Cargando…
Design and Calibration of an Instrumented Seat Post to Measure Sitting Loads While Cycling
Traditional instrumented seat posts determine context-induced seat loads to analyze damping properties. This paper presents an enhanced instrumented seat post able to measure all six load components to resolve user-induced seat loads. User-induced cycling loads consist of all loads the user applies...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7085704/ https://www.ncbi.nlm.nih.gov/pubmed/32138310 http://dx.doi.org/10.3390/s20051384 |
_version_ | 1783508993706033152 |
---|---|
author | Sien, Dieltiens Jordi, D’hondt Juwet, Marc Shariatmadar, Keivan Versteyhe, Mark |
author_facet | Sien, Dieltiens Jordi, D’hondt Juwet, Marc Shariatmadar, Keivan Versteyhe, Mark |
author_sort | Sien, Dieltiens |
collection | PubMed |
description | Traditional instrumented seat posts determine context-induced seat loads to analyze damping properties. This paper presents an enhanced instrumented seat post able to measure all six load components to resolve user-induced seat loads. User-induced cycling loads consist of all loads the user applies to the bicycle during cycling and is measured at the steer stem, the seat post, and the pedals. Seat loads are essentially uncharted territory, as most studies only address pedal loading to study cycling technique. In this paper, a conventional seat post is redesigned by equipping it with a u-shaped component and strain gauges. The instrumented seat post is straightforward thanks to (i) the simple design, (ii) the gravitational calibration method, and (iii) the permitted clearance on the strain gauge alignment. Analyzing mean seat loading in function of the pedal cycle can provide extra insights into cycling technique and the related injuries. It is an interesting addition to the universally adopted method of utilizing singular pedal loads. |
format | Online Article Text |
id | pubmed-7085704 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-70857042020-04-21 Design and Calibration of an Instrumented Seat Post to Measure Sitting Loads While Cycling Sien, Dieltiens Jordi, D’hondt Juwet, Marc Shariatmadar, Keivan Versteyhe, Mark Sensors (Basel) Article Traditional instrumented seat posts determine context-induced seat loads to analyze damping properties. This paper presents an enhanced instrumented seat post able to measure all six load components to resolve user-induced seat loads. User-induced cycling loads consist of all loads the user applies to the bicycle during cycling and is measured at the steer stem, the seat post, and the pedals. Seat loads are essentially uncharted territory, as most studies only address pedal loading to study cycling technique. In this paper, a conventional seat post is redesigned by equipping it with a u-shaped component and strain gauges. The instrumented seat post is straightforward thanks to (i) the simple design, (ii) the gravitational calibration method, and (iii) the permitted clearance on the strain gauge alignment. Analyzing mean seat loading in function of the pedal cycle can provide extra insights into cycling technique and the related injuries. It is an interesting addition to the universally adopted method of utilizing singular pedal loads. MDPI 2020-03-03 /pmc/articles/PMC7085704/ /pubmed/32138310 http://dx.doi.org/10.3390/s20051384 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Sien, Dieltiens Jordi, D’hondt Juwet, Marc Shariatmadar, Keivan Versteyhe, Mark Design and Calibration of an Instrumented Seat Post to Measure Sitting Loads While Cycling |
title | Design and Calibration of an Instrumented Seat Post to Measure Sitting Loads While Cycling |
title_full | Design and Calibration of an Instrumented Seat Post to Measure Sitting Loads While Cycling |
title_fullStr | Design and Calibration of an Instrumented Seat Post to Measure Sitting Loads While Cycling |
title_full_unstemmed | Design and Calibration of an Instrumented Seat Post to Measure Sitting Loads While Cycling |
title_short | Design and Calibration of an Instrumented Seat Post to Measure Sitting Loads While Cycling |
title_sort | design and calibration of an instrumented seat post to measure sitting loads while cycling |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7085704/ https://www.ncbi.nlm.nih.gov/pubmed/32138310 http://dx.doi.org/10.3390/s20051384 |
work_keys_str_mv | AT siendieltiens designandcalibrationofaninstrumentedseatposttomeasuresittingloadswhilecycling AT jordidhondt designandcalibrationofaninstrumentedseatposttomeasuresittingloadswhilecycling AT juwetmarc designandcalibrationofaninstrumentedseatposttomeasuresittingloadswhilecycling AT shariatmadarkeivan designandcalibrationofaninstrumentedseatposttomeasuresittingloadswhilecycling AT versteyhemark designandcalibrationofaninstrumentedseatposttomeasuresittingloadswhilecycling |