Cargando…

Motion Artifact Reduction in Wearable Photoplethysmography Based on Multi-Channel Sensors with Multiple Wavelengths

Photoplethysmography (PPG) is an easy and convenient method by which to measure heart rate (HR). However, PPG signals that optically measure volumetric changes in blood are not robust to motion artifacts. In this paper, we develop a PPG measuring system based on multi-channel sensors with multiple w...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Jongshill, Kim, Minseong, Park, Hoon-Ki, Kim, In Young
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7085621/
https://www.ncbi.nlm.nih.gov/pubmed/32182772
http://dx.doi.org/10.3390/s20051493
_version_ 1783508973879558144
author Lee, Jongshill
Kim, Minseong
Park, Hoon-Ki
Kim, In Young
author_facet Lee, Jongshill
Kim, Minseong
Park, Hoon-Ki
Kim, In Young
author_sort Lee, Jongshill
collection PubMed
description Photoplethysmography (PPG) is an easy and convenient method by which to measure heart rate (HR). However, PPG signals that optically measure volumetric changes in blood are not robust to motion artifacts. In this paper, we develop a PPG measuring system based on multi-channel sensors with multiple wavelengths and propose a motion artifact reduction algorithm using independent component analysis (ICA). We also propose a truncated singular value decomposition for 12-channel PPG signals, which contain direction and depth information measured using the developed multi-channel PPG measurement system. The performance of the proposed method is evaluated against the R-peaks of an electrocardiogram in terms of sensitivity (Se), positive predictive value (PPV), and failed detection rate (FDR). The experimental results show that Se, PPV, and FDR were 99%, 99.55%, and 0.45% for walking, 96.28%, 99.24%, and 0.77% for fast walking, and 82.49%, 99.83%, and 0.17% for running, respectively. The evaluation shows that the proposed method is effective in reducing errors in HR estimation from PPG signals with motion artifacts in intensive motion situations such as fast walking and running.
format Online
Article
Text
id pubmed-7085621
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-70856212020-04-21 Motion Artifact Reduction in Wearable Photoplethysmography Based on Multi-Channel Sensors with Multiple Wavelengths Lee, Jongshill Kim, Minseong Park, Hoon-Ki Kim, In Young Sensors (Basel) Article Photoplethysmography (PPG) is an easy and convenient method by which to measure heart rate (HR). However, PPG signals that optically measure volumetric changes in blood are not robust to motion artifacts. In this paper, we develop a PPG measuring system based on multi-channel sensors with multiple wavelengths and propose a motion artifact reduction algorithm using independent component analysis (ICA). We also propose a truncated singular value decomposition for 12-channel PPG signals, which contain direction and depth information measured using the developed multi-channel PPG measurement system. The performance of the proposed method is evaluated against the R-peaks of an electrocardiogram in terms of sensitivity (Se), positive predictive value (PPV), and failed detection rate (FDR). The experimental results show that Se, PPV, and FDR were 99%, 99.55%, and 0.45% for walking, 96.28%, 99.24%, and 0.77% for fast walking, and 82.49%, 99.83%, and 0.17% for running, respectively. The evaluation shows that the proposed method is effective in reducing errors in HR estimation from PPG signals with motion artifacts in intensive motion situations such as fast walking and running. MDPI 2020-03-09 /pmc/articles/PMC7085621/ /pubmed/32182772 http://dx.doi.org/10.3390/s20051493 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lee, Jongshill
Kim, Minseong
Park, Hoon-Ki
Kim, In Young
Motion Artifact Reduction in Wearable Photoplethysmography Based on Multi-Channel Sensors with Multiple Wavelengths
title Motion Artifact Reduction in Wearable Photoplethysmography Based on Multi-Channel Sensors with Multiple Wavelengths
title_full Motion Artifact Reduction in Wearable Photoplethysmography Based on Multi-Channel Sensors with Multiple Wavelengths
title_fullStr Motion Artifact Reduction in Wearable Photoplethysmography Based on Multi-Channel Sensors with Multiple Wavelengths
title_full_unstemmed Motion Artifact Reduction in Wearable Photoplethysmography Based on Multi-Channel Sensors with Multiple Wavelengths
title_short Motion Artifact Reduction in Wearable Photoplethysmography Based on Multi-Channel Sensors with Multiple Wavelengths
title_sort motion artifact reduction in wearable photoplethysmography based on multi-channel sensors with multiple wavelengths
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7085621/
https://www.ncbi.nlm.nih.gov/pubmed/32182772
http://dx.doi.org/10.3390/s20051493
work_keys_str_mv AT leejongshill motionartifactreductioninwearablephotoplethysmographybasedonmultichannelsensorswithmultiplewavelengths
AT kimminseong motionartifactreductioninwearablephotoplethysmographybasedonmultichannelsensorswithmultiplewavelengths
AT parkhoonki motionartifactreductioninwearablephotoplethysmographybasedonmultichannelsensorswithmultiplewavelengths
AT kiminyoung motionartifactreductioninwearablephotoplethysmographybasedonmultichannelsensorswithmultiplewavelengths