Cargando…

Resolution-enhanced imaging using interferenceless coded aperture correlation holography with sparse point response

Interferenceless coded aperture correlation holography (I-COACH) is a non-scanning, motionless, incoherent digital holography technique. In this study we use a special type of I-COACH in which its point spread hologram (PSH) is ensemble of sparse dots. With this PSH an imaging resolution beyond the...

Descripción completa

Detalles Bibliográficos
Autores principales: Rai, Mani Ratnam, Rosen, Joseph
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7081337/
https://www.ncbi.nlm.nih.gov/pubmed/32193412
http://dx.doi.org/10.1038/s41598-020-61754-0
_version_ 1783508157860937728
author Rai, Mani Ratnam
Rosen, Joseph
author_facet Rai, Mani Ratnam
Rosen, Joseph
author_sort Rai, Mani Ratnam
collection PubMed
description Interferenceless coded aperture correlation holography (I-COACH) is a non-scanning, motionless, incoherent digital holography technique. In this study we use a special type of I-COACH in which its point spread hologram (PSH) is ensemble of sparse dots. With this PSH an imaging resolution beyond the classic diffraction limit is demonstrated. This resolution improvement is achieved due to the position of the coded aperture between the object and the lens-based imaging system. The coded aperture scatters part of the light, that otherwise is blocked by the system aperture, into the optical system, and by doing that, extends the effective numerical aperture of the system. The use of sparse PSH increases the signal-to-noise ratio of the entire imaging system. A lateral resolution enhancement by a factor of about 1.6 was noted in the case of I-COACH compared to direct imaging.
format Online
Article
Text
id pubmed-7081337
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-70813372020-03-23 Resolution-enhanced imaging using interferenceless coded aperture correlation holography with sparse point response Rai, Mani Ratnam Rosen, Joseph Sci Rep Article Interferenceless coded aperture correlation holography (I-COACH) is a non-scanning, motionless, incoherent digital holography technique. In this study we use a special type of I-COACH in which its point spread hologram (PSH) is ensemble of sparse dots. With this PSH an imaging resolution beyond the classic diffraction limit is demonstrated. This resolution improvement is achieved due to the position of the coded aperture between the object and the lens-based imaging system. The coded aperture scatters part of the light, that otherwise is blocked by the system aperture, into the optical system, and by doing that, extends the effective numerical aperture of the system. The use of sparse PSH increases the signal-to-noise ratio of the entire imaging system. A lateral resolution enhancement by a factor of about 1.6 was noted in the case of I-COACH compared to direct imaging. Nature Publishing Group UK 2020-03-19 /pmc/articles/PMC7081337/ /pubmed/32193412 http://dx.doi.org/10.1038/s41598-020-61754-0 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Rai, Mani Ratnam
Rosen, Joseph
Resolution-enhanced imaging using interferenceless coded aperture correlation holography with sparse point response
title Resolution-enhanced imaging using interferenceless coded aperture correlation holography with sparse point response
title_full Resolution-enhanced imaging using interferenceless coded aperture correlation holography with sparse point response
title_fullStr Resolution-enhanced imaging using interferenceless coded aperture correlation holography with sparse point response
title_full_unstemmed Resolution-enhanced imaging using interferenceless coded aperture correlation holography with sparse point response
title_short Resolution-enhanced imaging using interferenceless coded aperture correlation holography with sparse point response
title_sort resolution-enhanced imaging using interferenceless coded aperture correlation holography with sparse point response
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7081337/
https://www.ncbi.nlm.nih.gov/pubmed/32193412
http://dx.doi.org/10.1038/s41598-020-61754-0
work_keys_str_mv AT raimaniratnam resolutionenhancedimagingusinginterferencelesscodedaperturecorrelationholographywithsparsepointresponse
AT rosenjoseph resolutionenhancedimagingusinginterferencelesscodedaperturecorrelationholographywithsparsepointresponse