lin Sekaran, Shamala Devi Soe, Hui Jen Peramalah, Devi Rampal, Sanjay Ng, Chiu-Wan BMC Infect Dis Research Article BACKGROUND: Dengue is an emerging infectious disease that infects up to 390 million people yearly. The growing demand of dengue diagnostics especially in low-resource settings gave rise to many rapid diagnostic tests (RDT). This study evaluated the accuracy and utility of ViroTrack Dengue Acute - a new biosensors-based dengue NS1 RDT, SD Bioline Dengue Duo NS1/IgM/IgG combo - a commercially available RDT, and SD Dengue NS1 Ag enzyme-linked immunosorbent assay (ELISA), for the diagnosis of acute dengue infection. METHODS: This prospective cross-sectional study consecutively recruited 494 patients with suspected dengue from a health clinic in Malaysia. Both RDTs were performed onsite. The evaluated ELISA and reference tests were performed in a virology laboratory. The reference tests comprised of a reverse transcription-polymerase chain reaction and three ELISAs for the detection of dengue NS1 antigen, IgM and IgG antibodies, respectively. The diagnostic performance of evaluated tests was computed using STATA version 12. RESULTS: The sensitivity and specificity of ViroTrack were 62.3% (95%CI 55.6–68.7) and 95.0% (95%CI 91.7–97.3), versus 66.5% (95%CI 60.0–72.6) and 95.4% (95%CI 92.1–97.6) for SD NS1 ELISA, and 52.4% (95%CI 45.7–59.1) and 97.7% (95%CI 95.1–99.2) for NS1 component of SD Bioline, respectively. The combination of the latter with its IgM and IgG components were able to increase test sensitivity to 82.4% (95%CI 76.8–87.1) with corresponding decrease in specificity to 87.4% (95%CI 82.8–91.2). Although a positive test on any of the NS1 assays would increase the probability of dengue to above 90% in a patient, a negative result would only reduce this probability to 23.0–29.3%. In contrast, this probability of false negative diagnosis would be further reduced to 14.7% (95%CI 11.4–18.6) if SD Bioline NS1/IgM/IgG combo was negative. CONCLUSIONS: The performance of ViroTrack Dengue Acute was comparable to SD Dengue NS1 Ag ELISA. Addition of serology components to SD Bioline Dengue Duo significantly improved its sensitivity and reduced its false negative rate such that it missed the fewest dengue patients, making it a better point-of-care diagnostic tool. New RDT like ViroTrack Dengue Acute may be a potential alternative to existing RDT if its combination with serology components is proven better in future studies. BioMed Central 2020-03-12 /pmc/articles/PMC7069157/ /pubmed/32164538 http://dx.doi.org/10.1186/s12879-020-4911-5 Text en © The Author(s). 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Chong, Zhuo Lin Sekaran, Shamala Devi Soe, Hui Jen Peramalah, Devi Rampal, Sanjay Ng, Chiu-Wan Diagnostic accuracy and utility of three dengue diagnostic tests for the diagnosis of acute dengue infection in Malaysia |
title | Diagnostic accuracy and utility of three dengue diagnostic tests for the diagnosis of acute dengue infection in Malaysia |
title_full | Diagnostic accuracy and utility of three dengue diagnostic tests for the diagnosis of acute dengue infection in Malaysia |
title_fullStr | Diagnostic accuracy and utility of three dengue diagnostic tests for the diagnosis of acute dengue infection in Malaysia |
title_full_unstemmed | Diagnostic accuracy and utility of three dengue diagnostic tests for the diagnosis of acute dengue infection in Malaysia |
title_short | Diagnostic accuracy and utility of three dengue diagnostic tests for the diagnosis of acute dengue infection in Malaysia |
title_sort | diagnostic accuracy and utility of three dengue diagnostic tests for the diagnosis of acute dengue infection in malaysia |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7069157/ https://www.ncbi.nlm.nih.gov/pubmed/32164538 http://dx.doi.org/10.1186/s12879-020-4911-5 |
work_keys_str_mv | AT chongzhuolin diagnosticaccuracyandutilityofthreedenguediagnostictestsforthediagnosisofacutedengueinfectioninmalaysia AT sekaranshamaladevi diagnosticaccuracyandutilityofthreedenguediagnostictestsforthediagnosisofacutedengueinfectioninmalaysia AT soehuijen diagnosticaccuracyandutilityofthreedenguediagnostictestsforthediagnosisofacutedengueinfectioninmalaysia AT peramalahdevi diagnosticaccuracyandutilityofthreedenguediagnostictestsforthediagnosisofacutedengueinfectioninmalaysia AT rampalsanjay diagnosticaccuracyandutilityofthreedenguediagnostictestsforthediagnosisofacutedengueinfectioninmalaysia AT ngchiuwan diagnosticaccuracyandutilityofthreedenguediagnostictestsforthediagnosisofacutedengueinfectioninmalaysia |