Cargando…
Textile Electrocardiogram (ECG) Electrodes for Wearable Health Monitoring
Wearable health-monitoring systems should be comfortable, non-stigmatizing, and able to achieve high data quality. Smart textiles with electronic elements integrated directly into fabrics offer a way to embed sensors into clothing seamlessly to serve these purposes. In this work, we demonstrate the...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7070603/ https://www.ncbi.nlm.nih.gov/pubmed/32069937 http://dx.doi.org/10.3390/s20041013 |
_version_ | 1783506013208444928 |
---|---|
author | Arquilla, Katya Webb, Andrea K. Anderson, Allison P. |
author_facet | Arquilla, Katya Webb, Andrea K. Anderson, Allison P. |
author_sort | Arquilla, Katya |
collection | PubMed |
description | Wearable health-monitoring systems should be comfortable, non-stigmatizing, and able to achieve high data quality. Smart textiles with electronic elements integrated directly into fabrics offer a way to embed sensors into clothing seamlessly to serve these purposes. In this work, we demonstrate the feasibility of electrocardiogram (ECG) monitoring with sewn textile electrodes instead of traditional gel electrodes in a 3-lead, chest-mounted configuration. The textile electrodes are sewn with silver-coated thread in an overlapping zig zag pattern into an inextensible fabric. Sensor validation included ECG monitoring and comfort surveys with human subjects, stretch testing, and wash cycling. The electrodes were tested with the BIOPAC MP160 ECG data acquisition module. Sensors were placed on 8 subjects (5 males and 3 females) with double-sided tape. To detect differences in R peak detectability between traditional and sewn sensors, effect size was set at 10% of a sample mean for heart rate (HR) and R-R interval. Paired student’s t-tests were run between adhesive and sewn electrode data for R-R interval and average HR, and a Wilcoxon signed-rank test was run for comfort. No statistically significant difference was found between the traditional and textile electrodes (R-R interval: t = 1.43, p > 0.1; HR: t = −0.70, p > 0.5; comfort: V = 15, p > 0.5). |
format | Online Article Text |
id | pubmed-7070603 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-70706032020-03-19 Textile Electrocardiogram (ECG) Electrodes for Wearable Health Monitoring Arquilla, Katya Webb, Andrea K. Anderson, Allison P. Sensors (Basel) Article Wearable health-monitoring systems should be comfortable, non-stigmatizing, and able to achieve high data quality. Smart textiles with electronic elements integrated directly into fabrics offer a way to embed sensors into clothing seamlessly to serve these purposes. In this work, we demonstrate the feasibility of electrocardiogram (ECG) monitoring with sewn textile electrodes instead of traditional gel electrodes in a 3-lead, chest-mounted configuration. The textile electrodes are sewn with silver-coated thread in an overlapping zig zag pattern into an inextensible fabric. Sensor validation included ECG monitoring and comfort surveys with human subjects, stretch testing, and wash cycling. The electrodes were tested with the BIOPAC MP160 ECG data acquisition module. Sensors were placed on 8 subjects (5 males and 3 females) with double-sided tape. To detect differences in R peak detectability between traditional and sewn sensors, effect size was set at 10% of a sample mean for heart rate (HR) and R-R interval. Paired student’s t-tests were run between adhesive and sewn electrode data for R-R interval and average HR, and a Wilcoxon signed-rank test was run for comfort. No statistically significant difference was found between the traditional and textile electrodes (R-R interval: t = 1.43, p > 0.1; HR: t = −0.70, p > 0.5; comfort: V = 15, p > 0.5). MDPI 2020-02-13 /pmc/articles/PMC7070603/ /pubmed/32069937 http://dx.doi.org/10.3390/s20041013 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Arquilla, Katya Webb, Andrea K. Anderson, Allison P. Textile Electrocardiogram (ECG) Electrodes for Wearable Health Monitoring |
title | Textile Electrocardiogram (ECG) Electrodes for Wearable Health Monitoring |
title_full | Textile Electrocardiogram (ECG) Electrodes for Wearable Health Monitoring |
title_fullStr | Textile Electrocardiogram (ECG) Electrodes for Wearable Health Monitoring |
title_full_unstemmed | Textile Electrocardiogram (ECG) Electrodes for Wearable Health Monitoring |
title_short | Textile Electrocardiogram (ECG) Electrodes for Wearable Health Monitoring |
title_sort | textile electrocardiogram (ecg) electrodes for wearable health monitoring |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7070603/ https://www.ncbi.nlm.nih.gov/pubmed/32069937 http://dx.doi.org/10.3390/s20041013 |
work_keys_str_mv | AT arquillakatya textileelectrocardiogramecgelectrodesforwearablehealthmonitoring AT webbandreak textileelectrocardiogramecgelectrodesforwearablehealthmonitoring AT andersonallisonp textileelectrocardiogramecgelectrodesforwearablehealthmonitoring |