Cargando…

An LED-Driven AuNPs-PDMS Microfluidic Chip and Integrated Device for the Detection of Digital Loop-Mediated Isothermal DNA Amplification

The sensitive quantification of low-abundance nucleic acids holds importance for a range of clinical applications and biological studies. In this study, we describe a facile microfluidic chip for absolute DNA quantifications based on the digital loop-mediated isothermal amplification (digital LAMP)...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Zengming, Zhao, Shuhao, Hu, Fei, Yang, Guangpu, Li, Juan, Tian, Hui, Peng, Niancai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7074644/
https://www.ncbi.nlm.nih.gov/pubmed/32046315
http://dx.doi.org/10.3390/mi11020177
_version_ 1783506880747798528
author Zhang, Zengming
Zhao, Shuhao
Hu, Fei
Yang, Guangpu
Li, Juan
Tian, Hui
Peng, Niancai
author_facet Zhang, Zengming
Zhao, Shuhao
Hu, Fei
Yang, Guangpu
Li, Juan
Tian, Hui
Peng, Niancai
author_sort Zhang, Zengming
collection PubMed
description The sensitive quantification of low-abundance nucleic acids holds importance for a range of clinical applications and biological studies. In this study, we describe a facile microfluidic chip for absolute DNA quantifications based on the digital loop-mediated isothermal amplification (digital LAMP) method. This microfluidic chip integrates a cross-flow channel for droplet generation with a micro-cavity for droplet tiling. DNA templates in the LAMP reagent were divided into ~20,000 water-in-oil droplets at the cross-flow channel. The droplets were then tiled in the micro-cavity for isothermal amplification and fluorescent detection. Different from the existing polydimethylsiloxane (PDMS) microfluidic chips, this study incorporates gold nanoparticles (AuNPs) into PDMS substrate through silica coating and dodecanol modification. The digital LAMP chip prepared by AuNPs-PDMS combines the benefits of the microstructure manufacturing performance of PDMS with the light-to-heat conversion advantages of AuNPs. Upon illumination with a near infrared (NIR) LED, the droplets were stably and efficiently heated by the AuNPs in PDMS. We further introduce an integrated device with a NIR heating unit and a fluorescent detection unit. The system could detect HBV (hepatitis B virus)-DNA at a concentration of 1 × 10(1) to 1 × 10(4) copies/μL. The LED-driven digital LAMP chip and the integrated device; therefore, demonstrate high accuracy and excellent performance for the absolute quantification of low-abundance nucleic acids, showing the advantages of integration, miniaturization, cost, and power consumption.
format Online
Article
Text
id pubmed-7074644
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-70746442020-03-20 An LED-Driven AuNPs-PDMS Microfluidic Chip and Integrated Device for the Detection of Digital Loop-Mediated Isothermal DNA Amplification Zhang, Zengming Zhao, Shuhao Hu, Fei Yang, Guangpu Li, Juan Tian, Hui Peng, Niancai Micromachines (Basel) Article The sensitive quantification of low-abundance nucleic acids holds importance for a range of clinical applications and biological studies. In this study, we describe a facile microfluidic chip for absolute DNA quantifications based on the digital loop-mediated isothermal amplification (digital LAMP) method. This microfluidic chip integrates a cross-flow channel for droplet generation with a micro-cavity for droplet tiling. DNA templates in the LAMP reagent were divided into ~20,000 water-in-oil droplets at the cross-flow channel. The droplets were then tiled in the micro-cavity for isothermal amplification and fluorescent detection. Different from the existing polydimethylsiloxane (PDMS) microfluidic chips, this study incorporates gold nanoparticles (AuNPs) into PDMS substrate through silica coating and dodecanol modification. The digital LAMP chip prepared by AuNPs-PDMS combines the benefits of the microstructure manufacturing performance of PDMS with the light-to-heat conversion advantages of AuNPs. Upon illumination with a near infrared (NIR) LED, the droplets were stably and efficiently heated by the AuNPs in PDMS. We further introduce an integrated device with a NIR heating unit and a fluorescent detection unit. The system could detect HBV (hepatitis B virus)-DNA at a concentration of 1 × 10(1) to 1 × 10(4) copies/μL. The LED-driven digital LAMP chip and the integrated device; therefore, demonstrate high accuracy and excellent performance for the absolute quantification of low-abundance nucleic acids, showing the advantages of integration, miniaturization, cost, and power consumption. MDPI 2020-02-08 /pmc/articles/PMC7074644/ /pubmed/32046315 http://dx.doi.org/10.3390/mi11020177 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zhang, Zengming
Zhao, Shuhao
Hu, Fei
Yang, Guangpu
Li, Juan
Tian, Hui
Peng, Niancai
An LED-Driven AuNPs-PDMS Microfluidic Chip and Integrated Device for the Detection of Digital Loop-Mediated Isothermal DNA Amplification
title An LED-Driven AuNPs-PDMS Microfluidic Chip and Integrated Device for the Detection of Digital Loop-Mediated Isothermal DNA Amplification
title_full An LED-Driven AuNPs-PDMS Microfluidic Chip and Integrated Device for the Detection of Digital Loop-Mediated Isothermal DNA Amplification
title_fullStr An LED-Driven AuNPs-PDMS Microfluidic Chip and Integrated Device for the Detection of Digital Loop-Mediated Isothermal DNA Amplification
title_full_unstemmed An LED-Driven AuNPs-PDMS Microfluidic Chip and Integrated Device for the Detection of Digital Loop-Mediated Isothermal DNA Amplification
title_short An LED-Driven AuNPs-PDMS Microfluidic Chip and Integrated Device for the Detection of Digital Loop-Mediated Isothermal DNA Amplification
title_sort led-driven aunps-pdms microfluidic chip and integrated device for the detection of digital loop-mediated isothermal dna amplification
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7074644/
https://www.ncbi.nlm.nih.gov/pubmed/32046315
http://dx.doi.org/10.3390/mi11020177
work_keys_str_mv AT zhangzengming anleddrivenaunpspdmsmicrofluidicchipandintegrateddeviceforthedetectionofdigitalloopmediatedisothermaldnaamplification
AT zhaoshuhao anleddrivenaunpspdmsmicrofluidicchipandintegrateddeviceforthedetectionofdigitalloopmediatedisothermaldnaamplification
AT hufei anleddrivenaunpspdmsmicrofluidicchipandintegrateddeviceforthedetectionofdigitalloopmediatedisothermaldnaamplification
AT yangguangpu anleddrivenaunpspdmsmicrofluidicchipandintegrateddeviceforthedetectionofdigitalloopmediatedisothermaldnaamplification
AT lijuan anleddrivenaunpspdmsmicrofluidicchipandintegrateddeviceforthedetectionofdigitalloopmediatedisothermaldnaamplification
AT tianhui anleddrivenaunpspdmsmicrofluidicchipandintegrateddeviceforthedetectionofdigitalloopmediatedisothermaldnaamplification
AT pengniancai anleddrivenaunpspdmsmicrofluidicchipandintegrateddeviceforthedetectionofdigitalloopmediatedisothermaldnaamplification
AT zhangzengming leddrivenaunpspdmsmicrofluidicchipandintegrateddeviceforthedetectionofdigitalloopmediatedisothermaldnaamplification
AT zhaoshuhao leddrivenaunpspdmsmicrofluidicchipandintegrateddeviceforthedetectionofdigitalloopmediatedisothermaldnaamplification
AT hufei leddrivenaunpspdmsmicrofluidicchipandintegrateddeviceforthedetectionofdigitalloopmediatedisothermaldnaamplification
AT yangguangpu leddrivenaunpspdmsmicrofluidicchipandintegrateddeviceforthedetectionofdigitalloopmediatedisothermaldnaamplification
AT lijuan leddrivenaunpspdmsmicrofluidicchipandintegrateddeviceforthedetectionofdigitalloopmediatedisothermaldnaamplification
AT tianhui leddrivenaunpspdmsmicrofluidicchipandintegrateddeviceforthedetectionofdigitalloopmediatedisothermaldnaamplification
AT pengniancai leddrivenaunpspdmsmicrofluidicchipandintegrateddeviceforthedetectionofdigitalloopmediatedisothermaldnaamplification