Cargando…
Design of a Fully Integrated Inductive Coupling System: A Discrete Approach Towards Sensing Ventricular Pressure
In this paper, an alternative strategy for the design of a bidirectional inductive power transfer (IPT) module, intended for the continuous monitoring of cardiac pressure, is presented. This new integrated implantable medical device (IMD) was designed including a precise ventricular pressure sensor,...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7085681/ https://www.ncbi.nlm.nih.gov/pubmed/32164304 http://dx.doi.org/10.3390/s20051525 |
_version_ | 1783508987927330816 |
---|---|
author | Hernández Sebastián, Natiely Villa Villaseñor, Noé Renero-Carrillo, Francisco-Javier Díaz Alonso, Daniela Calleja Arriaga, Wilfrido |
author_facet | Hernández Sebastián, Natiely Villa Villaseñor, Noé Renero-Carrillo, Francisco-Javier Díaz Alonso, Daniela Calleja Arriaga, Wilfrido |
author_sort | Hernández Sebastián, Natiely |
collection | PubMed |
description | In this paper, an alternative strategy for the design of a bidirectional inductive power transfer (IPT) module, intended for the continuous monitoring of cardiac pressure, is presented. This new integrated implantable medical device (IMD) was designed including a precise ventricular pressure sensor, where the available implanting room is restricted to a 1.8 × 1.8 cm(2) area. This work considers a robust magnetic coupling between an external reading coil and the implantable module: a three-dimensional inductor and a touch mode capacitive pressure sensor (TMCPS) set. In this approach, the coupling modules were modelled as RCL circuits tuned at a 13.56 MHz frequency. The analytical design was validated by means of Comsol Multiphysics, CoventorWare, and ANSYS HFSS software tools. A power transmission efficiency (PTE) of 94% was achieved through a 3.5 cm-thick biological tissue, based on high magnitudes for the inductance (L) and quality factor (Q) components. A specific absorption rate (SAR) of less than 1.6 W/Kg was attained, which suggests that this IPT system can be implemented in a safe way, according to IEEE C95.1 safety guidelines. The set of inductor and capacitor integrated arrays were designed over a very thin polyimide film, where the 3D coil was 18 mm in diameter and approximately 50% reduced in size, considering any conventional counterpart. Finally, this new approach for the IMD was under development using low-cost thin film manufacturing technologies for flexible electronics. Meanwhile, as an alternative test, this novel system was fabricated using a discrete printed circuit board (PCB) approach, where preliminary electromagnetic characterization demonstrates the viability of this bidirectional IPT design. |
format | Online Article Text |
id | pubmed-7085681 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-70856812020-04-21 Design of a Fully Integrated Inductive Coupling System: A Discrete Approach Towards Sensing Ventricular Pressure Hernández Sebastián, Natiely Villa Villaseñor, Noé Renero-Carrillo, Francisco-Javier Díaz Alonso, Daniela Calleja Arriaga, Wilfrido Sensors (Basel) Article In this paper, an alternative strategy for the design of a bidirectional inductive power transfer (IPT) module, intended for the continuous monitoring of cardiac pressure, is presented. This new integrated implantable medical device (IMD) was designed including a precise ventricular pressure sensor, where the available implanting room is restricted to a 1.8 × 1.8 cm(2) area. This work considers a robust magnetic coupling between an external reading coil and the implantable module: a three-dimensional inductor and a touch mode capacitive pressure sensor (TMCPS) set. In this approach, the coupling modules were modelled as RCL circuits tuned at a 13.56 MHz frequency. The analytical design was validated by means of Comsol Multiphysics, CoventorWare, and ANSYS HFSS software tools. A power transmission efficiency (PTE) of 94% was achieved through a 3.5 cm-thick biological tissue, based on high magnitudes for the inductance (L) and quality factor (Q) components. A specific absorption rate (SAR) of less than 1.6 W/Kg was attained, which suggests that this IPT system can be implemented in a safe way, according to IEEE C95.1 safety guidelines. The set of inductor and capacitor integrated arrays were designed over a very thin polyimide film, where the 3D coil was 18 mm in diameter and approximately 50% reduced in size, considering any conventional counterpart. Finally, this new approach for the IMD was under development using low-cost thin film manufacturing technologies for flexible electronics. Meanwhile, as an alternative test, this novel system was fabricated using a discrete printed circuit board (PCB) approach, where preliminary electromagnetic characterization demonstrates the viability of this bidirectional IPT design. MDPI 2020-03-10 /pmc/articles/PMC7085681/ /pubmed/32164304 http://dx.doi.org/10.3390/s20051525 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Hernández Sebastián, Natiely Villa Villaseñor, Noé Renero-Carrillo, Francisco-Javier Díaz Alonso, Daniela Calleja Arriaga, Wilfrido Design of a Fully Integrated Inductive Coupling System: A Discrete Approach Towards Sensing Ventricular Pressure |
title | Design of a Fully Integrated Inductive Coupling System: A Discrete Approach Towards Sensing Ventricular Pressure |
title_full | Design of a Fully Integrated Inductive Coupling System: A Discrete Approach Towards Sensing Ventricular Pressure |
title_fullStr | Design of a Fully Integrated Inductive Coupling System: A Discrete Approach Towards Sensing Ventricular Pressure |
title_full_unstemmed | Design of a Fully Integrated Inductive Coupling System: A Discrete Approach Towards Sensing Ventricular Pressure |
title_short | Design of a Fully Integrated Inductive Coupling System: A Discrete Approach Towards Sensing Ventricular Pressure |
title_sort | design of a fully integrated inductive coupling system: a discrete approach towards sensing ventricular pressure |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7085681/ https://www.ncbi.nlm.nih.gov/pubmed/32164304 http://dx.doi.org/10.3390/s20051525 |
work_keys_str_mv | AT hernandezsebastiannatiely designofafullyintegratedinductivecouplingsystemadiscreteapproachtowardssensingventricularpressure AT villavillasenornoe designofafullyintegratedinductivecouplingsystemadiscreteapproachtowardssensingventricularpressure AT renerocarrillofranciscojavier designofafullyintegratedinductivecouplingsystemadiscreteapproachtowardssensingventricularpressure AT diazalonsodaniela designofafullyintegratedinductivecouplingsystemadiscreteapproachtowardssensingventricularpressure AT callejaarriagawilfrido designofafullyintegratedinductivecouplingsystemadiscreteapproachtowardssensingventricularpressure |