Comparison of five diagnostic methods for the detection of rotavirus antigens in calf faeces

Immunoelectroosmophoresis, complement fixation, immunofluorescence on inoculated cell cultures, electron microscopy, and an enzyme-linked immunosorbent assay were compared for the detection of rotavirus in faecal samples from calves. Rotavirus particles could be detected in 39 out of 98 faecal sampl...

Descripción completa

Detalles Bibliográficos
Autores principales: Ellens, D. J., de Leeuw, P. W., Straver, P. J., van Balken, J. A. M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer-Verlag 1978
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7086822/
https://www.ncbi.nlm.nih.gov/pubmed/214679
http://dx.doi.org/10.1007/BF02121145
Descripción
Sumario:Immunoelectroosmophoresis, complement fixation, immunofluorescence on inoculated cell cultures, electron microscopy, and an enzyme-linked immunosorbent assay were compared for the detection of rotavirus in faecal samples from calves. Rotavirus particles could be detected in 39 out of 98 faecal samples by electron microscopy. Immunofluorescence, complement fixation, and immunoelectroosmophoresis detected rotavirus antigens in 39, 42, and 30 samples, respectively. The enzyme-linked immunosorbent assay demonstrated rotavirus antigens in 49 faecal samples. The assay is not only sensitive but also simple to perform and suitable for large-scale testing.