The Reliability of Foot and Ankle Bone and Joint Kinematics Measured With Biplanar Videoradiography and Manual Scientific Rotoscoping
The intricate motion of the small bones of the feet are critical for its diverse function. Accurately measuring the 3-dimensional (3D) motion of these bones has attracted much attention over the years and until recently, was limited to invasive techniques or quantification of functional segments usi...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7075816/ https://www.ncbi.nlm.nih.gov/pubmed/32211386 http://dx.doi.org/10.3389/fbioe.2020.00106 |
_version_ | 1783507092002308096 |
---|---|
author | Maharaj, Jayishni N. Kessler, Sarah Rainbow, Michael J. D’Andrea, Susan E. Konow, Nicolai Kelly, Luke A. Lichtwark, Glen A. |
author_facet | Maharaj, Jayishni N. Kessler, Sarah Rainbow, Michael J. D’Andrea, Susan E. Konow, Nicolai Kelly, Luke A. Lichtwark, Glen A. |
author_sort | Maharaj, Jayishni N. |
collection | PubMed |
description | The intricate motion of the small bones of the feet are critical for its diverse function. Accurately measuring the 3-dimensional (3D) motion of these bones has attracted much attention over the years and until recently, was limited to invasive techniques or quantification of functional segments using multi-segment foot models. Biplanar videoradiography and model-based scientific rotoscoping offers an exciting alternative that allows us to focus on the intricate motion of individual bones in the foot. However, scientific rotoscoping, the process of rotating and translating a 3D bone model so that it aligns with the captured x-ray images, is either semi- or completely manual and it is unknown how much human error affects tracking results. Thus, the aim of this study was to quantify the inter- and intra-operator reliability of manually rotoscoping in vivo bone motion of the tibia, talus, and calcaneus during running. Three-dimensional CT bone volumes and high-speed biplanar videoradiography images of the foot were acquired on six participants. The six-degree-of-freedom motions of the tibia, talus, and calcaneus were determined using a manual markerless registration algorithm. Two operators performed the tracking, and additionally, the first operator re-tracked all bones, to test for intra-operator effects. Mean RMS errors were 1.86 mm and 1.90° for intra-operator comparisons and 2.30 mm and 2.60° for inter-operator comparisons across all bones and planes. The moderate to strong similarity values indicate that tracking bones and joint kinematics between sessions and operators is reliable for running. These errors are likely acceptable for defining gross joint angles. However, this magnitude of error may limit the capacity to perform advanced analyses of joint interactions, particularly those that require precise (sub-millimeter) estimates of bone position and orientation. Optimizing the view and image quality of the biplanar videoradiography system as well as the automated tracking algorithms for rotoscoping bones in the foot are required to reduce these errors and the time burden associated with the manual processing. |
format | Online Article Text |
id | pubmed-7075816 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-70758162020-03-24 The Reliability of Foot and Ankle Bone and Joint Kinematics Measured With Biplanar Videoradiography and Manual Scientific Rotoscoping Maharaj, Jayishni N. Kessler, Sarah Rainbow, Michael J. D’Andrea, Susan E. Konow, Nicolai Kelly, Luke A. Lichtwark, Glen A. Front Bioeng Biotechnol Bioengineering and Biotechnology The intricate motion of the small bones of the feet are critical for its diverse function. Accurately measuring the 3-dimensional (3D) motion of these bones has attracted much attention over the years and until recently, was limited to invasive techniques or quantification of functional segments using multi-segment foot models. Biplanar videoradiography and model-based scientific rotoscoping offers an exciting alternative that allows us to focus on the intricate motion of individual bones in the foot. However, scientific rotoscoping, the process of rotating and translating a 3D bone model so that it aligns with the captured x-ray images, is either semi- or completely manual and it is unknown how much human error affects tracking results. Thus, the aim of this study was to quantify the inter- and intra-operator reliability of manually rotoscoping in vivo bone motion of the tibia, talus, and calcaneus during running. Three-dimensional CT bone volumes and high-speed biplanar videoradiography images of the foot were acquired on six participants. The six-degree-of-freedom motions of the tibia, talus, and calcaneus were determined using a manual markerless registration algorithm. Two operators performed the tracking, and additionally, the first operator re-tracked all bones, to test for intra-operator effects. Mean RMS errors were 1.86 mm and 1.90° for intra-operator comparisons and 2.30 mm and 2.60° for inter-operator comparisons across all bones and planes. The moderate to strong similarity values indicate that tracking bones and joint kinematics between sessions and operators is reliable for running. These errors are likely acceptable for defining gross joint angles. However, this magnitude of error may limit the capacity to perform advanced analyses of joint interactions, particularly those that require precise (sub-millimeter) estimates of bone position and orientation. Optimizing the view and image quality of the biplanar videoradiography system as well as the automated tracking algorithms for rotoscoping bones in the foot are required to reduce these errors and the time burden associated with the manual processing. Frontiers Media S.A. 2020-03-10 /pmc/articles/PMC7075816/ /pubmed/32211386 http://dx.doi.org/10.3389/fbioe.2020.00106 Text en Copyright © 2020 Maharaj, Kessler, Rainbow, D’Andrea, Konow, Kelly and Lichtwark. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Bioengineering and Biotechnology Maharaj, Jayishni N. Kessler, Sarah Rainbow, Michael J. D’Andrea, Susan E. Konow, Nicolai Kelly, Luke A. Lichtwark, Glen A. The Reliability of Foot and Ankle Bone and Joint Kinematics Measured With Biplanar Videoradiography and Manual Scientific Rotoscoping |
title | The Reliability of Foot and Ankle Bone and Joint Kinematics Measured With Biplanar Videoradiography and Manual Scientific Rotoscoping |
title_full | The Reliability of Foot and Ankle Bone and Joint Kinematics Measured With Biplanar Videoradiography and Manual Scientific Rotoscoping |
title_fullStr | The Reliability of Foot and Ankle Bone and Joint Kinematics Measured With Biplanar Videoradiography and Manual Scientific Rotoscoping |
title_full_unstemmed | The Reliability of Foot and Ankle Bone and Joint Kinematics Measured With Biplanar Videoradiography and Manual Scientific Rotoscoping |
title_short | The Reliability of Foot and Ankle Bone and Joint Kinematics Measured With Biplanar Videoradiography and Manual Scientific Rotoscoping |
title_sort | reliability of foot and ankle bone and joint kinematics measured with biplanar videoradiography and manual scientific rotoscoping |
topic | Bioengineering and Biotechnology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7075816/ https://www.ncbi.nlm.nih.gov/pubmed/32211386 http://dx.doi.org/10.3389/fbioe.2020.00106 |
work_keys_str_mv | AT maharajjayishnin thereliabilityoffootandankleboneandjointkinematicsmeasuredwithbiplanarvideoradiographyandmanualscientificrotoscoping AT kesslersarah thereliabilityoffootandankleboneandjointkinematicsmeasuredwithbiplanarvideoradiographyandmanualscientificrotoscoping AT rainbowmichaelj thereliabilityoffootandankleboneandjointkinematicsmeasuredwithbiplanarvideoradiographyandmanualscientificrotoscoping AT dandreasusane thereliabilityoffootandankleboneandjointkinematicsmeasuredwithbiplanarvideoradiographyandmanualscientificrotoscoping AT konownicolai thereliabilityoffootandankleboneandjointkinematicsmeasuredwithbiplanarvideoradiographyandmanualscientificrotoscoping AT kellylukea thereliabilityoffootandankleboneandjointkinematicsmeasuredwithbiplanarvideoradiographyandmanualscientificrotoscoping AT lichtwarkglena thereliabilityoffootandankleboneandjointkinematicsmeasuredwithbiplanarvideoradiographyandmanualscientificrotoscoping AT maharajjayishnin reliabilityoffootandankleboneandjointkinematicsmeasuredwithbiplanarvideoradiographyandmanualscientificrotoscoping AT kesslersarah reliabilityoffootandankleboneandjointkinematicsmeasuredwithbiplanarvideoradiographyandmanualscientificrotoscoping AT rainbowmichaelj reliabilityoffootandankleboneandjointkinematicsmeasuredwithbiplanarvideoradiographyandmanualscientificrotoscoping AT dandreasusane reliabilityoffootandankleboneandjointkinematicsmeasuredwithbiplanarvideoradiographyandmanualscientificrotoscoping AT konownicolai reliabilityoffootandankleboneandjointkinematicsmeasuredwithbiplanarvideoradiographyandmanualscientificrotoscoping AT kellylukea reliabilityoffootandankleboneandjointkinematicsmeasuredwithbiplanarvideoradiographyandmanualscientificrotoscoping AT lichtwarkglena reliabilityoffootandankleboneandjointkinematicsmeasuredwithbiplanarvideoradiographyandmanualscientificrotoscoping |