Cargando…

Textile Electrocardiogram (ECG) Electrodes for Wearable Health Monitoring

Wearable health-monitoring systems should be comfortable, non-stigmatizing, and able to achieve high data quality. Smart textiles with electronic elements integrated directly into fabrics offer a way to embed sensors into clothing seamlessly to serve these purposes. In this work, we demonstrate the...

Descripción completa

Detalles Bibliográficos
Autores principales: Arquilla, Katya, Webb, Andrea K., Anderson, Allison P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7070603/
https://www.ncbi.nlm.nih.gov/pubmed/32069937
http://dx.doi.org/10.3390/s20041013
_version_ 1783506013208444928
author Arquilla, Katya
Webb, Andrea K.
Anderson, Allison P.
author_facet Arquilla, Katya
Webb, Andrea K.
Anderson, Allison P.
author_sort Arquilla, Katya
collection PubMed
description Wearable health-monitoring systems should be comfortable, non-stigmatizing, and able to achieve high data quality. Smart textiles with electronic elements integrated directly into fabrics offer a way to embed sensors into clothing seamlessly to serve these purposes. In this work, we demonstrate the feasibility of electrocardiogram (ECG) monitoring with sewn textile electrodes instead of traditional gel electrodes in a 3-lead, chest-mounted configuration. The textile electrodes are sewn with silver-coated thread in an overlapping zig zag pattern into an inextensible fabric. Sensor validation included ECG monitoring and comfort surveys with human subjects, stretch testing, and wash cycling. The electrodes were tested with the BIOPAC MP160 ECG data acquisition module. Sensors were placed on 8 subjects (5 males and 3 females) with double-sided tape. To detect differences in R peak detectability between traditional and sewn sensors, effect size was set at 10% of a sample mean for heart rate (HR) and R-R interval. Paired student’s t-tests were run between adhesive and sewn electrode data for R-R interval and average HR, and a Wilcoxon signed-rank test was run for comfort. No statistically significant difference was found between the traditional and textile electrodes (R-R interval: t = 1.43, p > 0.1; HR: t = −0.70, p > 0.5; comfort: V = 15, p > 0.5).
format Online
Article
Text
id pubmed-7070603
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-70706032020-03-19 Textile Electrocardiogram (ECG) Electrodes for Wearable Health Monitoring Arquilla, Katya Webb, Andrea K. Anderson, Allison P. Sensors (Basel) Article Wearable health-monitoring systems should be comfortable, non-stigmatizing, and able to achieve high data quality. Smart textiles with electronic elements integrated directly into fabrics offer a way to embed sensors into clothing seamlessly to serve these purposes. In this work, we demonstrate the feasibility of electrocardiogram (ECG) monitoring with sewn textile electrodes instead of traditional gel electrodes in a 3-lead, chest-mounted configuration. The textile electrodes are sewn with silver-coated thread in an overlapping zig zag pattern into an inextensible fabric. Sensor validation included ECG monitoring and comfort surveys with human subjects, stretch testing, and wash cycling. The electrodes were tested with the BIOPAC MP160 ECG data acquisition module. Sensors were placed on 8 subjects (5 males and 3 females) with double-sided tape. To detect differences in R peak detectability between traditional and sewn sensors, effect size was set at 10% of a sample mean for heart rate (HR) and R-R interval. Paired student’s t-tests were run between adhesive and sewn electrode data for R-R interval and average HR, and a Wilcoxon signed-rank test was run for comfort. No statistically significant difference was found between the traditional and textile electrodes (R-R interval: t = 1.43, p > 0.1; HR: t = −0.70, p > 0.5; comfort: V = 15, p > 0.5). MDPI 2020-02-13 /pmc/articles/PMC7070603/ /pubmed/32069937 http://dx.doi.org/10.3390/s20041013 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Arquilla, Katya
Webb, Andrea K.
Anderson, Allison P.
Textile Electrocardiogram (ECG) Electrodes for Wearable Health Monitoring
title Textile Electrocardiogram (ECG) Electrodes for Wearable Health Monitoring
title_full Textile Electrocardiogram (ECG) Electrodes for Wearable Health Monitoring
title_fullStr Textile Electrocardiogram (ECG) Electrodes for Wearable Health Monitoring
title_full_unstemmed Textile Electrocardiogram (ECG) Electrodes for Wearable Health Monitoring
title_short Textile Electrocardiogram (ECG) Electrodes for Wearable Health Monitoring
title_sort textile electrocardiogram (ecg) electrodes for wearable health monitoring
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7070603/
https://www.ncbi.nlm.nih.gov/pubmed/32069937
http://dx.doi.org/10.3390/s20041013
work_keys_str_mv AT arquillakatya textileelectrocardiogramecgelectrodesforwearablehealthmonitoring
AT webbandreak textileelectrocardiogramecgelectrodesforwearablehealthmonitoring
AT andersonallisonp textileelectrocardiogramecgelectrodesforwearablehealthmonitoring