Cargando…
Osteoporotic Vertebral Compression Fracture and Single Balloon Extrapedicular Kyphoplasty: Findings and Technical Considerations
OBJECTIVE: To evaluate the functional and radiological outcome of balloon kyphoplasty and to endorse the unilateral single balloon extrapedicular kyphoplasty as practically more feasible and safer method in comparison to the conventional methods. METHODS: Totally, 81 patients were presented to our c...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Shiraz University of Medical Sciences
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7071935/ https://www.ncbi.nlm.nih.gov/pubmed/32201700 http://dx.doi.org/10.29252/beat-080106 |
_version_ | 1783506304380174336 |
---|---|
author | Mishra, Pankaj Kumar Dwivedi, Rishi Dhillon, Charanjit Singh |
author_facet | Mishra, Pankaj Kumar Dwivedi, Rishi Dhillon, Charanjit Singh |
author_sort | Mishra, Pankaj Kumar |
collection | PubMed |
description | OBJECTIVE: To evaluate the functional and radiological outcome of balloon kyphoplasty and to endorse the unilateral single balloon extrapedicular kyphoplasty as practically more feasible and safer method in comparison to the conventional methods. METHODS: Totally, 81 patients were presented to our center with osteoporotic vertebral compression fracture. Among these, 59 patients (61 vertebrae) were enrolled with stable wedge osteoporotic compression fracture. Pre-operatively percentage of vertebral height loss and kyphotic angle were calculated and single balloon extrapedicular kyphoplasty was performed in all cases. RESULTS: Postoperatively, anterior vertebral height improved to 79.61% of normal subjects. In our study, the mean segmental kyphosis correction following balloon kyphoplasty was 14.27°. Overall incidence of cement leak in our study was 15.25%. CONCLUSION: Although we encountered the few difficulties, but this technique holds the safety and feasibility measures. Furthermore, it is effective in restoring anterior vertebral height, alignment and angle of kyphosis. |
format | Online Article Text |
id | pubmed-7071935 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Shiraz University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-70719352020-03-20 Osteoporotic Vertebral Compression Fracture and Single Balloon Extrapedicular Kyphoplasty: Findings and Technical Considerations Mishra, Pankaj Kumar Dwivedi, Rishi Dhillon, Charanjit Singh Bull Emerg Trauma Original Article OBJECTIVE: To evaluate the functional and radiological outcome of balloon kyphoplasty and to endorse the unilateral single balloon extrapedicular kyphoplasty as practically more feasible and safer method in comparison to the conventional methods. METHODS: Totally, 81 patients were presented to our center with osteoporotic vertebral compression fracture. Among these, 59 patients (61 vertebrae) were enrolled with stable wedge osteoporotic compression fracture. Pre-operatively percentage of vertebral height loss and kyphotic angle were calculated and single balloon extrapedicular kyphoplasty was performed in all cases. RESULTS: Postoperatively, anterior vertebral height improved to 79.61% of normal subjects. In our study, the mean segmental kyphosis correction following balloon kyphoplasty was 14.27°. Overall incidence of cement leak in our study was 15.25%. CONCLUSION: Although we encountered the few difficulties, but this technique holds the safety and feasibility measures. Furthermore, it is effective in restoring anterior vertebral height, alignment and angle of kyphosis. Shiraz University of Medical Sciences 2020-01 /pmc/articles/PMC7071935/ /pubmed/32201700 http://dx.doi.org/10.29252/beat-080106 Text en This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Mishra, Pankaj Kumar Dwivedi, Rishi Dhillon, Charanjit Singh Osteoporotic Vertebral Compression Fracture and Single Balloon Extrapedicular Kyphoplasty: Findings and Technical Considerations |
title | Osteoporotic Vertebral Compression Fracture and Single Balloon Extrapedicular Kyphoplasty: Findings and Technical Considerations |
title_full | Osteoporotic Vertebral Compression Fracture and Single Balloon Extrapedicular Kyphoplasty: Findings and Technical Considerations |
title_fullStr | Osteoporotic Vertebral Compression Fracture and Single Balloon Extrapedicular Kyphoplasty: Findings and Technical Considerations |
title_full_unstemmed | Osteoporotic Vertebral Compression Fracture and Single Balloon Extrapedicular Kyphoplasty: Findings and Technical Considerations |
title_short | Osteoporotic Vertebral Compression Fracture and Single Balloon Extrapedicular Kyphoplasty: Findings and Technical Considerations |
title_sort | osteoporotic vertebral compression fracture and single balloon extrapedicular kyphoplasty: findings and technical considerations |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7071935/ https://www.ncbi.nlm.nih.gov/pubmed/32201700 http://dx.doi.org/10.29252/beat-080106 |
work_keys_str_mv | AT mishrapankajkumar osteoporoticvertebralcompressionfractureandsingleballoonextrapedicularkyphoplastyfindingsandtechnicalconsiderations AT dwivedirishi osteoporoticvertebralcompressionfractureandsingleballoonextrapedicularkyphoplastyfindingsandtechnicalconsiderations AT dhilloncharanjitsingh osteoporoticvertebralcompressionfractureandsingleballoonextrapedicularkyphoplastyfindingsandtechnicalconsiderations |