Accuracy of CAD/CAM Digital Impressions with Different Intraoral Scanner Parameters

The advancement of intraoral scanners has allowed for more efficient workflow in the dental clinical setting. However, limited data exist regarding the accuracy of the digital impressions produced with various scanner settings and scanning approaches. The purpose of this in vitro study was to compar...

Descripción completa

Detalles Bibliográficos
Autores principales: Chiu, Asher, Chen, Yen-Wei, Hayashi, Juri, Sadr, Alireza
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7071446/
https://www.ncbi.nlm.nih.gov/pubmed/32093174
http://dx.doi.org/10.3390/s20041157
_version_ 1783506203837464576
author Chiu, Asher
Chen, Yen-Wei
Hayashi, Juri
Sadr, Alireza
author_facet Chiu, Asher
Chen, Yen-Wei
Hayashi, Juri
Sadr, Alireza
author_sort Chiu, Asher
collection PubMed
description The advancement of intraoral scanners has allowed for more efficient workflow in the dental clinical setting. However, limited data exist regarding the accuracy of the digital impressions produced with various scanner settings and scanning approaches. The purpose of this in vitro study was to compare the accuracy of digital impressions at the crown preparation margin using different scanning resolutions of a specific intraoral scanner system. An all-ceramic crown preparation of a mandibular first molar was constructed in a typodont, and a scan (n = 3) was created with an industrial-grade laboratory scanner (3Shape D2000) as the control. Digital impressions were obtained with an intraoral scanner (3Shape TRIOS 3) under three settings—high resolution (HR), standard resolution (SR), and combined resolution (SHR). Comparative 3D analysis of scans was performed with Geomagic Control X software to measure the discrepancy between intraoral scans and the control scan along the preparation finish line. The scan time and number of images captured per scan were recorded. Statistical analysis was performed by one-way ANOVA, two-way repeated measures ANOVA, Pearson’s correlation, and Dunnett’s T3 test (α = 0.05). Significant differences were observed for scan time and for number of images captured among scan resolution settings (α < 0.05). The scan time for the SR group was, on average, 34.2 s less than the SHR group and 46.5 s less than the HR group. For discrepancy on the finish line, no significant differences were observed among scanning resolutions (HR: 31.5 ± 5.5 μm, SHR: 33.2 ± 3.7 μm, SR: 33.6 ± 3.1 μm). Significant differences in discrepancy were observed among tooth surfaces, with the distal surface showing the highest discrepancies. In conclusion, the resolution of the intra-oral scanner is primarily defined by the system hardware and optimized for default scans. A software high-resolution mode that obtains more data over a longer time may not necessarily benefit the scan accuracy, while the tooth preparation and surface parameters do affect the accuracy.
format Online
Article
Text
id pubmed-7071446
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-70714462020-03-19 Accuracy of CAD/CAM Digital Impressions with Different Intraoral Scanner Parameters Chiu, Asher Chen, Yen-Wei Hayashi, Juri Sadr, Alireza Sensors (Basel) Article The advancement of intraoral scanners has allowed for more efficient workflow in the dental clinical setting. However, limited data exist regarding the accuracy of the digital impressions produced with various scanner settings and scanning approaches. The purpose of this in vitro study was to compare the accuracy of digital impressions at the crown preparation margin using different scanning resolutions of a specific intraoral scanner system. An all-ceramic crown preparation of a mandibular first molar was constructed in a typodont, and a scan (n = 3) was created with an industrial-grade laboratory scanner (3Shape D2000) as the control. Digital impressions were obtained with an intraoral scanner (3Shape TRIOS 3) under three settings—high resolution (HR), standard resolution (SR), and combined resolution (SHR). Comparative 3D analysis of scans was performed with Geomagic Control X software to measure the discrepancy between intraoral scans and the control scan along the preparation finish line. The scan time and number of images captured per scan were recorded. Statistical analysis was performed by one-way ANOVA, two-way repeated measures ANOVA, Pearson’s correlation, and Dunnett’s T3 test (α = 0.05). Significant differences were observed for scan time and for number of images captured among scan resolution settings (α < 0.05). The scan time for the SR group was, on average, 34.2 s less than the SHR group and 46.5 s less than the HR group. For discrepancy on the finish line, no significant differences were observed among scanning resolutions (HR: 31.5 ± 5.5 μm, SHR: 33.2 ± 3.7 μm, SR: 33.6 ± 3.1 μm). Significant differences in discrepancy were observed among tooth surfaces, with the distal surface showing the highest discrepancies. In conclusion, the resolution of the intra-oral scanner is primarily defined by the system hardware and optimized for default scans. A software high-resolution mode that obtains more data over a longer time may not necessarily benefit the scan accuracy, while the tooth preparation and surface parameters do affect the accuracy. MDPI 2020-02-20 /pmc/articles/PMC7071446/ /pubmed/32093174 http://dx.doi.org/10.3390/s20041157 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Chiu, Asher
Chen, Yen-Wei
Hayashi, Juri
Sadr, Alireza
Accuracy of CAD/CAM Digital Impressions with Different Intraoral Scanner Parameters
title Accuracy of CAD/CAM Digital Impressions with Different Intraoral Scanner Parameters
title_full Accuracy of CAD/CAM Digital Impressions with Different Intraoral Scanner Parameters
title_fullStr Accuracy of CAD/CAM Digital Impressions with Different Intraoral Scanner Parameters
title_full_unstemmed Accuracy of CAD/CAM Digital Impressions with Different Intraoral Scanner Parameters
title_short Accuracy of CAD/CAM Digital Impressions with Different Intraoral Scanner Parameters
title_sort accuracy of cad/cam digital impressions with different intraoral scanner parameters
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7071446/
https://www.ncbi.nlm.nih.gov/pubmed/32093174
http://dx.doi.org/10.3390/s20041157
work_keys_str_mv AT chiuasher accuracyofcadcamdigitalimpressionswithdifferentintraoralscannerparameters
AT chenyenwei accuracyofcadcamdigitalimpressionswithdifferentintraoralscannerparameters
AT hayashijuri accuracyofcadcamdigitalimpressionswithdifferentintraoralscannerparameters
AT sadralireza accuracyofcadcamdigitalimpressionswithdifferentintraoralscannerparameters