Cargando…

Comparative analysis of novel MGISEQ-2000 sequencing platform vs Illumina HiSeq 2500 for whole-genome sequencing

The MGISEQ-2000 developed by MGI Tech Co. Ltd. (a subsidiary of the BGI Group) is a new competitor of such next-generation sequencing platforms as NovaSeq and HiSeq (Illumina). Its sequencing principle is based on the DNB and the cPAS technologies, which were also used in the previous version of the...

Descripción completa

Detalles Bibliográficos
Autores principales: Korostin, Dmitriy, Kulemin, Nikolay, Naumov, Vladimir, Belova, Vera, Kwon, Dmitriy, Gorbachev, Alexey
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7075590/
https://www.ncbi.nlm.nih.gov/pubmed/32176719
http://dx.doi.org/10.1371/journal.pone.0230301
_version_ 1783507061894545408
author Korostin, Dmitriy
Kulemin, Nikolay
Naumov, Vladimir
Belova, Vera
Kwon, Dmitriy
Gorbachev, Alexey
author_facet Korostin, Dmitriy
Kulemin, Nikolay
Naumov, Vladimir
Belova, Vera
Kwon, Dmitriy
Gorbachev, Alexey
author_sort Korostin, Dmitriy
collection PubMed
description The MGISEQ-2000 developed by MGI Tech Co. Ltd. (a subsidiary of the BGI Group) is a new competitor of such next-generation sequencing platforms as NovaSeq and HiSeq (Illumina). Its sequencing principle is based on the DNB and the cPAS technologies, which were also used in the previous version of the BGISEQ-500 device. However, the reagents for MGISEQ-2000 have been refined and the platform utilizes updated software. The cPAS method is an advanced technology based on the cPAL previously created by Complete Genomics. In this paper, the authors compare the results of the whole-genome sequencing of a DNA sample from a Russian female donor performed on MGISEQ-2000 and Illumina HiSeq 2500 (both PE150). Two platforms were compared in terms of sequencing quality, number of errors and performance. Additionally, we performed variant calling using four different software packages: Samtools mpileaup, Strelka2, Sentieon, and GATK. The accuracy of SNP detection was similar in the data generated by MGISEQ-2000 and HiSeq 2500, which was used as a reference. At the same time, a separate indel analysis of the overall error rate revealed similar FPR values and lower sensitivity. It may be concluded with confidence that the data generated by the analyzed sequencing systems is characterized by comparable magnitudes of error and that MGISEQ-2000 and HiSeq 2500 can be used interchangeably for similar tasks like whole genome sequencing.
format Online
Article
Text
id pubmed-7075590
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-70755902020-03-23 Comparative analysis of novel MGISEQ-2000 sequencing platform vs Illumina HiSeq 2500 for whole-genome sequencing Korostin, Dmitriy Kulemin, Nikolay Naumov, Vladimir Belova, Vera Kwon, Dmitriy Gorbachev, Alexey PLoS One Research Article The MGISEQ-2000 developed by MGI Tech Co. Ltd. (a subsidiary of the BGI Group) is a new competitor of such next-generation sequencing platforms as NovaSeq and HiSeq (Illumina). Its sequencing principle is based on the DNB and the cPAS technologies, which were also used in the previous version of the BGISEQ-500 device. However, the reagents for MGISEQ-2000 have been refined and the platform utilizes updated software. The cPAS method is an advanced technology based on the cPAL previously created by Complete Genomics. In this paper, the authors compare the results of the whole-genome sequencing of a DNA sample from a Russian female donor performed on MGISEQ-2000 and Illumina HiSeq 2500 (both PE150). Two platforms were compared in terms of sequencing quality, number of errors and performance. Additionally, we performed variant calling using four different software packages: Samtools mpileaup, Strelka2, Sentieon, and GATK. The accuracy of SNP detection was similar in the data generated by MGISEQ-2000 and HiSeq 2500, which was used as a reference. At the same time, a separate indel analysis of the overall error rate revealed similar FPR values and lower sensitivity. It may be concluded with confidence that the data generated by the analyzed sequencing systems is characterized by comparable magnitudes of error and that MGISEQ-2000 and HiSeq 2500 can be used interchangeably for similar tasks like whole genome sequencing. Public Library of Science 2020-03-16 /pmc/articles/PMC7075590/ /pubmed/32176719 http://dx.doi.org/10.1371/journal.pone.0230301 Text en © 2020 Korostin et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Korostin, Dmitriy
Kulemin, Nikolay
Naumov, Vladimir
Belova, Vera
Kwon, Dmitriy
Gorbachev, Alexey
Comparative analysis of novel MGISEQ-2000 sequencing platform vs Illumina HiSeq 2500 for whole-genome sequencing
title Comparative analysis of novel MGISEQ-2000 sequencing platform vs Illumina HiSeq 2500 for whole-genome sequencing
title_full Comparative analysis of novel MGISEQ-2000 sequencing platform vs Illumina HiSeq 2500 for whole-genome sequencing
title_fullStr Comparative analysis of novel MGISEQ-2000 sequencing platform vs Illumina HiSeq 2500 for whole-genome sequencing
title_full_unstemmed Comparative analysis of novel MGISEQ-2000 sequencing platform vs Illumina HiSeq 2500 for whole-genome sequencing
title_short Comparative analysis of novel MGISEQ-2000 sequencing platform vs Illumina HiSeq 2500 for whole-genome sequencing
title_sort comparative analysis of novel mgiseq-2000 sequencing platform vs illumina hiseq 2500 for whole-genome sequencing
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7075590/
https://www.ncbi.nlm.nih.gov/pubmed/32176719
http://dx.doi.org/10.1371/journal.pone.0230301
work_keys_str_mv AT korostindmitriy comparativeanalysisofnovelmgiseq2000sequencingplatformvsilluminahiseq2500forwholegenomesequencing
AT kuleminnikolay comparativeanalysisofnovelmgiseq2000sequencingplatformvsilluminahiseq2500forwholegenomesequencing
AT naumovvladimir comparativeanalysisofnovelmgiseq2000sequencingplatformvsilluminahiseq2500forwholegenomesequencing
AT belovavera comparativeanalysisofnovelmgiseq2000sequencingplatformvsilluminahiseq2500forwholegenomesequencing
AT kwondmitriy comparativeanalysisofnovelmgiseq2000sequencingplatformvsilluminahiseq2500forwholegenomesequencing
AT gorbachevalexey comparativeanalysisofnovelmgiseq2000sequencingplatformvsilluminahiseq2500forwholegenomesequencing