Cargando…
PulseCam: a camera-based, motion-robust and highly sensitive blood perfusion imaging modality
Blood carries oxygen and nutrients to the trillions of cells in our body to sustain vital life processes. Lack of blood perfusion can cause irreversible cell damage. Therefore, blood perfusion measurement has widespread clinical applications. In this paper, we develop PulseCam — a new camera-based,...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7075982/ https://www.ncbi.nlm.nih.gov/pubmed/32179806 http://dx.doi.org/10.1038/s41598-020-61576-0 |
_version_ | 1783507128820957184 |
---|---|
author | Kumar, Mayank Suliburk, James W. Veeraraghavan, Ashok Sabharwal, Ashutosh |
author_facet | Kumar, Mayank Suliburk, James W. Veeraraghavan, Ashok Sabharwal, Ashutosh |
author_sort | Kumar, Mayank |
collection | PubMed |
description | Blood carries oxygen and nutrients to the trillions of cells in our body to sustain vital life processes. Lack of blood perfusion can cause irreversible cell damage. Therefore, blood perfusion measurement has widespread clinical applications. In this paper, we develop PulseCam — a new camera-based, motion-robust, and highly sensitive blood perfusion imaging modality with 1 mm spatial resolution and 1 frame-per-second temporal resolution. Existing camera-only blood perfusion imaging modality suffers from two core challenges: (i) motion artifact, and (ii) small signal recovery in the presence of large surface reflection and measurement noise. PulseCam addresses these challenges by robustly combining the video recording from the camera with a pulse waveform measured using a conventional pulse oximeter to obtain reliable blood perfusion maps in the presence of motion artifacts and outliers in the video recordings. For video stabilization, we adopt a novel brightness-invariant optical flow algorithm that helps us reduce error in blood perfusion estimate below 10% in different motion scenarios compared to 20–30% error when using current approaches. PulseCam can detect subtle changes in blood perfusion below the skin with at least two times better sensitivity, three times better response time, and is significantly cheaper compared to infrared thermography. PulseCam can also detect venous or partial blood flow occlusion that is difficult to identify using existing modalities such as the perfusion index measured using a pulse oximeter. With the help of a pilot clinical study, we also demonstrate that PulseCam is robust and reliable in an operationally challenging surgery room setting. We anticipate that PulseCam will be used both at the bedside as well as a point-of-care blood perfusion imaging device to visualize and analyze blood perfusion in an easy-to-use and cost-effective manner. |
format | Online Article Text |
id | pubmed-7075982 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-70759822020-03-23 PulseCam: a camera-based, motion-robust and highly sensitive blood perfusion imaging modality Kumar, Mayank Suliburk, James W. Veeraraghavan, Ashok Sabharwal, Ashutosh Sci Rep Article Blood carries oxygen and nutrients to the trillions of cells in our body to sustain vital life processes. Lack of blood perfusion can cause irreversible cell damage. Therefore, blood perfusion measurement has widespread clinical applications. In this paper, we develop PulseCam — a new camera-based, motion-robust, and highly sensitive blood perfusion imaging modality with 1 mm spatial resolution and 1 frame-per-second temporal resolution. Existing camera-only blood perfusion imaging modality suffers from two core challenges: (i) motion artifact, and (ii) small signal recovery in the presence of large surface reflection and measurement noise. PulseCam addresses these challenges by robustly combining the video recording from the camera with a pulse waveform measured using a conventional pulse oximeter to obtain reliable blood perfusion maps in the presence of motion artifacts and outliers in the video recordings. For video stabilization, we adopt a novel brightness-invariant optical flow algorithm that helps us reduce error in blood perfusion estimate below 10% in different motion scenarios compared to 20–30% error when using current approaches. PulseCam can detect subtle changes in blood perfusion below the skin with at least two times better sensitivity, three times better response time, and is significantly cheaper compared to infrared thermography. PulseCam can also detect venous or partial blood flow occlusion that is difficult to identify using existing modalities such as the perfusion index measured using a pulse oximeter. With the help of a pilot clinical study, we also demonstrate that PulseCam is robust and reliable in an operationally challenging surgery room setting. We anticipate that PulseCam will be used both at the bedside as well as a point-of-care blood perfusion imaging device to visualize and analyze blood perfusion in an easy-to-use and cost-effective manner. Nature Publishing Group UK 2020-03-16 /pmc/articles/PMC7075982/ /pubmed/32179806 http://dx.doi.org/10.1038/s41598-020-61576-0 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Kumar, Mayank Suliburk, James W. Veeraraghavan, Ashok Sabharwal, Ashutosh PulseCam: a camera-based, motion-robust and highly sensitive blood perfusion imaging modality |
title | PulseCam: a camera-based, motion-robust and highly sensitive blood perfusion imaging modality |
title_full | PulseCam: a camera-based, motion-robust and highly sensitive blood perfusion imaging modality |
title_fullStr | PulseCam: a camera-based, motion-robust and highly sensitive blood perfusion imaging modality |
title_full_unstemmed | PulseCam: a camera-based, motion-robust and highly sensitive blood perfusion imaging modality |
title_short | PulseCam: a camera-based, motion-robust and highly sensitive blood perfusion imaging modality |
title_sort | pulsecam: a camera-based, motion-robust and highly sensitive blood perfusion imaging modality |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7075982/ https://www.ncbi.nlm.nih.gov/pubmed/32179806 http://dx.doi.org/10.1038/s41598-020-61576-0 |
work_keys_str_mv | AT kumarmayank pulsecamacamerabasedmotionrobustandhighlysensitivebloodperfusionimagingmodality AT suliburkjamesw pulsecamacamerabasedmotionrobustandhighlysensitivebloodperfusionimagingmodality AT veeraraghavanashok pulsecamacamerabasedmotionrobustandhighlysensitivebloodperfusionimagingmodality AT sabharwalashutosh pulsecamacamerabasedmotionrobustandhighlysensitivebloodperfusionimagingmodality |