Cargando…

Evaluation of Anterior Chamber Depth and Anterior Chamber Angle Changing After Phacoemulsification in the Primary Angle Close Suspect Eyes

BACKGROUND: Phacoemulsification surgery has the ability to deeply alter the segment anterior morphology, especially in eye with shallow anterior chamber (AC), narrow anterior chamber angle (ACA). However, the changes of anterior chamber depth (ACD) and ACA on the close angle suspect eyes after phaco...

Descripción completa

Detalles Bibliográficos
Autores principales: Vu, Anh Tuan, Bui, Van Anh, Vu, Hai Long, Quyet, Do, Thai, Than Van, Nga, Vu Thi, Dinh, Toi Chu, Bac, Nguyen Duy
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Republic of Macedonia 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7084008/
https://www.ncbi.nlm.nih.gov/pubmed/32215081
http://dx.doi.org/10.3889/oamjms.2019.378
_version_ 1783508640301318144
author Vu, Anh Tuan
Bui, Van Anh
Vu, Hai Long
Quyet, Do
Thai, Than Van
Nga, Vu Thi
Dinh, Toi Chu
Bac, Nguyen Duy
author_facet Vu, Anh Tuan
Bui, Van Anh
Vu, Hai Long
Quyet, Do
Thai, Than Van
Nga, Vu Thi
Dinh, Toi Chu
Bac, Nguyen Duy
author_sort Vu, Anh Tuan
collection PubMed
description BACKGROUND: Phacoemulsification surgery has the ability to deeply alter the segment anterior morphology, especially in eye with shallow anterior chamber (AC), narrow anterior chamber angle (ACA). However, the changes of anterior chamber depth (ACD) and ACA on the close angle suspect eyes after phacoemulsification have not been mentioned in many studies. So, we conduct this research. AIM: To evaluate the alteration in the ACA and ACD after phacoemulsification in the close angle suspect eyes. METHODS: Interventional study with no control group. Subjects were the primary angle closure suspect (PACS) eyes, that were operated by phacoemulsification with intraocular lens (IOL) at Glaucoma Department of VNIO from December 2017 to October 2018. RESULTS: 29 PACS eyes with cataract were operated by phacoemulsification with intraocular lens. After 3 months of monitoring, the average ACD augmented from 2.082 ± 0.244 to 3.673 ± 0.222 mm. AOD500 increase from 0.183 ± 0.088 to 0.388 ± 0.132 μm, AOD750 increased from 0.278 ± 0.105 to 0.576 ± 0.149 μm. The TISA500 enlarged from 0.068 ± 0.033 to 0.140 ± 0.052 mm(2), TISA750 enlarged from 0.125 ± 0.052 to 0.256 ± 0.089 mm(2) at the third month (p < 0.01). CONCLUSION: Phacoemulsification surgery increases the ACD and enlarged the angle in the PACS eyes.
format Online
Article
Text
id pubmed-7084008
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Republic of Macedonia
record_format MEDLINE/PubMed
spelling pubmed-70840082020-03-25 Evaluation of Anterior Chamber Depth and Anterior Chamber Angle Changing After Phacoemulsification in the Primary Angle Close Suspect Eyes Vu, Anh Tuan Bui, Van Anh Vu, Hai Long Quyet, Do Thai, Than Van Nga, Vu Thi Dinh, Toi Chu Bac, Nguyen Duy Open Access Maced J Med Sci Basic and Clinical Medical Researches in Vietnam BACKGROUND: Phacoemulsification surgery has the ability to deeply alter the segment anterior morphology, especially in eye with shallow anterior chamber (AC), narrow anterior chamber angle (ACA). However, the changes of anterior chamber depth (ACD) and ACA on the close angle suspect eyes after phacoemulsification have not been mentioned in many studies. So, we conduct this research. AIM: To evaluate the alteration in the ACA and ACD after phacoemulsification in the close angle suspect eyes. METHODS: Interventional study with no control group. Subjects were the primary angle closure suspect (PACS) eyes, that were operated by phacoemulsification with intraocular lens (IOL) at Glaucoma Department of VNIO from December 2017 to October 2018. RESULTS: 29 PACS eyes with cataract were operated by phacoemulsification with intraocular lens. After 3 months of monitoring, the average ACD augmented from 2.082 ± 0.244 to 3.673 ± 0.222 mm. AOD500 increase from 0.183 ± 0.088 to 0.388 ± 0.132 μm, AOD750 increased from 0.278 ± 0.105 to 0.576 ± 0.149 μm. The TISA500 enlarged from 0.068 ± 0.033 to 0.140 ± 0.052 mm(2), TISA750 enlarged from 0.125 ± 0.052 to 0.256 ± 0.089 mm(2) at the third month (p < 0.01). CONCLUSION: Phacoemulsification surgery increases the ACD and enlarged the angle in the PACS eyes. Republic of Macedonia 2019-12-20 /pmc/articles/PMC7084008/ /pubmed/32215081 http://dx.doi.org/10.3889/oamjms.2019.378 Text en Copyright: © 2019 Anh Tuan Vu, Van Anh Bui, Hai Long Vu, Do Quyet, Than Van Thai, Vu Thi Nga, Toi Chu Dinh, Nguyen Duy Bac. http://creativecommons.org/licenses/CC BY-NC/4.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0)
spellingShingle Basic and Clinical Medical Researches in Vietnam
Vu, Anh Tuan
Bui, Van Anh
Vu, Hai Long
Quyet, Do
Thai, Than Van
Nga, Vu Thi
Dinh, Toi Chu
Bac, Nguyen Duy
Evaluation of Anterior Chamber Depth and Anterior Chamber Angle Changing After Phacoemulsification in the Primary Angle Close Suspect Eyes
title Evaluation of Anterior Chamber Depth and Anterior Chamber Angle Changing After Phacoemulsification in the Primary Angle Close Suspect Eyes
title_full Evaluation of Anterior Chamber Depth and Anterior Chamber Angle Changing After Phacoemulsification in the Primary Angle Close Suspect Eyes
title_fullStr Evaluation of Anterior Chamber Depth and Anterior Chamber Angle Changing After Phacoemulsification in the Primary Angle Close Suspect Eyes
title_full_unstemmed Evaluation of Anterior Chamber Depth and Anterior Chamber Angle Changing After Phacoemulsification in the Primary Angle Close Suspect Eyes
title_short Evaluation of Anterior Chamber Depth and Anterior Chamber Angle Changing After Phacoemulsification in the Primary Angle Close Suspect Eyes
title_sort evaluation of anterior chamber depth and anterior chamber angle changing after phacoemulsification in the primary angle close suspect eyes
topic Basic and Clinical Medical Researches in Vietnam
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7084008/
https://www.ncbi.nlm.nih.gov/pubmed/32215081
http://dx.doi.org/10.3889/oamjms.2019.378
work_keys_str_mv AT vuanhtuan evaluationofanteriorchamberdepthandanteriorchamberanglechangingafterphacoemulsificationintheprimaryangleclosesuspecteyes
AT buivananh evaluationofanteriorchamberdepthandanteriorchamberanglechangingafterphacoemulsificationintheprimaryangleclosesuspecteyes
AT vuhailong evaluationofanteriorchamberdepthandanteriorchamberanglechangingafterphacoemulsificationintheprimaryangleclosesuspecteyes
AT quyetdo evaluationofanteriorchamberdepthandanteriorchamberanglechangingafterphacoemulsificationintheprimaryangleclosesuspecteyes
AT thaithanvan evaluationofanteriorchamberdepthandanteriorchamberanglechangingafterphacoemulsificationintheprimaryangleclosesuspecteyes
AT ngavuthi evaluationofanteriorchamberdepthandanteriorchamberanglechangingafterphacoemulsificationintheprimaryangleclosesuspecteyes
AT dinhtoichu evaluationofanteriorchamberdepthandanteriorchamberanglechangingafterphacoemulsificationintheprimaryangleclosesuspecteyes
AT bacnguyenduy evaluationofanteriorchamberdepthandanteriorchamberanglechangingafterphacoemulsificationintheprimaryangleclosesuspecteyes