Ultra-Stable UiO-66 Involved Molecularly Imprinted Polymers for Specific and Sensitive Determination of Tyramine Based on Quartz Crystal Microbalance Technology

A rapid method was developed to determine the content of tyramine in food on the basis of the combination of molecular imprinting technique and the metal-organic frameworks. We developed the new molecular imprinted polymers based on metal-organic frameworks UiO-66 (named UiO-66@MIPs) as the sensing...

Descripción completa

Detalles Bibliográficos
Autores principales: Yao, Chi-Xuan, Zhao, Ning, Liu, Jing-Min, Fang, Guo-Zhen, Wang, Shuo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7077428/
https://www.ncbi.nlm.nih.gov/pubmed/32024028
http://dx.doi.org/10.3390/polym12020281
Descripción
Sumario:A rapid method was developed to determine the content of tyramine in food on the basis of the combination of molecular imprinting technique and the metal-organic frameworks. We developed the new molecular imprinted polymers based on metal-organic frameworks UiO-66 (named UiO-66@MIPs) as the sensing recognition element, the non-molecular imprinted polymers based on UiO-66 (named UiO-66@NIPs) was synthesized according the same steps without tyramine for comparison. The characterization of obtained UiO-66@MIPs was investigated through a series of characterization experiments. The results indicated that the octahedral shaped UiO-66 was encapsulated in the sol-gel polymer film, with a desirable thermal stability and possessed a specific surface area (SSA) of 994.3 m(2)·g(−1). The imprinting factor of the UiO-66@MIPs for tyramine was 1.956 in static experiment. This indicates the synthesized UiO-66@MIPs have outstanding performance compered to UiO-66@NIPs on the static adsorption quantity and selective adsorption affinity. It’s to make use of advantages of the synthetic materials to develop a quartz crystal microbalance (QCM) sensor for the sensitive detection of tyramine. The detection limit of the system was 61.65 μg·L(−1) within measurable concentration range from 80 to 500 μg·L(−1). The prepared QCM sensor was verified in selectivity and application. The UiO-66@MIPs possess good behavior on selectivity, absorptivity, and chemical stability, so the UiO-66@MIPs achieve accurate and rapid trace detection of biogenic amines in food combining with the quartz crystal microbalance.