Cargando…

Development of a Unified Reversed-Phase HPLC Method for Efficient Determination of EP and USP Process-Related Impurities in Celecoxib Using Analytical Quality by Design Principles

This article presents the development of a reversed-phase (RP) high-performance liquid chromatographic (HPLC) method for determination of process-related impurities in a celecoxib drug substance following Analytical Quality by Design (AQbD) principles. The method from European Pharmacopeia (EP) for...

Descripción completa

Detalles Bibliográficos
Autores principales: Tome, Tim, Časar, Zdenko, Obreza, Aleš
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7070322/
https://www.ncbi.nlm.nih.gov/pubmed/32069880
http://dx.doi.org/10.3390/molecules25040809
_version_ 1783505948249161728
author Tome, Tim
Časar, Zdenko
Obreza, Aleš
author_facet Tome, Tim
Časar, Zdenko
Obreza, Aleš
author_sort Tome, Tim
collection PubMed
description This article presents the development of a reversed-phase (RP) high-performance liquid chromatographic (HPLC) method for determination of process-related impurities in a celecoxib drug substance following Analytical Quality by Design (AQbD) principles. The method from European Pharmacopeia (EP) for celecoxib drug substance does not sufficiently separate celecoxib from its EP impurity B because the system suitability criterion is not achieved (resolution NLT 1.8). The same issue was observed with the proposed method from United States Pharmacopeia (USP) for celecoxib capsules, where EP impurity A elutes under the main peak. A new HPLC method was developed that eliminates the disadvantages of the two pharmacopeial methods and is capable of efficiently separating and determining all seven impurities listed in EP and the proposed USP monographs. The development of a new HPLC method started with method scouting, in which various C18 and phenyl stationary phases were tested. Improved selectivity was obtained only with a chiral stationary phase. An immobilized Chiralpak IA-3 column used in RP mode turned out to be the most appropriate for method optimization. The ratio of acetonitrile in the mobile phase, flow rate, and column temperature were recognized as critical method parameters (CMPs) and were further investigated using a central composite face response-surface design. A multiple linear regression (MLR) method was applied to fit the mathematical models on the experimental data to determine factor–response relationships. The models created show adequate fit and good prediction abilities. The Monte Carlo simulation method was used to establish the design space. The method developed was verified in terms of precision, sensitivity, accuracy, and linearity, and the results showed that the new method is suitable for determination of seven process-related impurities of celecoxib.
format Online
Article
Text
id pubmed-7070322
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-70703222020-03-19 Development of a Unified Reversed-Phase HPLC Method for Efficient Determination of EP and USP Process-Related Impurities in Celecoxib Using Analytical Quality by Design Principles Tome, Tim Časar, Zdenko Obreza, Aleš Molecules Article This article presents the development of a reversed-phase (RP) high-performance liquid chromatographic (HPLC) method for determination of process-related impurities in a celecoxib drug substance following Analytical Quality by Design (AQbD) principles. The method from European Pharmacopeia (EP) for celecoxib drug substance does not sufficiently separate celecoxib from its EP impurity B because the system suitability criterion is not achieved (resolution NLT 1.8). The same issue was observed with the proposed method from United States Pharmacopeia (USP) for celecoxib capsules, where EP impurity A elutes under the main peak. A new HPLC method was developed that eliminates the disadvantages of the two pharmacopeial methods and is capable of efficiently separating and determining all seven impurities listed in EP and the proposed USP monographs. The development of a new HPLC method started with method scouting, in which various C18 and phenyl stationary phases were tested. Improved selectivity was obtained only with a chiral stationary phase. An immobilized Chiralpak IA-3 column used in RP mode turned out to be the most appropriate for method optimization. The ratio of acetonitrile in the mobile phase, flow rate, and column temperature were recognized as critical method parameters (CMPs) and were further investigated using a central composite face response-surface design. A multiple linear regression (MLR) method was applied to fit the mathematical models on the experimental data to determine factor–response relationships. The models created show adequate fit and good prediction abilities. The Monte Carlo simulation method was used to establish the design space. The method developed was verified in terms of precision, sensitivity, accuracy, and linearity, and the results showed that the new method is suitable for determination of seven process-related impurities of celecoxib. MDPI 2020-02-13 /pmc/articles/PMC7070322/ /pubmed/32069880 http://dx.doi.org/10.3390/molecules25040809 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Tome, Tim
Časar, Zdenko
Obreza, Aleš
Development of a Unified Reversed-Phase HPLC Method for Efficient Determination of EP and USP Process-Related Impurities in Celecoxib Using Analytical Quality by Design Principles
title Development of a Unified Reversed-Phase HPLC Method for Efficient Determination of EP and USP Process-Related Impurities in Celecoxib Using Analytical Quality by Design Principles
title_full Development of a Unified Reversed-Phase HPLC Method for Efficient Determination of EP and USP Process-Related Impurities in Celecoxib Using Analytical Quality by Design Principles
title_fullStr Development of a Unified Reversed-Phase HPLC Method for Efficient Determination of EP and USP Process-Related Impurities in Celecoxib Using Analytical Quality by Design Principles
title_full_unstemmed Development of a Unified Reversed-Phase HPLC Method for Efficient Determination of EP and USP Process-Related Impurities in Celecoxib Using Analytical Quality by Design Principles
title_short Development of a Unified Reversed-Phase HPLC Method for Efficient Determination of EP and USP Process-Related Impurities in Celecoxib Using Analytical Quality by Design Principles
title_sort development of a unified reversed-phase hplc method for efficient determination of ep and usp process-related impurities in celecoxib using analytical quality by design principles
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7070322/
https://www.ncbi.nlm.nih.gov/pubmed/32069880
http://dx.doi.org/10.3390/molecules25040809
work_keys_str_mv AT tometim developmentofaunifiedreversedphasehplcmethodforefficientdeterminationofepanduspprocessrelatedimpuritiesincelecoxibusinganalyticalqualitybydesignprinciples
AT casarzdenko developmentofaunifiedreversedphasehplcmethodforefficientdeterminationofepanduspprocessrelatedimpuritiesincelecoxibusinganalyticalqualitybydesignprinciples
AT obrezaales developmentofaunifiedreversedphasehplcmethodforefficientdeterminationofepanduspprocessrelatedimpuritiesincelecoxibusinganalyticalqualitybydesignprinciples