Cargando…

Utilizing the TrueBeam Advanced Imaging Package to monitor intrafraction motion with periodic kV imaging and automatic marker detection during VMAT prostate treatments

BACKGROUND: Fiducial markers are frequently used before treatment for image‐guided patient setup in radiation therapy (RT), but can also be used during treatment for image‐guided intrafraction motion detection. This report describes our implementation of automatic marker detection with periodic kV i...

Descripción completa

Detalles Bibliográficos
Autores principales: Korpics, Mark C., Rokni, Michelle, Degnan, Michael, Aydogan, Bulent, Liauw, Stanley L., Redler, Gage
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7075383/
https://www.ncbi.nlm.nih.gov/pubmed/31981305
http://dx.doi.org/10.1002/acm2.12822
_version_ 1783507030873473024
author Korpics, Mark C.
Rokni, Michelle
Degnan, Michael
Aydogan, Bulent
Liauw, Stanley L.
Redler, Gage
author_facet Korpics, Mark C.
Rokni, Michelle
Degnan, Michael
Aydogan, Bulent
Liauw, Stanley L.
Redler, Gage
author_sort Korpics, Mark C.
collection PubMed
description BACKGROUND: Fiducial markers are frequently used before treatment for image‐guided patient setup in radiation therapy (RT), but can also be used during treatment for image‐guided intrafraction motion detection. This report describes our implementation of automatic marker detection with periodic kV imaging (TrueBeam v2.5) to monitor and correct intrafraction motion during prostate RT. METHODS: We evaluated the reproducibility and accuracy of software fiducial detection using a phantom with 3 implanted fiducial markers. Clinical implementation for patients with intraprostatic fiducials receiving volumetric modulated arc therapy (VMAT) utilized periodic on‐board kV imaging with 10 s intervals during treatment delivery. For each image, the software automatically identified fiducial locations and determined whether their distance relative to planned locations were within a 3 mm tolerance. Motion was corrected if either ≥2 fiducials in a single image or ≥1 fiducial in sequential images were out of tolerance. RESULTS: Phantom studies demonstrated poorer performance of linear fiducials compared to collapsible fiducials, and wide variability to accurately detect fiducials across eight software settings. For any given setting, results were relatively reproducible and precise to ~0.5 mm. Across 17 patients treated with a median of 20 fractions, the software recommended a shift in 44% of fractions, and a shift was actually implemented after visual confirmation of movement greater than the 3 mm threshold in 20% of fractions. Adjustment of our approach led to improved accuracy for the latter (n = 7) patient subset. On average, table repositioning added 3.0 ± 0.3 min to patient time on table. Periodic kV imaging increased skin dose by an estimated 1 cGy per treatment arc. CONCLUSIONS: Periodic kV imaging with automatic detection of motion during VMAT prostate treatments is commercially available, and can be successfully implemented to mitigate effects of intrafraction motion with careful attention to software settings.
format Online
Article
Text
id pubmed-7075383
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-70753832020-03-17 Utilizing the TrueBeam Advanced Imaging Package to monitor intrafraction motion with periodic kV imaging and automatic marker detection during VMAT prostate treatments Korpics, Mark C. Rokni, Michelle Degnan, Michael Aydogan, Bulent Liauw, Stanley L. Redler, Gage J Appl Clin Med Phys Technical Notes BACKGROUND: Fiducial markers are frequently used before treatment for image‐guided patient setup in radiation therapy (RT), but can also be used during treatment for image‐guided intrafraction motion detection. This report describes our implementation of automatic marker detection with periodic kV imaging (TrueBeam v2.5) to monitor and correct intrafraction motion during prostate RT. METHODS: We evaluated the reproducibility and accuracy of software fiducial detection using a phantom with 3 implanted fiducial markers. Clinical implementation for patients with intraprostatic fiducials receiving volumetric modulated arc therapy (VMAT) utilized periodic on‐board kV imaging with 10 s intervals during treatment delivery. For each image, the software automatically identified fiducial locations and determined whether their distance relative to planned locations were within a 3 mm tolerance. Motion was corrected if either ≥2 fiducials in a single image or ≥1 fiducial in sequential images were out of tolerance. RESULTS: Phantom studies demonstrated poorer performance of linear fiducials compared to collapsible fiducials, and wide variability to accurately detect fiducials across eight software settings. For any given setting, results were relatively reproducible and precise to ~0.5 mm. Across 17 patients treated with a median of 20 fractions, the software recommended a shift in 44% of fractions, and a shift was actually implemented after visual confirmation of movement greater than the 3 mm threshold in 20% of fractions. Adjustment of our approach led to improved accuracy for the latter (n = 7) patient subset. On average, table repositioning added 3.0 ± 0.3 min to patient time on table. Periodic kV imaging increased skin dose by an estimated 1 cGy per treatment arc. CONCLUSIONS: Periodic kV imaging with automatic detection of motion during VMAT prostate treatments is commercially available, and can be successfully implemented to mitigate effects of intrafraction motion with careful attention to software settings. John Wiley and Sons Inc. 2020-01-24 /pmc/articles/PMC7075383/ /pubmed/31981305 http://dx.doi.org/10.1002/acm2.12822 Text en © 2020 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Notes
Korpics, Mark C.
Rokni, Michelle
Degnan, Michael
Aydogan, Bulent
Liauw, Stanley L.
Redler, Gage
Utilizing the TrueBeam Advanced Imaging Package to monitor intrafraction motion with periodic kV imaging and automatic marker detection during VMAT prostate treatments
title Utilizing the TrueBeam Advanced Imaging Package to monitor intrafraction motion with periodic kV imaging and automatic marker detection during VMAT prostate treatments
title_full Utilizing the TrueBeam Advanced Imaging Package to monitor intrafraction motion with periodic kV imaging and automatic marker detection during VMAT prostate treatments
title_fullStr Utilizing the TrueBeam Advanced Imaging Package to monitor intrafraction motion with periodic kV imaging and automatic marker detection during VMAT prostate treatments
title_full_unstemmed Utilizing the TrueBeam Advanced Imaging Package to monitor intrafraction motion with periodic kV imaging and automatic marker detection during VMAT prostate treatments
title_short Utilizing the TrueBeam Advanced Imaging Package to monitor intrafraction motion with periodic kV imaging and automatic marker detection during VMAT prostate treatments
title_sort utilizing the truebeam advanced imaging package to monitor intrafraction motion with periodic kv imaging and automatic marker detection during vmat prostate treatments
topic Technical Notes
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7075383/
https://www.ncbi.nlm.nih.gov/pubmed/31981305
http://dx.doi.org/10.1002/acm2.12822
work_keys_str_mv AT korpicsmarkc utilizingthetruebeamadvancedimagingpackagetomonitorintrafractionmotionwithperiodickvimagingandautomaticmarkerdetectionduringvmatprostatetreatments
AT roknimichelle utilizingthetruebeamadvancedimagingpackagetomonitorintrafractionmotionwithperiodickvimagingandautomaticmarkerdetectionduringvmatprostatetreatments
AT degnanmichael utilizingthetruebeamadvancedimagingpackagetomonitorintrafractionmotionwithperiodickvimagingandautomaticmarkerdetectionduringvmatprostatetreatments
AT aydoganbulent utilizingthetruebeamadvancedimagingpackagetomonitorintrafractionmotionwithperiodickvimagingandautomaticmarkerdetectionduringvmatprostatetreatments
AT liauwstanleyl utilizingthetruebeamadvancedimagingpackagetomonitorintrafractionmotionwithperiodickvimagingandautomaticmarkerdetectionduringvmatprostatetreatments
AT redlergage utilizingthetruebeamadvancedimagingpackagetomonitorintrafractionmotionwithperiodickvimagingandautomaticmarkerdetectionduringvmatprostatetreatments