Cargando…

Osteoporotic Vertebral Compression Fracture and Single Balloon Extrapedicular Kyphoplasty: Findings and Technical Considerations

OBJECTIVE: To evaluate the functional and radiological outcome of balloon kyphoplasty and to endorse the unilateral single balloon extrapedicular kyphoplasty as practically more feasible and safer method in comparison to the conventional methods. METHODS: Totally, 81 patients were presented to our c...

Descripción completa

Detalles Bibliográficos
Autores principales: Mishra, Pankaj Kumar, Dwivedi, Rishi, Dhillon, Charanjit Singh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Shiraz University of Medical Sciences 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7071935/
https://www.ncbi.nlm.nih.gov/pubmed/32201700
http://dx.doi.org/10.29252/beat-080106
_version_ 1783506304380174336
author Mishra, Pankaj Kumar
Dwivedi, Rishi
Dhillon, Charanjit Singh
author_facet Mishra, Pankaj Kumar
Dwivedi, Rishi
Dhillon, Charanjit Singh
author_sort Mishra, Pankaj Kumar
collection PubMed
description OBJECTIVE: To evaluate the functional and radiological outcome of balloon kyphoplasty and to endorse the unilateral single balloon extrapedicular kyphoplasty as practically more feasible and safer method in comparison to the conventional methods. METHODS: Totally, 81 patients were presented to our center with osteoporotic vertebral compression fracture. Among these, 59 patients (61 vertebrae) were enrolled with stable wedge osteoporotic compression fracture. Pre-operatively percentage of vertebral height loss and kyphotic angle were calculated and single balloon extrapedicular kyphoplasty was performed in all cases. RESULTS: Postoperatively, anterior vertebral height improved to 79.61% of normal subjects. In our study, the mean segmental kyphosis correction following balloon kyphoplasty was 14.27°. Overall incidence of cement leak in our study was 15.25%. CONCLUSION: Although we encountered the few difficulties, but this technique holds the safety and feasibility measures. Furthermore, it is effective in restoring anterior vertebral height, alignment and angle of kyphosis.
format Online
Article
Text
id pubmed-7071935
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Shiraz University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-70719352020-03-20 Osteoporotic Vertebral Compression Fracture and Single Balloon Extrapedicular Kyphoplasty: Findings and Technical Considerations Mishra, Pankaj Kumar Dwivedi, Rishi Dhillon, Charanjit Singh Bull Emerg Trauma Original Article OBJECTIVE: To evaluate the functional and radiological outcome of balloon kyphoplasty and to endorse the unilateral single balloon extrapedicular kyphoplasty as practically more feasible and safer method in comparison to the conventional methods. METHODS: Totally, 81 patients were presented to our center with osteoporotic vertebral compression fracture. Among these, 59 patients (61 vertebrae) were enrolled with stable wedge osteoporotic compression fracture. Pre-operatively percentage of vertebral height loss and kyphotic angle were calculated and single balloon extrapedicular kyphoplasty was performed in all cases. RESULTS: Postoperatively, anterior vertebral height improved to 79.61% of normal subjects. In our study, the mean segmental kyphosis correction following balloon kyphoplasty was 14.27°. Overall incidence of cement leak in our study was 15.25%. CONCLUSION: Although we encountered the few difficulties, but this technique holds the safety and feasibility measures. Furthermore, it is effective in restoring anterior vertebral height, alignment and angle of kyphosis. Shiraz University of Medical Sciences 2020-01 /pmc/articles/PMC7071935/ /pubmed/32201700 http://dx.doi.org/10.29252/beat-080106 Text en This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Mishra, Pankaj Kumar
Dwivedi, Rishi
Dhillon, Charanjit Singh
Osteoporotic Vertebral Compression Fracture and Single Balloon Extrapedicular Kyphoplasty: Findings and Technical Considerations
title Osteoporotic Vertebral Compression Fracture and Single Balloon Extrapedicular Kyphoplasty: Findings and Technical Considerations
title_full Osteoporotic Vertebral Compression Fracture and Single Balloon Extrapedicular Kyphoplasty: Findings and Technical Considerations
title_fullStr Osteoporotic Vertebral Compression Fracture and Single Balloon Extrapedicular Kyphoplasty: Findings and Technical Considerations
title_full_unstemmed Osteoporotic Vertebral Compression Fracture and Single Balloon Extrapedicular Kyphoplasty: Findings and Technical Considerations
title_short Osteoporotic Vertebral Compression Fracture and Single Balloon Extrapedicular Kyphoplasty: Findings and Technical Considerations
title_sort osteoporotic vertebral compression fracture and single balloon extrapedicular kyphoplasty: findings and technical considerations
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7071935/
https://www.ncbi.nlm.nih.gov/pubmed/32201700
http://dx.doi.org/10.29252/beat-080106
work_keys_str_mv AT mishrapankajkumar osteoporoticvertebralcompressionfractureandsingleballoonextrapedicularkyphoplastyfindingsandtechnicalconsiderations
AT dwivedirishi osteoporoticvertebralcompressionfractureandsingleballoonextrapedicularkyphoplastyfindingsandtechnicalconsiderations
AT dhilloncharanjitsingh osteoporoticvertebralcompressionfractureandsingleballoonextrapedicularkyphoplastyfindingsandtechnicalconsiderations