Cargando…
Detecting of the Longitudinal Grouting Quality in Prestressed Curved Tendon Duct Using Piezoceramic Transducers
To understand the characteristics of longitudinal grouting quality, this paper developed a stress wave-based active sensing method using piezoceramic transducers to detect longitudinal grouting quality of the prestressed curved tendon ducts. There were four lead zirconate titanate (PZT) transducers...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7070417/ https://www.ncbi.nlm.nih.gov/pubmed/32098433 http://dx.doi.org/10.3390/s20041212 |
_version_ | 1783505970607947776 |
---|---|
author | Jiang, Tianyong He, Bin Zhang, Yaowen Wang, Lei |
author_facet | Jiang, Tianyong He, Bin Zhang, Yaowen Wang, Lei |
author_sort | Jiang, Tianyong |
collection | PubMed |
description | To understand the characteristics of longitudinal grouting quality, this paper developed a stress wave-based active sensing method using piezoceramic transducers to detect longitudinal grouting quality of the prestressed curved tendon ducts. There were four lead zirconate titanate (PZT) transducers installed in the same longitudinal plane. One of them, mounted on the bottom of the curved tendon duct, was called as an actuator for generating stress waves. The other three, pasted on the top of the curved tendon duct, were called as sensors for detecting the wave responses. The experimental process was divided into five states during the grouting, which included 0%, 50%, 75%, 90%, and 100% grouting. The voltage signals, power spectral density (PSD) energy and wavelet packet energy were adopted in this research. Experimental results showed that all the amplitudes of the above analysis indicators were small before the grouting reached 90%. Only when the grouting degree reached the 100% grouting, these parameters increased significantly. The results of different longitudinal PZT sensors were mainly determined by the distance from the generator, the position of grouting holes, and the fluidity of grouting materials. These results showed the longitudinal grouting quality can be effectively evaluated by analyzing the difference between the signals received by the PZT transducers in the curved tendon duct. The devised method has certain application value in detecting the longitudinal grouting quality of prestressed curved tendon duct. |
format | Online Article Text |
id | pubmed-7070417 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-70704172020-03-19 Detecting of the Longitudinal Grouting Quality in Prestressed Curved Tendon Duct Using Piezoceramic Transducers Jiang, Tianyong He, Bin Zhang, Yaowen Wang, Lei Sensors (Basel) Article To understand the characteristics of longitudinal grouting quality, this paper developed a stress wave-based active sensing method using piezoceramic transducers to detect longitudinal grouting quality of the prestressed curved tendon ducts. There were four lead zirconate titanate (PZT) transducers installed in the same longitudinal plane. One of them, mounted on the bottom of the curved tendon duct, was called as an actuator for generating stress waves. The other three, pasted on the top of the curved tendon duct, were called as sensors for detecting the wave responses. The experimental process was divided into five states during the grouting, which included 0%, 50%, 75%, 90%, and 100% grouting. The voltage signals, power spectral density (PSD) energy and wavelet packet energy were adopted in this research. Experimental results showed that all the amplitudes of the above analysis indicators were small before the grouting reached 90%. Only when the grouting degree reached the 100% grouting, these parameters increased significantly. The results of different longitudinal PZT sensors were mainly determined by the distance from the generator, the position of grouting holes, and the fluidity of grouting materials. These results showed the longitudinal grouting quality can be effectively evaluated by analyzing the difference between the signals received by the PZT transducers in the curved tendon duct. The devised method has certain application value in detecting the longitudinal grouting quality of prestressed curved tendon duct. MDPI 2020-02-22 /pmc/articles/PMC7070417/ /pubmed/32098433 http://dx.doi.org/10.3390/s20041212 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Jiang, Tianyong He, Bin Zhang, Yaowen Wang, Lei Detecting of the Longitudinal Grouting Quality in Prestressed Curved Tendon Duct Using Piezoceramic Transducers |
title | Detecting of the Longitudinal Grouting Quality in Prestressed Curved Tendon Duct Using Piezoceramic Transducers |
title_full | Detecting of the Longitudinal Grouting Quality in Prestressed Curved Tendon Duct Using Piezoceramic Transducers |
title_fullStr | Detecting of the Longitudinal Grouting Quality in Prestressed Curved Tendon Duct Using Piezoceramic Transducers |
title_full_unstemmed | Detecting of the Longitudinal Grouting Quality in Prestressed Curved Tendon Duct Using Piezoceramic Transducers |
title_short | Detecting of the Longitudinal Grouting Quality in Prestressed Curved Tendon Duct Using Piezoceramic Transducers |
title_sort | detecting of the longitudinal grouting quality in prestressed curved tendon duct using piezoceramic transducers |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7070417/ https://www.ncbi.nlm.nih.gov/pubmed/32098433 http://dx.doi.org/10.3390/s20041212 |
work_keys_str_mv | AT jiangtianyong detectingofthelongitudinalgroutingqualityinprestressedcurvedtendonductusingpiezoceramictransducers AT hebin detectingofthelongitudinalgroutingqualityinprestressedcurvedtendonductusingpiezoceramictransducers AT zhangyaowen detectingofthelongitudinalgroutingqualityinprestressedcurvedtendonductusingpiezoceramictransducers AT wanglei detectingofthelongitudinalgroutingqualityinprestressedcurvedtendonductusingpiezoceramictransducers |