Cargando…

A Lateral Flow Strip Based on a Truncated Aptamer-Complementary Strand for Detection of Type-B Aflatoxins in Nuts and Dried Figs

Type-B aflatoxins (AFB(1) and AFB(2)) frequently contaminate food, especially nuts and fried figs, and seriously threaten human health; hence, it is necessary for the newly rapid and sensitive detection methods to prevent the consumption of potentially contaminated food. Here, a lateral flow aptasen...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhao, Zhilei, Wang, He, Zhai, Wenlei, Feng, Xiaoyuan, Fan, Xia, Chen, Ailiang, Wang, Meng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7076875/
https://www.ncbi.nlm.nih.gov/pubmed/32098355
http://dx.doi.org/10.3390/toxins12020136
_version_ 1783507306370039808
author Zhao, Zhilei
Wang, He
Zhai, Wenlei
Feng, Xiaoyuan
Fan, Xia
Chen, Ailiang
Wang, Meng
author_facet Zhao, Zhilei
Wang, He
Zhai, Wenlei
Feng, Xiaoyuan
Fan, Xia
Chen, Ailiang
Wang, Meng
author_sort Zhao, Zhilei
collection PubMed
description Type-B aflatoxins (AFB(1) and AFB(2)) frequently contaminate food, especially nuts and fried figs, and seriously threaten human health; hence, it is necessary for the newly rapid and sensitive detection methods to prevent the consumption of potentially contaminated food. Here, a lateral flow aptasensor for the detection of type-B aflatoxins was developed. It is based on the use of fluorescent dye Cy5 as a label for the aptamer, and on the competition between type-B aflatoxins and the complementary DNA of the aptamer. This is the first time that the complementary strand of the aptamer has been used as the test line (T-line) to detect type-B aflatoxins. In addition, the truncated aptamer was used to improve the affinity with type-B aflatoxins in our study. Therefore, the lengths of aptamer and cDNA probe were optimized as key parameters for higher sensitivity. In addition, binding buffer and organic solvent were investigated. The results showed that the best pair for achieving improved sensitivity and accuracy in detecting AFB(1) was formed by a shorter aptamer (32 bases) coupled with the probe complementary to the AFB(1) binding region of the aptamer. Under the optimal experimental conditions, the test strip showed an excellent linear relationship in the range from 0.2 to 20 ng/mL with a limit of detection of 0.16 ng/mL. This aptamer-based strip was successfully applied to the determination of type-B aflatoxins in spiked and commercial peanuts, almonds, and dried figs, and the recoveries of the spiked samples were from 93.3%−112.0%. The aptamer-complementary strand-based lateral flow test strip is a potential alternative tool for the rapid and sensitive detection of type-B aflatoxins in nuts and dried figs. It is of help for monitoring aflatoxins to avoid the consumption of unsafe food.
format Online
Article
Text
id pubmed-7076875
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-70768752020-03-20 A Lateral Flow Strip Based on a Truncated Aptamer-Complementary Strand for Detection of Type-B Aflatoxins in Nuts and Dried Figs Zhao, Zhilei Wang, He Zhai, Wenlei Feng, Xiaoyuan Fan, Xia Chen, Ailiang Wang, Meng Toxins (Basel) Article Type-B aflatoxins (AFB(1) and AFB(2)) frequently contaminate food, especially nuts and fried figs, and seriously threaten human health; hence, it is necessary for the newly rapid and sensitive detection methods to prevent the consumption of potentially contaminated food. Here, a lateral flow aptasensor for the detection of type-B aflatoxins was developed. It is based on the use of fluorescent dye Cy5 as a label for the aptamer, and on the competition between type-B aflatoxins and the complementary DNA of the aptamer. This is the first time that the complementary strand of the aptamer has been used as the test line (T-line) to detect type-B aflatoxins. In addition, the truncated aptamer was used to improve the affinity with type-B aflatoxins in our study. Therefore, the lengths of aptamer and cDNA probe were optimized as key parameters for higher sensitivity. In addition, binding buffer and organic solvent were investigated. The results showed that the best pair for achieving improved sensitivity and accuracy in detecting AFB(1) was formed by a shorter aptamer (32 bases) coupled with the probe complementary to the AFB(1) binding region of the aptamer. Under the optimal experimental conditions, the test strip showed an excellent linear relationship in the range from 0.2 to 20 ng/mL with a limit of detection of 0.16 ng/mL. This aptamer-based strip was successfully applied to the determination of type-B aflatoxins in spiked and commercial peanuts, almonds, and dried figs, and the recoveries of the spiked samples were from 93.3%−112.0%. The aptamer-complementary strand-based lateral flow test strip is a potential alternative tool for the rapid and sensitive detection of type-B aflatoxins in nuts and dried figs. It is of help for monitoring aflatoxins to avoid the consumption of unsafe food. MDPI 2020-02-22 /pmc/articles/PMC7076875/ /pubmed/32098355 http://dx.doi.org/10.3390/toxins12020136 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zhao, Zhilei
Wang, He
Zhai, Wenlei
Feng, Xiaoyuan
Fan, Xia
Chen, Ailiang
Wang, Meng
A Lateral Flow Strip Based on a Truncated Aptamer-Complementary Strand for Detection of Type-B Aflatoxins in Nuts and Dried Figs
title A Lateral Flow Strip Based on a Truncated Aptamer-Complementary Strand for Detection of Type-B Aflatoxins in Nuts and Dried Figs
title_full A Lateral Flow Strip Based on a Truncated Aptamer-Complementary Strand for Detection of Type-B Aflatoxins in Nuts and Dried Figs
title_fullStr A Lateral Flow Strip Based on a Truncated Aptamer-Complementary Strand for Detection of Type-B Aflatoxins in Nuts and Dried Figs
title_full_unstemmed A Lateral Flow Strip Based on a Truncated Aptamer-Complementary Strand for Detection of Type-B Aflatoxins in Nuts and Dried Figs
title_short A Lateral Flow Strip Based on a Truncated Aptamer-Complementary Strand for Detection of Type-B Aflatoxins in Nuts and Dried Figs
title_sort lateral flow strip based on a truncated aptamer-complementary strand for detection of type-b aflatoxins in nuts and dried figs
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7076875/
https://www.ncbi.nlm.nih.gov/pubmed/32098355
http://dx.doi.org/10.3390/toxins12020136
work_keys_str_mv AT zhaozhilei alateralflowstripbasedonatruncatedaptamercomplementarystrandfordetectionoftypebaflatoxinsinnutsanddriedfigs
AT wanghe alateralflowstripbasedonatruncatedaptamercomplementarystrandfordetectionoftypebaflatoxinsinnutsanddriedfigs
AT zhaiwenlei alateralflowstripbasedonatruncatedaptamercomplementarystrandfordetectionoftypebaflatoxinsinnutsanddriedfigs
AT fengxiaoyuan alateralflowstripbasedonatruncatedaptamercomplementarystrandfordetectionoftypebaflatoxinsinnutsanddriedfigs
AT fanxia alateralflowstripbasedonatruncatedaptamercomplementarystrandfordetectionoftypebaflatoxinsinnutsanddriedfigs
AT chenailiang alateralflowstripbasedonatruncatedaptamercomplementarystrandfordetectionoftypebaflatoxinsinnutsanddriedfigs
AT wangmeng alateralflowstripbasedonatruncatedaptamercomplementarystrandfordetectionoftypebaflatoxinsinnutsanddriedfigs
AT zhaozhilei lateralflowstripbasedonatruncatedaptamercomplementarystrandfordetectionoftypebaflatoxinsinnutsanddriedfigs
AT wanghe lateralflowstripbasedonatruncatedaptamercomplementarystrandfordetectionoftypebaflatoxinsinnutsanddriedfigs
AT zhaiwenlei lateralflowstripbasedonatruncatedaptamercomplementarystrandfordetectionoftypebaflatoxinsinnutsanddriedfigs
AT fengxiaoyuan lateralflowstripbasedonatruncatedaptamercomplementarystrandfordetectionoftypebaflatoxinsinnutsanddriedfigs
AT fanxia lateralflowstripbasedonatruncatedaptamercomplementarystrandfordetectionoftypebaflatoxinsinnutsanddriedfigs
AT chenailiang lateralflowstripbasedonatruncatedaptamercomplementarystrandfordetectionoftypebaflatoxinsinnutsanddriedfigs
AT wangmeng lateralflowstripbasedonatruncatedaptamercomplementarystrandfordetectionoftypebaflatoxinsinnutsanddriedfigs