Valve-Actuator-Integrated Reference Electrode for an Ultra-Long-Life Rumen pH Sensor

We demonstrated a newly developed Ag/AgCl reference electrode- with a valve-actuator for two years or longer rumen pH monitoring. Previous studies on pH sensors reported that the short lifetime of Ag/AgCl reference electrodes is caused by an outflow of internal electrolyte. We introduced a valve-act...

Descripción completa

Detalles Bibliográficos
Autores principales: Higuchi, Shogo, Okada, Hironao, Takamatsu, Seiichi, Itoh, Toshihiro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7085735/
https://www.ncbi.nlm.nih.gov/pubmed/32106461
http://dx.doi.org/10.3390/s20051249
_version_ 1783509001035579392
author Higuchi, Shogo
Okada, Hironao
Takamatsu, Seiichi
Itoh, Toshihiro
author_facet Higuchi, Shogo
Okada, Hironao
Takamatsu, Seiichi
Itoh, Toshihiro
author_sort Higuchi, Shogo
collection PubMed
description We demonstrated a newly developed Ag/AgCl reference electrode- with a valve-actuator for two years or longer rumen pH monitoring. Previous studies on pH sensors reported that the short lifetime of Ag/AgCl reference electrodes is caused by an outflow of internal electrolyte. We introduced a valve-actuator into a liquid junction to reduce the outflow by intermittent measurement. The results indicated that the potential change when switching the liquid junction was less than 0.5 mV and its response time was less than 0.083 s. In the 24-h potential measurement with the valve-actuator-integrated reference electrode (VAIRE), the valve was actuated once every hour, and the standard deviation of the potential was 0.29 mV. The lifetime of the VAIRE was estimated at 2.0 years calculating from an electrolyte outflow, which is significantly longer than that of conventional reference electrodes. A pH sensor using the VAIRE was estimated to operate for 2.0 years with the pH error ≤0.1, which meets the requirement of cows’ rumen pH monitoring.
format Online
Article
Text
id pubmed-7085735
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-70857352020-03-25 Valve-Actuator-Integrated Reference Electrode for an Ultra-Long-Life Rumen pH Sensor Higuchi, Shogo Okada, Hironao Takamatsu, Seiichi Itoh, Toshihiro Sensors (Basel) Article We demonstrated a newly developed Ag/AgCl reference electrode- with a valve-actuator for two years or longer rumen pH monitoring. Previous studies on pH sensors reported that the short lifetime of Ag/AgCl reference electrodes is caused by an outflow of internal electrolyte. We introduced a valve-actuator into a liquid junction to reduce the outflow by intermittent measurement. The results indicated that the potential change when switching the liquid junction was less than 0.5 mV and its response time was less than 0.083 s. In the 24-h potential measurement with the valve-actuator-integrated reference electrode (VAIRE), the valve was actuated once every hour, and the standard deviation of the potential was 0.29 mV. The lifetime of the VAIRE was estimated at 2.0 years calculating from an electrolyte outflow, which is significantly longer than that of conventional reference electrodes. A pH sensor using the VAIRE was estimated to operate for 2.0 years with the pH error ≤0.1, which meets the requirement of cows’ rumen pH monitoring. MDPI 2020-02-25 /pmc/articles/PMC7085735/ /pubmed/32106461 http://dx.doi.org/10.3390/s20051249 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Higuchi, Shogo
Okada, Hironao
Takamatsu, Seiichi
Itoh, Toshihiro
Valve-Actuator-Integrated Reference Electrode for an Ultra-Long-Life Rumen pH Sensor
title Valve-Actuator-Integrated Reference Electrode for an Ultra-Long-Life Rumen pH Sensor
title_full Valve-Actuator-Integrated Reference Electrode for an Ultra-Long-Life Rumen pH Sensor
title_fullStr Valve-Actuator-Integrated Reference Electrode for an Ultra-Long-Life Rumen pH Sensor
title_full_unstemmed Valve-Actuator-Integrated Reference Electrode for an Ultra-Long-Life Rumen pH Sensor
title_short Valve-Actuator-Integrated Reference Electrode for an Ultra-Long-Life Rumen pH Sensor
title_sort valve-actuator-integrated reference electrode for an ultra-long-life rumen ph sensor
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7085735/
https://www.ncbi.nlm.nih.gov/pubmed/32106461
http://dx.doi.org/10.3390/s20051249
work_keys_str_mv AT higuchishogo valveactuatorintegratedreferenceelectrodeforanultralongliferumenphsensor
AT okadahironao valveactuatorintegratedreferenceelectrodeforanultralongliferumenphsensor
AT takamatsuseiichi valveactuatorintegratedreferenceelectrodeforanultralongliferumenphsensor
AT itohtoshihiro valveactuatorintegratedreferenceelectrodeforanultralongliferumenphsensor