Cargando…

Reference intervals established using indirect method for serum ferritin assayed on Abbott Architect i2000(SR) analyzer in Chinese adults

BACKGROUND: Serum ferritin (SF) test has been widely used in clinical practice. However, its reference intervals (RIs) vary depending on the analytical method and ethnic origin. This study was to establish the RIs using indirect method for SF in Chinese adults. METHODS: SF was assayed on Abbott i200...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Qing‐ping, Guo, Lin‐ying, Lu, Zhi‐yong, Gu, Jian‐wen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7083431/
https://www.ncbi.nlm.nih.gov/pubmed/31674712
http://dx.doi.org/10.1002/jcla.23083
_version_ 1783508532320010240
author Wang, Qing‐ping
Guo, Lin‐ying
Lu, Zhi‐yong
Gu, Jian‐wen
author_facet Wang, Qing‐ping
Guo, Lin‐ying
Lu, Zhi‐yong
Gu, Jian‐wen
author_sort Wang, Qing‐ping
collection PubMed
description BACKGROUND: Serum ferritin (SF) test has been widely used in clinical practice. However, its reference intervals (RIs) vary depending on the analytical method and ethnic origin. This study was to establish the RIs using indirect method for SF in Chinese adults. METHODS: SF was assayed on Abbott i2000(SR) analyzer. The SF test results of all health examinees (8913 males aged 18‐93 years and 5397 females aged 18‐90 years) between December 2010 and April 2019 were obtained from our laboratory information system. After Box‐Cox transformation of raw data and exclusion of outliers, parametric and non‐parametric approaches were used to calculate 95% RIs. The correlation between SF levels and ages, and the differences in SF levels between subgroups were also analyzed. RESULTS: SF levels in females were significantly different from those in males (Z = 88.96, Z* = 23.17; Z > Z*) and showed a weak positive correlation with age (r = .466, P < .0001). The RIs based on parametric approach in males were 66.12‐561.58 µg/L, whereas in all females were 3.59‐269.59 µg/L, females aged <50 years 3.26‐148.02 µg/L and those aged ≥50 years 17.28‐303.27 µg/L. The RIs based on non‐parametric approach in males were 65.00‐571.37 µg/L whereas in all females were 4.00‐254.00 µg/L, females aged <50 years 4.00‐152.00 µg/L and those aged ≥50 years 16.00‐304.05 µg/L. CONCLUSIONS: Our indirect RIs for SF were markedly different from the manufacturer's recommended RIs and might be more suitable for Chinese adults, which would be helpful in interpreting laboratory data and clinical decision‐making.
format Online
Article
Text
id pubmed-7083431
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-70834312020-03-24 Reference intervals established using indirect method for serum ferritin assayed on Abbott Architect i2000(SR) analyzer in Chinese adults Wang, Qing‐ping Guo, Lin‐ying Lu, Zhi‐yong Gu, Jian‐wen J Clin Lab Anal Research Articles BACKGROUND: Serum ferritin (SF) test has been widely used in clinical practice. However, its reference intervals (RIs) vary depending on the analytical method and ethnic origin. This study was to establish the RIs using indirect method for SF in Chinese adults. METHODS: SF was assayed on Abbott i2000(SR) analyzer. The SF test results of all health examinees (8913 males aged 18‐93 years and 5397 females aged 18‐90 years) between December 2010 and April 2019 were obtained from our laboratory information system. After Box‐Cox transformation of raw data and exclusion of outliers, parametric and non‐parametric approaches were used to calculate 95% RIs. The correlation between SF levels and ages, and the differences in SF levels between subgroups were also analyzed. RESULTS: SF levels in females were significantly different from those in males (Z = 88.96, Z* = 23.17; Z > Z*) and showed a weak positive correlation with age (r = .466, P < .0001). The RIs based on parametric approach in males were 66.12‐561.58 µg/L, whereas in all females were 3.59‐269.59 µg/L, females aged <50 years 3.26‐148.02 µg/L and those aged ≥50 years 17.28‐303.27 µg/L. The RIs based on non‐parametric approach in males were 65.00‐571.37 µg/L whereas in all females were 4.00‐254.00 µg/L, females aged <50 years 4.00‐152.00 µg/L and those aged ≥50 years 16.00‐304.05 µg/L. CONCLUSIONS: Our indirect RIs for SF were markedly different from the manufacturer's recommended RIs and might be more suitable for Chinese adults, which would be helpful in interpreting laboratory data and clinical decision‐making. John Wiley and Sons Inc. 2019-11-01 /pmc/articles/PMC7083431/ /pubmed/31674712 http://dx.doi.org/10.1002/jcla.23083 Text en © 2019 The Authors. Journal of Clinical Laboratory Analysis published by Wiley Periodicals, Inc. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Articles
Wang, Qing‐ping
Guo, Lin‐ying
Lu, Zhi‐yong
Gu, Jian‐wen
Reference intervals established using indirect method for serum ferritin assayed on Abbott Architect i2000(SR) analyzer in Chinese adults
title Reference intervals established using indirect method for serum ferritin assayed on Abbott Architect i2000(SR) analyzer in Chinese adults
title_full Reference intervals established using indirect method for serum ferritin assayed on Abbott Architect i2000(SR) analyzer in Chinese adults
title_fullStr Reference intervals established using indirect method for serum ferritin assayed on Abbott Architect i2000(SR) analyzer in Chinese adults
title_full_unstemmed Reference intervals established using indirect method for serum ferritin assayed on Abbott Architect i2000(SR) analyzer in Chinese adults
title_short Reference intervals established using indirect method for serum ferritin assayed on Abbott Architect i2000(SR) analyzer in Chinese adults
title_sort reference intervals established using indirect method for serum ferritin assayed on abbott architect i2000(sr) analyzer in chinese adults
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7083431/
https://www.ncbi.nlm.nih.gov/pubmed/31674712
http://dx.doi.org/10.1002/jcla.23083
work_keys_str_mv AT wangqingping referenceintervalsestablishedusingindirectmethodforserumferritinassayedonabbottarchitecti2000sranalyzerinchineseadults
AT guolinying referenceintervalsestablishedusingindirectmethodforserumferritinassayedonabbottarchitecti2000sranalyzerinchineseadults
AT luzhiyong referenceintervalsestablishedusingindirectmethodforserumferritinassayedonabbottarchitecti2000sranalyzerinchineseadults
AT gujianwen referenceintervalsestablishedusingindirectmethodforserumferritinassayedonabbottarchitecti2000sranalyzerinchineseadults