Cargando…
Feasibility of imaging (90)Y microspheres at diagnostic activity levels for hepatic radioembolization treatment planning
PURPOSE: Prior to (90)Y hepatic radioembolization, a dosage of (99m)Tc‐macroaggregated albumin ((99m)Tc‐MAA) is administered to simulate the distribution of the (90)Y‐loaded microspheres. This pretreatment procedure enables lung shunt estimation, detection of potential extrahepatic depositions, and...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7078991/ https://www.ncbi.nlm.nih.gov/pubmed/31855282 http://dx.doi.org/10.1002/mp.13974 |
_version_ | 1783507734913613824 |
---|---|
author | Kunnen, Britt Dietze, Martijn M. A. Braat, Arthur J. A. T. Lam, Marnix G. E. H. Viergever, Max A. de Jong, Hugo W. A. M. |
author_facet | Kunnen, Britt Dietze, Martijn M. A. Braat, Arthur J. A. T. Lam, Marnix G. E. H. Viergever, Max A. de Jong, Hugo W. A. M. |
author_sort | Kunnen, Britt |
collection | PubMed |
description | PURPOSE: Prior to (90)Y hepatic radioembolization, a dosage of (99m)Tc‐macroaggregated albumin ((99m)Tc‐MAA) is administered to simulate the distribution of the (90)Y‐loaded microspheres. This pretreatment procedure enables lung shunt estimation, detection of potential extrahepatic depositions, and estimation of the intrahepatic dose distribution. However, the predictive accuracy of the MAA particle distribution is often limited. Ideally, (90)Y microspheres would also be used for the pretreatment procedure. Based on previous research, the pretreatment activity should be limited to the estimated safety threshold of 100 MBq, making imaging challenging. The purpose of this study was to evaluate the quality of intra‐ and extrahepatic imaging of (90)Y‐based pretreatment positron emission tomography/computed tomography (PET/CT) and quantitative single photon emission computed tomography (SPECT)/CT scans, by means of phantom experiments and a patient study. METHODS: An anthropomorphic phantom with three extrahepatic depositions was filled with (90)Y chloride to simulate a lung shunt fraction (LSF) of 5.3% and a tumor to nontumor ratio (T/N) of 7.9. PET /CT (Siemens Biograph mCT) and Bremsstrahlung SPECT/CT (Siemens Symbia T16) images were acquired at activities ranging from 1999 MBq down to 24 MBq, representing post‐ and pretreatment activities. PET/CT images were reconstructed with the clinical protocol and SPECT/CT images were reconstructed with a quantitative Monte Carlo‐based reconstruction protocol. Estimated LSF, T/N, contrast to noise ratio of all extrahepatic depositions, and liver parenchymal and tumor dose were compared with the phantom ground truth. A clinically reconstructed SPECT/CT of 150 MBq (99m)Tc represented the current clinical standard. In addition, a (90)Y pretreatment scan was simulated for a patient by acquiring posttreatment PET/CT and SPECT/CT data with shortened acquisition times. RESULTS: At an activity of 100 MBq (90)Y, PET/CT overestimated LSF [+10 percentage point (pp)], underestimated liver parenchymal dose (−3 Gy/GBq), and could not detect the extrahepatic depositions. SPECT/CT more accurately estimated LSF (−0.7 pp), parenchymal dose (−0.3 Gy/GBq) and could detect all three extrahepatic depositions. (99m)Tc SPECT/CT showed similar accuracy as (90)Y SPECT/CT (LSF: +0.2 pp, parenchymal dose: +0.4 Gy/GBq, all extrahepatic depositions visible), although the noise level in the liver compartment was considerably lower for (99m)Tc SPECT/CT compared to (90)Y SPECT/CT. The patient’s SPECT/CT simulating a pretreatment (90)Y procedure accurately represented the posttreatment (90)Y microsphere distribution. CONCLUSIONS: Quantitative SPECT/CT of 100 MBq (90)Y could accurately estimate LSF, T/N, parenchymal and tumor dose, and visualize extrahepatic depositions. |
format | Online Article Text |
id | pubmed-7078991 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-70789912020-03-19 Feasibility of imaging (90)Y microspheres at diagnostic activity levels for hepatic radioembolization treatment planning Kunnen, Britt Dietze, Martijn M. A. Braat, Arthur J. A. T. Lam, Marnix G. E. H. Viergever, Max A. de Jong, Hugo W. A. M. Med Phys QUANTITATIVE IMAGING AND IMAGE PROCESSING PURPOSE: Prior to (90)Y hepatic radioembolization, a dosage of (99m)Tc‐macroaggregated albumin ((99m)Tc‐MAA) is administered to simulate the distribution of the (90)Y‐loaded microspheres. This pretreatment procedure enables lung shunt estimation, detection of potential extrahepatic depositions, and estimation of the intrahepatic dose distribution. However, the predictive accuracy of the MAA particle distribution is often limited. Ideally, (90)Y microspheres would also be used for the pretreatment procedure. Based on previous research, the pretreatment activity should be limited to the estimated safety threshold of 100 MBq, making imaging challenging. The purpose of this study was to evaluate the quality of intra‐ and extrahepatic imaging of (90)Y‐based pretreatment positron emission tomography/computed tomography (PET/CT) and quantitative single photon emission computed tomography (SPECT)/CT scans, by means of phantom experiments and a patient study. METHODS: An anthropomorphic phantom with three extrahepatic depositions was filled with (90)Y chloride to simulate a lung shunt fraction (LSF) of 5.3% and a tumor to nontumor ratio (T/N) of 7.9. PET /CT (Siemens Biograph mCT) and Bremsstrahlung SPECT/CT (Siemens Symbia T16) images were acquired at activities ranging from 1999 MBq down to 24 MBq, representing post‐ and pretreatment activities. PET/CT images were reconstructed with the clinical protocol and SPECT/CT images were reconstructed with a quantitative Monte Carlo‐based reconstruction protocol. Estimated LSF, T/N, contrast to noise ratio of all extrahepatic depositions, and liver parenchymal and tumor dose were compared with the phantom ground truth. A clinically reconstructed SPECT/CT of 150 MBq (99m)Tc represented the current clinical standard. In addition, a (90)Y pretreatment scan was simulated for a patient by acquiring posttreatment PET/CT and SPECT/CT data with shortened acquisition times. RESULTS: At an activity of 100 MBq (90)Y, PET/CT overestimated LSF [+10 percentage point (pp)], underestimated liver parenchymal dose (−3 Gy/GBq), and could not detect the extrahepatic depositions. SPECT/CT more accurately estimated LSF (−0.7 pp), parenchymal dose (−0.3 Gy/GBq) and could detect all three extrahepatic depositions. (99m)Tc SPECT/CT showed similar accuracy as (90)Y SPECT/CT (LSF: +0.2 pp, parenchymal dose: +0.4 Gy/GBq, all extrahepatic depositions visible), although the noise level in the liver compartment was considerably lower for (99m)Tc SPECT/CT compared to (90)Y SPECT/CT. The patient’s SPECT/CT simulating a pretreatment (90)Y procedure accurately represented the posttreatment (90)Y microsphere distribution. CONCLUSIONS: Quantitative SPECT/CT of 100 MBq (90)Y could accurately estimate LSF, T/N, parenchymal and tumor dose, and visualize extrahepatic depositions. John Wiley and Sons Inc. 2020-01-20 2020-03 /pmc/articles/PMC7078991/ /pubmed/31855282 http://dx.doi.org/10.1002/mp.13974 Text en © 2019 The Authors. Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. |
spellingShingle | QUANTITATIVE IMAGING AND IMAGE PROCESSING Kunnen, Britt Dietze, Martijn M. A. Braat, Arthur J. A. T. Lam, Marnix G. E. H. Viergever, Max A. de Jong, Hugo W. A. M. Feasibility of imaging (90)Y microspheres at diagnostic activity levels for hepatic radioembolization treatment planning |
title | Feasibility of imaging (90)Y microspheres at diagnostic activity levels for hepatic radioembolization treatment planning |
title_full | Feasibility of imaging (90)Y microspheres at diagnostic activity levels for hepatic radioembolization treatment planning |
title_fullStr | Feasibility of imaging (90)Y microspheres at diagnostic activity levels for hepatic radioembolization treatment planning |
title_full_unstemmed | Feasibility of imaging (90)Y microspheres at diagnostic activity levels for hepatic radioembolization treatment planning |
title_short | Feasibility of imaging (90)Y microspheres at diagnostic activity levels for hepatic radioembolization treatment planning |
title_sort | feasibility of imaging (90)y microspheres at diagnostic activity levels for hepatic radioembolization treatment planning |
topic | QUANTITATIVE IMAGING AND IMAGE PROCESSING |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7078991/ https://www.ncbi.nlm.nih.gov/pubmed/31855282 http://dx.doi.org/10.1002/mp.13974 |
work_keys_str_mv | AT kunnenbritt feasibilityofimaging90ymicrospheresatdiagnosticactivitylevelsforhepaticradioembolizationtreatmentplanning AT dietzemartijnma feasibilityofimaging90ymicrospheresatdiagnosticactivitylevelsforhepaticradioembolizationtreatmentplanning AT braatarthurjat feasibilityofimaging90ymicrospheresatdiagnosticactivitylevelsforhepaticradioembolizationtreatmentplanning AT lammarnixgeh feasibilityofimaging90ymicrospheresatdiagnosticactivitylevelsforhepaticradioembolizationtreatmentplanning AT viergevermaxa feasibilityofimaging90ymicrospheresatdiagnosticactivitylevelsforhepaticradioembolizationtreatmentplanning AT dejonghugowam feasibilityofimaging90ymicrospheresatdiagnosticactivitylevelsforhepaticradioembolizationtreatmentplanning |