Cargando…
Cortical Bone Trajectory Instrumentation with Vertebroplasty for Osteoporotic Thoracolumbar Compression Fracture
Background: Osteoporotic spinal fractures commonly occur in elderly patients with low bone mineral density. In these cases, percutaneous vertebroplasty or percutaneous kyphoplasty can provide significant pain relief and improve mobility. However, studies have reported both the recurrence of vertebra...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7074157/ https://www.ncbi.nlm.nih.gov/pubmed/32079310 http://dx.doi.org/10.3390/medicina56020082 |
_version_ | 1783506773027586048 |
---|---|
author | Hsu, Wei-Lin Lin, Yu-Hsiang Chuang, Hao-Yu Lee, Han-Chung Chen, Der-Cherng Chu, Yen-Tse Cho, Der-Yang Chen, Chao-Hsuan |
author_facet | Hsu, Wei-Lin Lin, Yu-Hsiang Chuang, Hao-Yu Lee, Han-Chung Chen, Der-Cherng Chu, Yen-Tse Cho, Der-Yang Chen, Chao-Hsuan |
author_sort | Hsu, Wei-Lin |
collection | PubMed |
description | Background: Osteoporotic spinal fractures commonly occur in elderly patients with low bone mineral density. In these cases, percutaneous vertebroplasty or percutaneous kyphoplasty can provide significant pain relief and improve mobility. However, studies have reported both the recurrence of vertebral compression fractures at the index level after vertebroplasty and the development of new vertebral fractures at the adjacent level that occur without any additional trauma. Pedicle screw fixation combined with percutaneous vertebroplasty has been proposed as an effective procedure for addressing osteoporotic thoracolumbar fractures. However, in osteoporotic populations, pedicle screws can loosen, pullout, or migrate. Currently, the efficacy of cortical bone trajectory screw fixation for osteoporotic fractures remains unclear. Thus, we assessed the effects of using cortical bone trajectory instrumentation with vertebroplasty on patient outcomes. Method: We retrospectively reviewed data from 12 consecutively sampled osteoporotic thoracolumbar fracture patients who underwent cortical bone trajectory instrumentation with vertebroplasty. Patients were enrolled beginning in October 2015 and were followed for >24 months. Result: The average age was 74 years, and the average dual-energy x-ray absorptiometry T-score was −3.6. The average visual analog scale pain scores improved from 8 to 2.5 after surgery. The average blood loss was 36.25 mL. All patients regained ambulation and experienced reduced pain post-surgery. No recurrent fractures or instrument failures were recorded during follow-up. Conclusions: Our findings suggest that cortical bone trajectory instrumentation combined with percutaneous vertebroplasty may be a good option for treating osteoporotic thoracolumbar fractures, as it can prevent recurrent vertebral fractures or related kyphosis in sagittal alignment. |
format | Online Article Text |
id | pubmed-7074157 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-70741572020-03-19 Cortical Bone Trajectory Instrumentation with Vertebroplasty for Osteoporotic Thoracolumbar Compression Fracture Hsu, Wei-Lin Lin, Yu-Hsiang Chuang, Hao-Yu Lee, Han-Chung Chen, Der-Cherng Chu, Yen-Tse Cho, Der-Yang Chen, Chao-Hsuan Medicina (Kaunas) Article Background: Osteoporotic spinal fractures commonly occur in elderly patients with low bone mineral density. In these cases, percutaneous vertebroplasty or percutaneous kyphoplasty can provide significant pain relief and improve mobility. However, studies have reported both the recurrence of vertebral compression fractures at the index level after vertebroplasty and the development of new vertebral fractures at the adjacent level that occur without any additional trauma. Pedicle screw fixation combined with percutaneous vertebroplasty has been proposed as an effective procedure for addressing osteoporotic thoracolumbar fractures. However, in osteoporotic populations, pedicle screws can loosen, pullout, or migrate. Currently, the efficacy of cortical bone trajectory screw fixation for osteoporotic fractures remains unclear. Thus, we assessed the effects of using cortical bone trajectory instrumentation with vertebroplasty on patient outcomes. Method: We retrospectively reviewed data from 12 consecutively sampled osteoporotic thoracolumbar fracture patients who underwent cortical bone trajectory instrumentation with vertebroplasty. Patients were enrolled beginning in October 2015 and were followed for >24 months. Result: The average age was 74 years, and the average dual-energy x-ray absorptiometry T-score was −3.6. The average visual analog scale pain scores improved from 8 to 2.5 after surgery. The average blood loss was 36.25 mL. All patients regained ambulation and experienced reduced pain post-surgery. No recurrent fractures or instrument failures were recorded during follow-up. Conclusions: Our findings suggest that cortical bone trajectory instrumentation combined with percutaneous vertebroplasty may be a good option for treating osteoporotic thoracolumbar fractures, as it can prevent recurrent vertebral fractures or related kyphosis in sagittal alignment. MDPI 2020-02-17 /pmc/articles/PMC7074157/ /pubmed/32079310 http://dx.doi.org/10.3390/medicina56020082 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Hsu, Wei-Lin Lin, Yu-Hsiang Chuang, Hao-Yu Lee, Han-Chung Chen, Der-Cherng Chu, Yen-Tse Cho, Der-Yang Chen, Chao-Hsuan Cortical Bone Trajectory Instrumentation with Vertebroplasty for Osteoporotic Thoracolumbar Compression Fracture |
title | Cortical Bone Trajectory Instrumentation with Vertebroplasty for Osteoporotic Thoracolumbar Compression Fracture |
title_full | Cortical Bone Trajectory Instrumentation with Vertebroplasty for Osteoporotic Thoracolumbar Compression Fracture |
title_fullStr | Cortical Bone Trajectory Instrumentation with Vertebroplasty for Osteoporotic Thoracolumbar Compression Fracture |
title_full_unstemmed | Cortical Bone Trajectory Instrumentation with Vertebroplasty for Osteoporotic Thoracolumbar Compression Fracture |
title_short | Cortical Bone Trajectory Instrumentation with Vertebroplasty for Osteoporotic Thoracolumbar Compression Fracture |
title_sort | cortical bone trajectory instrumentation with vertebroplasty for osteoporotic thoracolumbar compression fracture |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7074157/ https://www.ncbi.nlm.nih.gov/pubmed/32079310 http://dx.doi.org/10.3390/medicina56020082 |
work_keys_str_mv | AT hsuweilin corticalbonetrajectoryinstrumentationwithvertebroplastyforosteoporoticthoracolumbarcompressionfracture AT linyuhsiang corticalbonetrajectoryinstrumentationwithvertebroplastyforosteoporoticthoracolumbarcompressionfracture AT chuanghaoyu corticalbonetrajectoryinstrumentationwithvertebroplastyforosteoporoticthoracolumbarcompressionfracture AT leehanchung corticalbonetrajectoryinstrumentationwithvertebroplastyforosteoporoticthoracolumbarcompressionfracture AT chendercherng corticalbonetrajectoryinstrumentationwithvertebroplastyforosteoporoticthoracolumbarcompressionfracture AT chuyentse corticalbonetrajectoryinstrumentationwithvertebroplastyforosteoporoticthoracolumbarcompressionfracture AT choderyang corticalbonetrajectoryinstrumentationwithvertebroplastyforosteoporoticthoracolumbarcompressionfracture AT chenchaohsuan corticalbonetrajectoryinstrumentationwithvertebroplastyforosteoporoticthoracolumbarcompressionfracture |