Cargando…
The Vascular Index of Superb Microvascular Imaging Can Improve the Diagnostic Accuracy for Breast Imaging Reporting and Data System Category 4 Breast Lesions
PURPOSE: To investigate whether the vascular index (VI) of superb microvascular imaging (SMI) could improve the diagnostic efficiency for BI-RADS 4 breast lesions and reduce the number of unnecessary biopsies. PATIENTS AND METHODS: For this study, we selected 222 consecutive BI-RADS 4 breast lesions...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7073432/ https://www.ncbi.nlm.nih.gov/pubmed/32210624 http://dx.doi.org/10.2147/CMAR.S242101 |
_version_ | 1783506618346897408 |
---|---|
author | Cai, Si-Man Wang, Hong-Yan Zhang, Xiao-Yan Zhang, Li Zhu, Qing-Li Li, Jian-Chu Sun, Qiang Jiang, Yu-Xin |
author_facet | Cai, Si-Man Wang, Hong-Yan Zhang, Xiao-Yan Zhang, Li Zhu, Qing-Li Li, Jian-Chu Sun, Qiang Jiang, Yu-Xin |
author_sort | Cai, Si-Man |
collection | PubMed |
description | PURPOSE: To investigate whether the vascular index (VI) of superb microvascular imaging (SMI) could improve the diagnostic efficiency for BI-RADS 4 breast lesions and reduce the number of unnecessary biopsies. PATIENTS AND METHODS: For this study, we selected 222 consecutive BI-RADS 4 breast lesions detected by ultrasound and confirmed by pathology from January 2016 to October 2018. A VI of 4.0 was set as the cutoff value to degrade BI-RADS classification. We calculated the accuracy, sensitivity and PPV of a BI-RADS diagnosis alone and the combination of BI-RADS and the VI. RESULTS: Pathologically, of the 222 lesions, 129 were confirmed to be benign, and 93 were found to be malignant. A VI of 4.0 was set as the cutoff value; when the VI≤4.0, those BI-RADS 4 masses were downgraded one level (4C-4B, 4B-4A, 4A-3) to an integral BI-RADS grade, while the others maintained the conventional grade. A total of 54 BI-RADS 4 lesions were degraded to BI-RADS 3, including 53 benign lesions and 1 malignant lesion. The diagnostic accuracy (65.3% vs 41.9%) and PPV (54.8% vs 41.9%) were significantly improved. The sensitivity decreased slightly (98.9% vs 100%) because 1 of the 54 downgraded BI-RADS 4 lesions, which had a pathological type of invasive ductal carcinoma, was incorrectly downgraded. CONCLUSION: SMI is a noninvasive tool for visualizing the vascular structure with high-resolution microvascular images. As a quantitative index, the VI can be used to appropriately downgrade benign lesions classified as BI-RADS 4, which can improve the diagnostic accuracy and PPV and reduce unnecessary biopsies. |
format | Online Article Text |
id | pubmed-7073432 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-70734322020-03-24 The Vascular Index of Superb Microvascular Imaging Can Improve the Diagnostic Accuracy for Breast Imaging Reporting and Data System Category 4 Breast Lesions Cai, Si-Man Wang, Hong-Yan Zhang, Xiao-Yan Zhang, Li Zhu, Qing-Li Li, Jian-Chu Sun, Qiang Jiang, Yu-Xin Cancer Manag Res Original Research PURPOSE: To investigate whether the vascular index (VI) of superb microvascular imaging (SMI) could improve the diagnostic efficiency for BI-RADS 4 breast lesions and reduce the number of unnecessary biopsies. PATIENTS AND METHODS: For this study, we selected 222 consecutive BI-RADS 4 breast lesions detected by ultrasound and confirmed by pathology from January 2016 to October 2018. A VI of 4.0 was set as the cutoff value to degrade BI-RADS classification. We calculated the accuracy, sensitivity and PPV of a BI-RADS diagnosis alone and the combination of BI-RADS and the VI. RESULTS: Pathologically, of the 222 lesions, 129 were confirmed to be benign, and 93 were found to be malignant. A VI of 4.0 was set as the cutoff value; when the VI≤4.0, those BI-RADS 4 masses were downgraded one level (4C-4B, 4B-4A, 4A-3) to an integral BI-RADS grade, while the others maintained the conventional grade. A total of 54 BI-RADS 4 lesions were degraded to BI-RADS 3, including 53 benign lesions and 1 malignant lesion. The diagnostic accuracy (65.3% vs 41.9%) and PPV (54.8% vs 41.9%) were significantly improved. The sensitivity decreased slightly (98.9% vs 100%) because 1 of the 54 downgraded BI-RADS 4 lesions, which had a pathological type of invasive ductal carcinoma, was incorrectly downgraded. CONCLUSION: SMI is a noninvasive tool for visualizing the vascular structure with high-resolution microvascular images. As a quantitative index, the VI can be used to appropriately downgrade benign lesions classified as BI-RADS 4, which can improve the diagnostic accuracy and PPV and reduce unnecessary biopsies. Dove 2020-03-11 /pmc/articles/PMC7073432/ /pubmed/32210624 http://dx.doi.org/10.2147/CMAR.S242101 Text en © 2020 Cai et al. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Original Research Cai, Si-Man Wang, Hong-Yan Zhang, Xiao-Yan Zhang, Li Zhu, Qing-Li Li, Jian-Chu Sun, Qiang Jiang, Yu-Xin The Vascular Index of Superb Microvascular Imaging Can Improve the Diagnostic Accuracy for Breast Imaging Reporting and Data System Category 4 Breast Lesions |
title | The Vascular Index of Superb Microvascular Imaging Can Improve the Diagnostic Accuracy for Breast Imaging Reporting and Data System Category 4 Breast Lesions |
title_full | The Vascular Index of Superb Microvascular Imaging Can Improve the Diagnostic Accuracy for Breast Imaging Reporting and Data System Category 4 Breast Lesions |
title_fullStr | The Vascular Index of Superb Microvascular Imaging Can Improve the Diagnostic Accuracy for Breast Imaging Reporting and Data System Category 4 Breast Lesions |
title_full_unstemmed | The Vascular Index of Superb Microvascular Imaging Can Improve the Diagnostic Accuracy for Breast Imaging Reporting and Data System Category 4 Breast Lesions |
title_short | The Vascular Index of Superb Microvascular Imaging Can Improve the Diagnostic Accuracy for Breast Imaging Reporting and Data System Category 4 Breast Lesions |
title_sort | vascular index of superb microvascular imaging can improve the diagnostic accuracy for breast imaging reporting and data system category 4 breast lesions |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7073432/ https://www.ncbi.nlm.nih.gov/pubmed/32210624 http://dx.doi.org/10.2147/CMAR.S242101 |
work_keys_str_mv | AT caisiman thevascularindexofsuperbmicrovascularimagingcanimprovethediagnosticaccuracyforbreastimagingreportinganddatasystemcategory4breastlesions AT wanghongyan thevascularindexofsuperbmicrovascularimagingcanimprovethediagnosticaccuracyforbreastimagingreportinganddatasystemcategory4breastlesions AT zhangxiaoyan thevascularindexofsuperbmicrovascularimagingcanimprovethediagnosticaccuracyforbreastimagingreportinganddatasystemcategory4breastlesions AT zhangli thevascularindexofsuperbmicrovascularimagingcanimprovethediagnosticaccuracyforbreastimagingreportinganddatasystemcategory4breastlesions AT zhuqingli thevascularindexofsuperbmicrovascularimagingcanimprovethediagnosticaccuracyforbreastimagingreportinganddatasystemcategory4breastlesions AT lijianchu thevascularindexofsuperbmicrovascularimagingcanimprovethediagnosticaccuracyforbreastimagingreportinganddatasystemcategory4breastlesions AT sunqiang thevascularindexofsuperbmicrovascularimagingcanimprovethediagnosticaccuracyforbreastimagingreportinganddatasystemcategory4breastlesions AT jiangyuxin thevascularindexofsuperbmicrovascularimagingcanimprovethediagnosticaccuracyforbreastimagingreportinganddatasystemcategory4breastlesions AT caisiman vascularindexofsuperbmicrovascularimagingcanimprovethediagnosticaccuracyforbreastimagingreportinganddatasystemcategory4breastlesions AT wanghongyan vascularindexofsuperbmicrovascularimagingcanimprovethediagnosticaccuracyforbreastimagingreportinganddatasystemcategory4breastlesions AT zhangxiaoyan vascularindexofsuperbmicrovascularimagingcanimprovethediagnosticaccuracyforbreastimagingreportinganddatasystemcategory4breastlesions AT zhangli vascularindexofsuperbmicrovascularimagingcanimprovethediagnosticaccuracyforbreastimagingreportinganddatasystemcategory4breastlesions AT zhuqingli vascularindexofsuperbmicrovascularimagingcanimprovethediagnosticaccuracyforbreastimagingreportinganddatasystemcategory4breastlesions AT lijianchu vascularindexofsuperbmicrovascularimagingcanimprovethediagnosticaccuracyforbreastimagingreportinganddatasystemcategory4breastlesions AT sunqiang vascularindexofsuperbmicrovascularimagingcanimprovethediagnosticaccuracyforbreastimagingreportinganddatasystemcategory4breastlesions AT jiangyuxin vascularindexofsuperbmicrovascularimagingcanimprovethediagnosticaccuracyforbreastimagingreportinganddatasystemcategory4breastlesions |