Cargando…
Valve-Actuator-Integrated Reference Electrode for an Ultra-Long-Life Rumen pH Sensor
We demonstrated a newly developed Ag/AgCl reference electrode- with a valve-actuator for two years or longer rumen pH monitoring. Previous studies on pH sensors reported that the short lifetime of Ag/AgCl reference electrodes is caused by an outflow of internal electrolyte. We introduced a valve-act...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7085735/ https://www.ncbi.nlm.nih.gov/pubmed/32106461 http://dx.doi.org/10.3390/s20051249 |
_version_ | 1783509001035579392 |
---|---|
author | Higuchi, Shogo Okada, Hironao Takamatsu, Seiichi Itoh, Toshihiro |
author_facet | Higuchi, Shogo Okada, Hironao Takamatsu, Seiichi Itoh, Toshihiro |
author_sort | Higuchi, Shogo |
collection | PubMed |
description | We demonstrated a newly developed Ag/AgCl reference electrode- with a valve-actuator for two years or longer rumen pH monitoring. Previous studies on pH sensors reported that the short lifetime of Ag/AgCl reference electrodes is caused by an outflow of internal electrolyte. We introduced a valve-actuator into a liquid junction to reduce the outflow by intermittent measurement. The results indicated that the potential change when switching the liquid junction was less than 0.5 mV and its response time was less than 0.083 s. In the 24-h potential measurement with the valve-actuator-integrated reference electrode (VAIRE), the valve was actuated once every hour, and the standard deviation of the potential was 0.29 mV. The lifetime of the VAIRE was estimated at 2.0 years calculating from an electrolyte outflow, which is significantly longer than that of conventional reference electrodes. A pH sensor using the VAIRE was estimated to operate for 2.0 years with the pH error ≤0.1, which meets the requirement of cows’ rumen pH monitoring. |
format | Online Article Text |
id | pubmed-7085735 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-70857352020-03-25 Valve-Actuator-Integrated Reference Electrode for an Ultra-Long-Life Rumen pH Sensor Higuchi, Shogo Okada, Hironao Takamatsu, Seiichi Itoh, Toshihiro Sensors (Basel) Article We demonstrated a newly developed Ag/AgCl reference electrode- with a valve-actuator for two years or longer rumen pH monitoring. Previous studies on pH sensors reported that the short lifetime of Ag/AgCl reference electrodes is caused by an outflow of internal electrolyte. We introduced a valve-actuator into a liquid junction to reduce the outflow by intermittent measurement. The results indicated that the potential change when switching the liquid junction was less than 0.5 mV and its response time was less than 0.083 s. In the 24-h potential measurement with the valve-actuator-integrated reference electrode (VAIRE), the valve was actuated once every hour, and the standard deviation of the potential was 0.29 mV. The lifetime of the VAIRE was estimated at 2.0 years calculating from an electrolyte outflow, which is significantly longer than that of conventional reference electrodes. A pH sensor using the VAIRE was estimated to operate for 2.0 years with the pH error ≤0.1, which meets the requirement of cows’ rumen pH monitoring. MDPI 2020-02-25 /pmc/articles/PMC7085735/ /pubmed/32106461 http://dx.doi.org/10.3390/s20051249 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Higuchi, Shogo Okada, Hironao Takamatsu, Seiichi Itoh, Toshihiro Valve-Actuator-Integrated Reference Electrode for an Ultra-Long-Life Rumen pH Sensor |
title | Valve-Actuator-Integrated Reference Electrode for an Ultra-Long-Life Rumen pH Sensor |
title_full | Valve-Actuator-Integrated Reference Electrode for an Ultra-Long-Life Rumen pH Sensor |
title_fullStr | Valve-Actuator-Integrated Reference Electrode for an Ultra-Long-Life Rumen pH Sensor |
title_full_unstemmed | Valve-Actuator-Integrated Reference Electrode for an Ultra-Long-Life Rumen pH Sensor |
title_short | Valve-Actuator-Integrated Reference Electrode for an Ultra-Long-Life Rumen pH Sensor |
title_sort | valve-actuator-integrated reference electrode for an ultra-long-life rumen ph sensor |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7085735/ https://www.ncbi.nlm.nih.gov/pubmed/32106461 http://dx.doi.org/10.3390/s20051249 |
work_keys_str_mv | AT higuchishogo valveactuatorintegratedreferenceelectrodeforanultralongliferumenphsensor AT okadahironao valveactuatorintegratedreferenceelectrodeforanultralongliferumenphsensor AT takamatsuseiichi valveactuatorintegratedreferenceelectrodeforanultralongliferumenphsensor AT itohtoshihiro valveactuatorintegratedreferenceelectrodeforanultralongliferumenphsensor |