Cargando…
Motion Artifact Reduction in Wearable Photoplethysmography Based on Multi-Channel Sensors with Multiple Wavelengths
Photoplethysmography (PPG) is an easy and convenient method by which to measure heart rate (HR). However, PPG signals that optically measure volumetric changes in blood are not robust to motion artifacts. In this paper, we develop a PPG measuring system based on multi-channel sensors with multiple w...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7085621/ https://www.ncbi.nlm.nih.gov/pubmed/32182772 http://dx.doi.org/10.3390/s20051493 |
_version_ | 1783508973879558144 |
---|---|
author | Lee, Jongshill Kim, Minseong Park, Hoon-Ki Kim, In Young |
author_facet | Lee, Jongshill Kim, Minseong Park, Hoon-Ki Kim, In Young |
author_sort | Lee, Jongshill |
collection | PubMed |
description | Photoplethysmography (PPG) is an easy and convenient method by which to measure heart rate (HR). However, PPG signals that optically measure volumetric changes in blood are not robust to motion artifacts. In this paper, we develop a PPG measuring system based on multi-channel sensors with multiple wavelengths and propose a motion artifact reduction algorithm using independent component analysis (ICA). We also propose a truncated singular value decomposition for 12-channel PPG signals, which contain direction and depth information measured using the developed multi-channel PPG measurement system. The performance of the proposed method is evaluated against the R-peaks of an electrocardiogram in terms of sensitivity (Se), positive predictive value (PPV), and failed detection rate (FDR). The experimental results show that Se, PPV, and FDR were 99%, 99.55%, and 0.45% for walking, 96.28%, 99.24%, and 0.77% for fast walking, and 82.49%, 99.83%, and 0.17% for running, respectively. The evaluation shows that the proposed method is effective in reducing errors in HR estimation from PPG signals with motion artifacts in intensive motion situations such as fast walking and running. |
format | Online Article Text |
id | pubmed-7085621 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-70856212020-04-21 Motion Artifact Reduction in Wearable Photoplethysmography Based on Multi-Channel Sensors with Multiple Wavelengths Lee, Jongshill Kim, Minseong Park, Hoon-Ki Kim, In Young Sensors (Basel) Article Photoplethysmography (PPG) is an easy and convenient method by which to measure heart rate (HR). However, PPG signals that optically measure volumetric changes in blood are not robust to motion artifacts. In this paper, we develop a PPG measuring system based on multi-channel sensors with multiple wavelengths and propose a motion artifact reduction algorithm using independent component analysis (ICA). We also propose a truncated singular value decomposition for 12-channel PPG signals, which contain direction and depth information measured using the developed multi-channel PPG measurement system. The performance of the proposed method is evaluated against the R-peaks of an electrocardiogram in terms of sensitivity (Se), positive predictive value (PPV), and failed detection rate (FDR). The experimental results show that Se, PPV, and FDR were 99%, 99.55%, and 0.45% for walking, 96.28%, 99.24%, and 0.77% for fast walking, and 82.49%, 99.83%, and 0.17% for running, respectively. The evaluation shows that the proposed method is effective in reducing errors in HR estimation from PPG signals with motion artifacts in intensive motion situations such as fast walking and running. MDPI 2020-03-09 /pmc/articles/PMC7085621/ /pubmed/32182772 http://dx.doi.org/10.3390/s20051493 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Lee, Jongshill Kim, Minseong Park, Hoon-Ki Kim, In Young Motion Artifact Reduction in Wearable Photoplethysmography Based on Multi-Channel Sensors with Multiple Wavelengths |
title | Motion Artifact Reduction in Wearable Photoplethysmography Based on Multi-Channel Sensors with Multiple Wavelengths |
title_full | Motion Artifact Reduction in Wearable Photoplethysmography Based on Multi-Channel Sensors with Multiple Wavelengths |
title_fullStr | Motion Artifact Reduction in Wearable Photoplethysmography Based on Multi-Channel Sensors with Multiple Wavelengths |
title_full_unstemmed | Motion Artifact Reduction in Wearable Photoplethysmography Based on Multi-Channel Sensors with Multiple Wavelengths |
title_short | Motion Artifact Reduction in Wearable Photoplethysmography Based on Multi-Channel Sensors with Multiple Wavelengths |
title_sort | motion artifact reduction in wearable photoplethysmography based on multi-channel sensors with multiple wavelengths |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7085621/ https://www.ncbi.nlm.nih.gov/pubmed/32182772 http://dx.doi.org/10.3390/s20051493 |
work_keys_str_mv | AT leejongshill motionartifactreductioninwearablephotoplethysmographybasedonmultichannelsensorswithmultiplewavelengths AT kimminseong motionartifactreductioninwearablephotoplethysmographybasedonmultichannelsensorswithmultiplewavelengths AT parkhoonki motionartifactreductioninwearablephotoplethysmographybasedonmultichannelsensorswithmultiplewavelengths AT kiminyoung motionartifactreductioninwearablephotoplethysmographybasedonmultichannelsensorswithmultiplewavelengths |