Cargando…

Feasibility of imaging (90)Y microspheres at diagnostic activity levels for hepatic radioembolization treatment planning

PURPOSE: Prior to (90)Y hepatic radioembolization, a dosage of (99m)Tc‐macroaggregated albumin ((99m)Tc‐MAA) is administered to simulate the distribution of the (90)Y‐loaded microspheres. This pretreatment procedure enables lung shunt estimation, detection of potential extrahepatic depositions, and...

Descripción completa

Detalles Bibliográficos
Autores principales: Kunnen, Britt, Dietze, Martijn M. A., Braat, Arthur J. A. T., Lam, Marnix G. E. H., Viergever, Max A., de Jong, Hugo W. A. M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7078991/
https://www.ncbi.nlm.nih.gov/pubmed/31855282
http://dx.doi.org/10.1002/mp.13974
_version_ 1783507734913613824
author Kunnen, Britt
Dietze, Martijn M. A.
Braat, Arthur J. A. T.
Lam, Marnix G. E. H.
Viergever, Max A.
de Jong, Hugo W. A. M.
author_facet Kunnen, Britt
Dietze, Martijn M. A.
Braat, Arthur J. A. T.
Lam, Marnix G. E. H.
Viergever, Max A.
de Jong, Hugo W. A. M.
author_sort Kunnen, Britt
collection PubMed
description PURPOSE: Prior to (90)Y hepatic radioembolization, a dosage of (99m)Tc‐macroaggregated albumin ((99m)Tc‐MAA) is administered to simulate the distribution of the (90)Y‐loaded microspheres. This pretreatment procedure enables lung shunt estimation, detection of potential extrahepatic depositions, and estimation of the intrahepatic dose distribution. However, the predictive accuracy of the MAA particle distribution is often limited. Ideally, (90)Y microspheres would also be used for the pretreatment procedure. Based on previous research, the pretreatment activity should be limited to the estimated safety threshold of 100 MBq, making imaging challenging. The purpose of this study was to evaluate the quality of intra‐ and extrahepatic imaging of (90)Y‐based pretreatment positron emission tomography/computed tomography (PET/CT) and quantitative single photon emission computed tomography (SPECT)/CT scans, by means of phantom experiments and a patient study. METHODS: An anthropomorphic phantom with three extrahepatic depositions was filled with (90)Y chloride to simulate a lung shunt fraction (LSF) of 5.3% and a tumor to nontumor ratio (T/N) of 7.9. PET /CT (Siemens Biograph mCT) and Bremsstrahlung SPECT/CT (Siemens Symbia T16) images were acquired at activities ranging from 1999 MBq down to 24 MBq, representing post‐ and pretreatment activities. PET/CT images were reconstructed with the clinical protocol and SPECT/CT images were reconstructed with a quantitative Monte Carlo‐based reconstruction protocol. Estimated LSF, T/N, contrast to noise ratio of all extrahepatic depositions, and liver parenchymal and tumor dose were compared with the phantom ground truth. A clinically reconstructed SPECT/CT of 150 MBq (99m)Tc represented the current clinical standard. In addition, a (90)Y pretreatment scan was simulated for a patient by acquiring posttreatment PET/CT and SPECT/CT data with shortened acquisition times. RESULTS: At an activity of 100 MBq (90)Y, PET/CT overestimated LSF [+10 percentage point (pp)], underestimated liver parenchymal dose (−3 Gy/GBq), and could not detect the extrahepatic depositions. SPECT/CT more accurately estimated LSF (−0.7 pp), parenchymal dose (−0.3 Gy/GBq) and could detect all three extrahepatic depositions. (99m)Tc SPECT/CT showed similar accuracy as (90)Y SPECT/CT (LSF: +0.2 pp, parenchymal dose: +0.4 Gy/GBq, all extrahepatic depositions visible), although the noise level in the liver compartment was considerably lower for (99m)Tc SPECT/CT compared to (90)Y SPECT/CT. The patient’s SPECT/CT simulating a pretreatment (90)Y procedure accurately represented the posttreatment (90)Y microsphere distribution. CONCLUSIONS: Quantitative SPECT/CT of 100 MBq (90)Y could accurately estimate LSF, T/N, parenchymal and tumor dose, and visualize extrahepatic depositions.
format Online
Article
Text
id pubmed-7078991
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-70789912020-03-19 Feasibility of imaging (90)Y microspheres at diagnostic activity levels for hepatic radioembolization treatment planning Kunnen, Britt Dietze, Martijn M. A. Braat, Arthur J. A. T. Lam, Marnix G. E. H. Viergever, Max A. de Jong, Hugo W. A. M. Med Phys QUANTITATIVE IMAGING AND IMAGE PROCESSING PURPOSE: Prior to (90)Y hepatic radioembolization, a dosage of (99m)Tc‐macroaggregated albumin ((99m)Tc‐MAA) is administered to simulate the distribution of the (90)Y‐loaded microspheres. This pretreatment procedure enables lung shunt estimation, detection of potential extrahepatic depositions, and estimation of the intrahepatic dose distribution. However, the predictive accuracy of the MAA particle distribution is often limited. Ideally, (90)Y microspheres would also be used for the pretreatment procedure. Based on previous research, the pretreatment activity should be limited to the estimated safety threshold of 100 MBq, making imaging challenging. The purpose of this study was to evaluate the quality of intra‐ and extrahepatic imaging of (90)Y‐based pretreatment positron emission tomography/computed tomography (PET/CT) and quantitative single photon emission computed tomography (SPECT)/CT scans, by means of phantom experiments and a patient study. METHODS: An anthropomorphic phantom with three extrahepatic depositions was filled with (90)Y chloride to simulate a lung shunt fraction (LSF) of 5.3% and a tumor to nontumor ratio (T/N) of 7.9. PET /CT (Siemens Biograph mCT) and Bremsstrahlung SPECT/CT (Siemens Symbia T16) images were acquired at activities ranging from 1999 MBq down to 24 MBq, representing post‐ and pretreatment activities. PET/CT images were reconstructed with the clinical protocol and SPECT/CT images were reconstructed with a quantitative Monte Carlo‐based reconstruction protocol. Estimated LSF, T/N, contrast to noise ratio of all extrahepatic depositions, and liver parenchymal and tumor dose were compared with the phantom ground truth. A clinically reconstructed SPECT/CT of 150 MBq (99m)Tc represented the current clinical standard. In addition, a (90)Y pretreatment scan was simulated for a patient by acquiring posttreatment PET/CT and SPECT/CT data with shortened acquisition times. RESULTS: At an activity of 100 MBq (90)Y, PET/CT overestimated LSF [+10 percentage point (pp)], underestimated liver parenchymal dose (−3 Gy/GBq), and could not detect the extrahepatic depositions. SPECT/CT more accurately estimated LSF (−0.7 pp), parenchymal dose (−0.3 Gy/GBq) and could detect all three extrahepatic depositions. (99m)Tc SPECT/CT showed similar accuracy as (90)Y SPECT/CT (LSF: +0.2 pp, parenchymal dose: +0.4 Gy/GBq, all extrahepatic depositions visible), although the noise level in the liver compartment was considerably lower for (99m)Tc SPECT/CT compared to (90)Y SPECT/CT. The patient’s SPECT/CT simulating a pretreatment (90)Y procedure accurately represented the posttreatment (90)Y microsphere distribution. CONCLUSIONS: Quantitative SPECT/CT of 100 MBq (90)Y could accurately estimate LSF, T/N, parenchymal and tumor dose, and visualize extrahepatic depositions. John Wiley and Sons Inc. 2020-01-20 2020-03 /pmc/articles/PMC7078991/ /pubmed/31855282 http://dx.doi.org/10.1002/mp.13974 Text en © 2019 The Authors. Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle QUANTITATIVE IMAGING AND IMAGE PROCESSING
Kunnen, Britt
Dietze, Martijn M. A.
Braat, Arthur J. A. T.
Lam, Marnix G. E. H.
Viergever, Max A.
de Jong, Hugo W. A. M.
Feasibility of imaging (90)Y microspheres at diagnostic activity levels for hepatic radioembolization treatment planning
title Feasibility of imaging (90)Y microspheres at diagnostic activity levels for hepatic radioembolization treatment planning
title_full Feasibility of imaging (90)Y microspheres at diagnostic activity levels for hepatic radioembolization treatment planning
title_fullStr Feasibility of imaging (90)Y microspheres at diagnostic activity levels for hepatic radioembolization treatment planning
title_full_unstemmed Feasibility of imaging (90)Y microspheres at diagnostic activity levels for hepatic radioembolization treatment planning
title_short Feasibility of imaging (90)Y microspheres at diagnostic activity levels for hepatic radioembolization treatment planning
title_sort feasibility of imaging (90)y microspheres at diagnostic activity levels for hepatic radioembolization treatment planning
topic QUANTITATIVE IMAGING AND IMAGE PROCESSING
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7078991/
https://www.ncbi.nlm.nih.gov/pubmed/31855282
http://dx.doi.org/10.1002/mp.13974
work_keys_str_mv AT kunnenbritt feasibilityofimaging90ymicrospheresatdiagnosticactivitylevelsforhepaticradioembolizationtreatmentplanning
AT dietzemartijnma feasibilityofimaging90ymicrospheresatdiagnosticactivitylevelsforhepaticradioembolizationtreatmentplanning
AT braatarthurjat feasibilityofimaging90ymicrospheresatdiagnosticactivitylevelsforhepaticradioembolizationtreatmentplanning
AT lammarnixgeh feasibilityofimaging90ymicrospheresatdiagnosticactivitylevelsforhepaticradioembolizationtreatmentplanning
AT viergevermaxa feasibilityofimaging90ymicrospheresatdiagnosticactivitylevelsforhepaticradioembolizationtreatmentplanning
AT dejonghugowam feasibilityofimaging90ymicrospheresatdiagnosticactivitylevelsforhepaticradioembolizationtreatmentplanning