Cargando…
Stationary tissue background correction increases the precision of clinical evaluation of intra-cardiac shunts by cardiovascular magnetic resonance
We aimed to evaluate the clinical utility of stationary tissue background phase correction for affecting precision in the measurement of Qp/Qs by cardiovascular magnetic resonance (CMR). We enrolled consecutive patients (n = 91) referred for CMR at 1.5T without suspicion of cardiac shunt, and patien...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7081189/ https://www.ncbi.nlm.nih.gov/pubmed/32193468 http://dx.doi.org/10.1038/s41598-020-61812-7 |
_version_ | 1783508124887416832 |
---|---|
author | Nickander, Jannike Lundin, Magnus Abdula, Goran Jenner, Jonas Maret, Eva Sörensson, Peder Heiberg, Einar Sigfridsson, Andreas Ugander, Martin |
author_facet | Nickander, Jannike Lundin, Magnus Abdula, Goran Jenner, Jonas Maret, Eva Sörensson, Peder Heiberg, Einar Sigfridsson, Andreas Ugander, Martin |
author_sort | Nickander, Jannike |
collection | PubMed |
description | We aimed to evaluate the clinical utility of stationary tissue background phase correction for affecting precision in the measurement of Qp/Qs by cardiovascular magnetic resonance (CMR). We enrolled consecutive patients (n = 91) referred for CMR at 1.5T without suspicion of cardiac shunt, and patients (n = 10) with verified cardiac shunts in this retrospective study. All patients underwent phase contrast flow quantification in the ascending aorta and pulmonary trunk. Flow was quantified using two semi-automatic software platforms (SyngoVia VA30, Vendor 1; Segment 2.0R4534, Vendor 2). Measurements were performed both uncorrected and corrected for linear (Vendor 1 and Vendor 2) or quadratic (Vendor 2) background phase. The proportion of patients outside the normal range of Qp/Qs was compared using the McNemar’s test. Compared to uncorrected measurements, there were fewer patients with a Qp/Qs outside the normal range following linear correction using Vendor 1 (10% vs 18%, p < 0.001), and Vendor 2 (10% vs 18%, p < 0.001), and following quadratic correction using Vendor 2 (7% vs 18%, p < 0.001). No patient with known shunt was reclassified as normal following stationary background correction. Therefore, we conclude that stationary tissue background correction reduces the number of patients with a Qp/Qs ratio outside the normal range in a consecutive clinical population, while simultaneously not reclassifying any patient with known cardiac shunts as having a normal Qp/Qs. Stationary tissue background correction may be used in clinical patients to increase diagnostic precision. |
format | Online Article Text |
id | pubmed-7081189 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-70811892020-03-23 Stationary tissue background correction increases the precision of clinical evaluation of intra-cardiac shunts by cardiovascular magnetic resonance Nickander, Jannike Lundin, Magnus Abdula, Goran Jenner, Jonas Maret, Eva Sörensson, Peder Heiberg, Einar Sigfridsson, Andreas Ugander, Martin Sci Rep Article We aimed to evaluate the clinical utility of stationary tissue background phase correction for affecting precision in the measurement of Qp/Qs by cardiovascular magnetic resonance (CMR). We enrolled consecutive patients (n = 91) referred for CMR at 1.5T without suspicion of cardiac shunt, and patients (n = 10) with verified cardiac shunts in this retrospective study. All patients underwent phase contrast flow quantification in the ascending aorta and pulmonary trunk. Flow was quantified using two semi-automatic software platforms (SyngoVia VA30, Vendor 1; Segment 2.0R4534, Vendor 2). Measurements were performed both uncorrected and corrected for linear (Vendor 1 and Vendor 2) or quadratic (Vendor 2) background phase. The proportion of patients outside the normal range of Qp/Qs was compared using the McNemar’s test. Compared to uncorrected measurements, there were fewer patients with a Qp/Qs outside the normal range following linear correction using Vendor 1 (10% vs 18%, p < 0.001), and Vendor 2 (10% vs 18%, p < 0.001), and following quadratic correction using Vendor 2 (7% vs 18%, p < 0.001). No patient with known shunt was reclassified as normal following stationary background correction. Therefore, we conclude that stationary tissue background correction reduces the number of patients with a Qp/Qs ratio outside the normal range in a consecutive clinical population, while simultaneously not reclassifying any patient with known cardiac shunts as having a normal Qp/Qs. Stationary tissue background correction may be used in clinical patients to increase diagnostic precision. Nature Publishing Group UK 2020-03-19 /pmc/articles/PMC7081189/ /pubmed/32193468 http://dx.doi.org/10.1038/s41598-020-61812-7 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Nickander, Jannike Lundin, Magnus Abdula, Goran Jenner, Jonas Maret, Eva Sörensson, Peder Heiberg, Einar Sigfridsson, Andreas Ugander, Martin Stationary tissue background correction increases the precision of clinical evaluation of intra-cardiac shunts by cardiovascular magnetic resonance |
title | Stationary tissue background correction increases the precision of clinical evaluation of intra-cardiac shunts by cardiovascular magnetic resonance |
title_full | Stationary tissue background correction increases the precision of clinical evaluation of intra-cardiac shunts by cardiovascular magnetic resonance |
title_fullStr | Stationary tissue background correction increases the precision of clinical evaluation of intra-cardiac shunts by cardiovascular magnetic resonance |
title_full_unstemmed | Stationary tissue background correction increases the precision of clinical evaluation of intra-cardiac shunts by cardiovascular magnetic resonance |
title_short | Stationary tissue background correction increases the precision of clinical evaluation of intra-cardiac shunts by cardiovascular magnetic resonance |
title_sort | stationary tissue background correction increases the precision of clinical evaluation of intra-cardiac shunts by cardiovascular magnetic resonance |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7081189/ https://www.ncbi.nlm.nih.gov/pubmed/32193468 http://dx.doi.org/10.1038/s41598-020-61812-7 |
work_keys_str_mv | AT nickanderjannike stationarytissuebackgroundcorrectionincreasestheprecisionofclinicalevaluationofintracardiacshuntsbycardiovascularmagneticresonance AT lundinmagnus stationarytissuebackgroundcorrectionincreasestheprecisionofclinicalevaluationofintracardiacshuntsbycardiovascularmagneticresonance AT abdulagoran stationarytissuebackgroundcorrectionincreasestheprecisionofclinicalevaluationofintracardiacshuntsbycardiovascularmagneticresonance AT jennerjonas stationarytissuebackgroundcorrectionincreasestheprecisionofclinicalevaluationofintracardiacshuntsbycardiovascularmagneticresonance AT mareteva stationarytissuebackgroundcorrectionincreasestheprecisionofclinicalevaluationofintracardiacshuntsbycardiovascularmagneticresonance AT sorenssonpeder stationarytissuebackgroundcorrectionincreasestheprecisionofclinicalevaluationofintracardiacshuntsbycardiovascularmagneticresonance AT heibergeinar stationarytissuebackgroundcorrectionincreasestheprecisionofclinicalevaluationofintracardiacshuntsbycardiovascularmagneticresonance AT sigfridssonandreas stationarytissuebackgroundcorrectionincreasestheprecisionofclinicalevaluationofintracardiacshuntsbycardiovascularmagneticresonance AT ugandermartin stationarytissuebackgroundcorrectionincreasestheprecisionofclinicalevaluationofintracardiacshuntsbycardiovascularmagneticresonance |