Cargando…

Assessing the Status of Filtering Blebs at 5 Year Post- Trabeculectomy

BACKGROUND: Glaucoma is a common cause of blindness in the world as well as in Vietnam. It is treated by many different methods but trabeculectomy is still the most popular and highly effective surgical method to treat this condition. AIM: To analyze the status of 5 years filtering blebs following t...

Descripción completa

Detalles Bibliográficos
Autores principales: Anh, Bui Thi Van, Dat, Nguyen Thai, Vu, Anh Tuan, Hieu, Nguyen Trung, Quyet, Do, Thai, Than Van, Nga, Vu Thi, Dinh, Toi Chu, Bac, Nguyen Duy
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Republic of Macedonia 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7084019/
https://www.ncbi.nlm.nih.gov/pubmed/32215077
http://dx.doi.org/10.3889/oamjms.2019.374
Descripción
Sumario:BACKGROUND: Glaucoma is a common cause of blindness in the world as well as in Vietnam. It is treated by many different methods but trabeculectomy is still the most popular and highly effective surgical method to treat this condition. AIM: To analyze the status of 5 years filtering blebs following trabeculectomy and to explore multiple factors associated with filtering blebs. METHODS: This is a retrospective, cross-sectional descriptive study. Eyes had been performed trabeculectomy for 5 years were included in these results. The filtering blebs were assessed using slit lamp and OCT. the OCT captured bleb area to evaluate fluid subconjunctival spaces, thickness and height of bleb and to evaluate the related factors RESULTS: A group of 106 primary glaucoma eyes of 97 patients (88 patients with 1 eye, 9 patients 2 eyes) had been performed trabeculectomy for 5 years were taken OCT anterior image. The proportion of female patients is 1.5 times that of male patients. IOP was controlled with or without topical medication in all eyes. The filtering bleb had a high echo reflection, which accounted for 42.5%, the average echo reflection was 38.6%, the low echo reflection response of 18.9%. 66% of the eyes had the aqueous space under the conjunctiva, 65.1% have the aqueous space under sclera flap, the average height of the bleb on OCT was 0.4 mm ± 0.3 mm. Young patients often have a higher rate of bleb fibrosis and loss of function than older patients CONCLUSION: OCT is capable of assessing the function of bleb. After 5 years of trabeculectomy, on the OCT image, most cases of blebs are maintaining drainage function.