Cargando…
Application of Continuous Intraoperative Neuromonitoring During VATS Lobectomy for Left Lung Cancer to Prevent Recurrent Laryngeal Nerve Injury
We applied continuous intraoperative neuromonitoring (CIONM) during video-assisted thoracoscopic surgery (VATS) lobectomy for left lung cancer and evaluated its safety and usefulness. An electrode was attached to a double-lumen tube, and placed at vocal cord level to detect the EMG signal evoked by...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7069963/ https://www.ncbi.nlm.nih.gov/pubmed/32170087 http://dx.doi.org/10.1038/s41598-020-61500-6 |
_version_ | 1783505876716355584 |
---|---|
author | Chai, Young Jun Lee, Jung-Man Seong, Yong Won Moon, Hyeon Jong |
author_facet | Chai, Young Jun Lee, Jung-Man Seong, Yong Won Moon, Hyeon Jong |
author_sort | Chai, Young Jun |
collection | PubMed |
description | We applied continuous intraoperative neuromonitoring (CIONM) during video-assisted thoracoscopic surgery (VATS) lobectomy for left lung cancer and evaluated its safety and usefulness. An electrode was attached to a double-lumen tube, and placed at vocal cord level to detect the EMG signal evoked by vocal cord movement. Before 4 L lymph node dissection, an automatic periodic stimulation device was applied to the vagus nerve to stimulate vagus nerve continuously. Surgery was suspended if the amplitude decreased lower than the threshold and was resumed when the amplitude recovered. Ten patients (6 male, 4 female) were enrolled. CIONM was successfully performed in all patients without technical failure, and there was no hemodynamic instability. Amplitude decreased below the threshold in four patients. One patient did not recover amplitude and experienced transient vocal cord palsy. In the three other patients, the amplitude recovered above the threshold and no vocal cord palsy occurred. The six patients who did not exhibit amplitude decrease experienced no vocal cord palsy. Our results suggest that CIONM may be applied safely for VATS left lobectomy and may be used to predict postoperative vocal cord function. This approach may be helpful to prevent RLN injury during VATS left lobectomy. |
format | Online Article Text |
id | pubmed-7069963 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-70699632020-03-22 Application of Continuous Intraoperative Neuromonitoring During VATS Lobectomy for Left Lung Cancer to Prevent Recurrent Laryngeal Nerve Injury Chai, Young Jun Lee, Jung-Man Seong, Yong Won Moon, Hyeon Jong Sci Rep Article We applied continuous intraoperative neuromonitoring (CIONM) during video-assisted thoracoscopic surgery (VATS) lobectomy for left lung cancer and evaluated its safety and usefulness. An electrode was attached to a double-lumen tube, and placed at vocal cord level to detect the EMG signal evoked by vocal cord movement. Before 4 L lymph node dissection, an automatic periodic stimulation device was applied to the vagus nerve to stimulate vagus nerve continuously. Surgery was suspended if the amplitude decreased lower than the threshold and was resumed when the amplitude recovered. Ten patients (6 male, 4 female) were enrolled. CIONM was successfully performed in all patients without technical failure, and there was no hemodynamic instability. Amplitude decreased below the threshold in four patients. One patient did not recover amplitude and experienced transient vocal cord palsy. In the three other patients, the amplitude recovered above the threshold and no vocal cord palsy occurred. The six patients who did not exhibit amplitude decrease experienced no vocal cord palsy. Our results suggest that CIONM may be applied safely for VATS left lobectomy and may be used to predict postoperative vocal cord function. This approach may be helpful to prevent RLN injury during VATS left lobectomy. Nature Publishing Group UK 2020-03-13 /pmc/articles/PMC7069963/ /pubmed/32170087 http://dx.doi.org/10.1038/s41598-020-61500-6 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Chai, Young Jun Lee, Jung-Man Seong, Yong Won Moon, Hyeon Jong Application of Continuous Intraoperative Neuromonitoring During VATS Lobectomy for Left Lung Cancer to Prevent Recurrent Laryngeal Nerve Injury |
title | Application of Continuous Intraoperative Neuromonitoring During VATS Lobectomy for Left Lung Cancer to Prevent Recurrent Laryngeal Nerve Injury |
title_full | Application of Continuous Intraoperative Neuromonitoring During VATS Lobectomy for Left Lung Cancer to Prevent Recurrent Laryngeal Nerve Injury |
title_fullStr | Application of Continuous Intraoperative Neuromonitoring During VATS Lobectomy for Left Lung Cancer to Prevent Recurrent Laryngeal Nerve Injury |
title_full_unstemmed | Application of Continuous Intraoperative Neuromonitoring During VATS Lobectomy for Left Lung Cancer to Prevent Recurrent Laryngeal Nerve Injury |
title_short | Application of Continuous Intraoperative Neuromonitoring During VATS Lobectomy for Left Lung Cancer to Prevent Recurrent Laryngeal Nerve Injury |
title_sort | application of continuous intraoperative neuromonitoring during vats lobectomy for left lung cancer to prevent recurrent laryngeal nerve injury |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7069963/ https://www.ncbi.nlm.nih.gov/pubmed/32170087 http://dx.doi.org/10.1038/s41598-020-61500-6 |
work_keys_str_mv | AT chaiyoungjun applicationofcontinuousintraoperativeneuromonitoringduringvatslobectomyforleftlungcancertopreventrecurrentlaryngealnerveinjury AT leejungman applicationofcontinuousintraoperativeneuromonitoringduringvatslobectomyforleftlungcancertopreventrecurrentlaryngealnerveinjury AT seongyongwon applicationofcontinuousintraoperativeneuromonitoringduringvatslobectomyforleftlungcancertopreventrecurrentlaryngealnerveinjury AT moonhyeonjong applicationofcontinuousintraoperativeneuromonitoringduringvatslobectomyforleftlungcancertopreventrecurrentlaryngealnerveinjury |