Cargando…
Quality Assessment of Virus-Like Particles at Single Particle Level: A Comparative Study
Virus-like particles (VLPs) have emerged as a powerful scaffold for antigen presentation and delivery strategies. Compared to single protein-based therapeutics, quality assessment requires a higher degree of refinement due to the structure of VLPs and their similar properties to extracellular vesicl...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7077327/ https://www.ncbi.nlm.nih.gov/pubmed/32079288 http://dx.doi.org/10.3390/v12020223 |
_version_ | 1783507407837593600 |
---|---|
author | González-Domínguez, Irene Puente-Massaguer, Eduard Cervera, Laura Gòdia, Francesc |
author_facet | González-Domínguez, Irene Puente-Massaguer, Eduard Cervera, Laura Gòdia, Francesc |
author_sort | González-Domínguez, Irene |
collection | PubMed |
description | Virus-like particles (VLPs) have emerged as a powerful scaffold for antigen presentation and delivery strategies. Compared to single protein-based therapeutics, quality assessment requires a higher degree of refinement due to the structure of VLPs and their similar properties to extracellular vesicles (EVs). Advances in the field of nanotechnology with single particle and high-resolution analysis techniques provide appealing approaches to VLP characterization. In this study, six different biophysical methods have been assessed for the characterization of HIV-1-based VLPs produced in mammalian and insect cell platforms. Sample preparation and equipment set-up were optimized for the six strategies evaluated. Electron Microscopy (EM) disclosed the presence of several types of EVs within VLP preparations and cryogenic transmission electron microscopy (cryo-TEM) resulted in the best technique to resolve the VLP ultrastructure. The use of super-resolution fluorescence microscopy (SRFM), nanoparticle tracking analysis (NTA) and flow virometry enabled the high throughput quantification of VLPs. Interestingly, differences in the determination of nanoparticle concentration were observed between techniques. Moreover, NTA and flow virometry allowed the quantification of both EVs and VLPs within the same experiment while analyzing particle size distribution (PSD), simultaneously. These results provide new insights into the use of different analytical tools to monitor the production of nanoparticle-based biologicals and their associated contaminants. |
format | Online Article Text |
id | pubmed-7077327 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-70773272020-03-20 Quality Assessment of Virus-Like Particles at Single Particle Level: A Comparative Study González-Domínguez, Irene Puente-Massaguer, Eduard Cervera, Laura Gòdia, Francesc Viruses Article Virus-like particles (VLPs) have emerged as a powerful scaffold for antigen presentation and delivery strategies. Compared to single protein-based therapeutics, quality assessment requires a higher degree of refinement due to the structure of VLPs and their similar properties to extracellular vesicles (EVs). Advances in the field of nanotechnology with single particle and high-resolution analysis techniques provide appealing approaches to VLP characterization. In this study, six different biophysical methods have been assessed for the characterization of HIV-1-based VLPs produced in mammalian and insect cell platforms. Sample preparation and equipment set-up were optimized for the six strategies evaluated. Electron Microscopy (EM) disclosed the presence of several types of EVs within VLP preparations and cryogenic transmission electron microscopy (cryo-TEM) resulted in the best technique to resolve the VLP ultrastructure. The use of super-resolution fluorescence microscopy (SRFM), nanoparticle tracking analysis (NTA) and flow virometry enabled the high throughput quantification of VLPs. Interestingly, differences in the determination of nanoparticle concentration were observed between techniques. Moreover, NTA and flow virometry allowed the quantification of both EVs and VLPs within the same experiment while analyzing particle size distribution (PSD), simultaneously. These results provide new insights into the use of different analytical tools to monitor the production of nanoparticle-based biologicals and their associated contaminants. MDPI 2020-02-17 /pmc/articles/PMC7077327/ /pubmed/32079288 http://dx.doi.org/10.3390/v12020223 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article González-Domínguez, Irene Puente-Massaguer, Eduard Cervera, Laura Gòdia, Francesc Quality Assessment of Virus-Like Particles at Single Particle Level: A Comparative Study |
title | Quality Assessment of Virus-Like Particles at Single Particle Level: A Comparative Study |
title_full | Quality Assessment of Virus-Like Particles at Single Particle Level: A Comparative Study |
title_fullStr | Quality Assessment of Virus-Like Particles at Single Particle Level: A Comparative Study |
title_full_unstemmed | Quality Assessment of Virus-Like Particles at Single Particle Level: A Comparative Study |
title_short | Quality Assessment of Virus-Like Particles at Single Particle Level: A Comparative Study |
title_sort | quality assessment of virus-like particles at single particle level: a comparative study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7077327/ https://www.ncbi.nlm.nih.gov/pubmed/32079288 http://dx.doi.org/10.3390/v12020223 |
work_keys_str_mv | AT gonzalezdominguezirene qualityassessmentofviruslikeparticlesatsingleparticlelevelacomparativestudy AT puentemassaguereduard qualityassessmentofviruslikeparticlesatsingleparticlelevelacomparativestudy AT cerveralaura qualityassessmentofviruslikeparticlesatsingleparticlelevelacomparativestudy AT godiafrancesc qualityassessmentofviruslikeparticlesatsingleparticlelevelacomparativestudy |