Cargando…
Failure at the femoral stem extension-condylar interface in a rotating hinge knee without radiographic evidence of loosening
Modular stem extensions have become ubiquitous in revision total knee arthroplasty systems. Although stem extensions are valuable in addressing bone deficiencies and improving implant fixation, the stem extension-condylar interface may be a point of implant failure. We report a case of failure at th...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7083710/ https://www.ncbi.nlm.nih.gov/pubmed/32211472 http://dx.doi.org/10.1016/j.artd.2019.11.002 |
_version_ | 1783508576192430080 |
---|---|
author | Kahan, Michael Estes, Christopher |
author_facet | Kahan, Michael Estes, Christopher |
author_sort | Kahan, Michael |
collection | PubMed |
description | Modular stem extensions have become ubiquitous in revision total knee arthroplasty systems. Although stem extensions are valuable in addressing bone deficiencies and improving implant fixation, the stem extension-condylar interface may be a point of implant failure. We report a case of failure at the femoral stem extension-condylar interface in a Zimmer NexGen Rotating Hinge Knee (Zimmer, Warsaw, IN). Currently, several published case reports describe failure at the femoral stem extension-condylar interface but only 1 case describes loosening at a taper junction without evidence of set screw failure or taper fracture. Furthermore, no published cases describe this type of failure in the Zimmer NexGen Rotating Hinge Knee (Zimmer). |
format | Online Article Text |
id | pubmed-7083710 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-70837102020-03-24 Failure at the femoral stem extension-condylar interface in a rotating hinge knee without radiographic evidence of loosening Kahan, Michael Estes, Christopher Arthroplast Today Case Report Modular stem extensions have become ubiquitous in revision total knee arthroplasty systems. Although stem extensions are valuable in addressing bone deficiencies and improving implant fixation, the stem extension-condylar interface may be a point of implant failure. We report a case of failure at the femoral stem extension-condylar interface in a Zimmer NexGen Rotating Hinge Knee (Zimmer, Warsaw, IN). Currently, several published case reports describe failure at the femoral stem extension-condylar interface but only 1 case describes loosening at a taper junction without evidence of set screw failure or taper fracture. Furthermore, no published cases describe this type of failure in the Zimmer NexGen Rotating Hinge Knee (Zimmer). Elsevier 2019-12-12 /pmc/articles/PMC7083710/ /pubmed/32211472 http://dx.doi.org/10.1016/j.artd.2019.11.002 Text en © 2019 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case Report Kahan, Michael Estes, Christopher Failure at the femoral stem extension-condylar interface in a rotating hinge knee without radiographic evidence of loosening |
title | Failure at the femoral stem extension-condylar interface in a rotating hinge knee without radiographic evidence of loosening |
title_full | Failure at the femoral stem extension-condylar interface in a rotating hinge knee without radiographic evidence of loosening |
title_fullStr | Failure at the femoral stem extension-condylar interface in a rotating hinge knee without radiographic evidence of loosening |
title_full_unstemmed | Failure at the femoral stem extension-condylar interface in a rotating hinge knee without radiographic evidence of loosening |
title_short | Failure at the femoral stem extension-condylar interface in a rotating hinge knee without radiographic evidence of loosening |
title_sort | failure at the femoral stem extension-condylar interface in a rotating hinge knee without radiographic evidence of loosening |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7083710/ https://www.ncbi.nlm.nih.gov/pubmed/32211472 http://dx.doi.org/10.1016/j.artd.2019.11.002 |
work_keys_str_mv | AT kahanmichael failureatthefemoralstemextensioncondylarinterfaceinarotatinghingekneewithoutradiographicevidenceofloosening AT esteschristopher failureatthefemoralstemextensioncondylarinterfaceinarotatinghingekneewithoutradiographicevidenceofloosening |